- CARE OF YOUR REVERSE OSMOSIS SYSTEM -
TUBING CONNECTION (all push- in fitting locations)
This RO system includes
tubing connection at most locations. If working with the fittings, do the following.
Connection (Figure 14):
1.Use a sharp cutter or knife to cut the end of tubing square.
2.Inspect the end (about 1") of the tubing to be sure
there are no nicks, scratches or other rough spots. If
needed, cut the tubing again.
3.Push tubing through the collet and all the way into
fitting. Full engagement is 11/16" for 1/4" tubing, and 3/4" for 3/8" tubing.
If using tubing other than tubing supplied with the
system, be sure it is of high quality, exact size and
roundness with a smooth surface.
Tubing correctly cut and connected
! | m | 1 |
I | CAUTION | I |
IDO NOT USE VINEGAR OR OTtIER ACID BASED I
ICLEANEI_,SON THIS F,OSYSTEM.THEY WILL I I r)EGRADESOMEI_,OSYSTEMPAP,TS.ALWAYS I
I | USE SOAP AN[)WATER. | I |
! | m | m.I |
This reverse osmosis system contains a replaceable treatment component critical to the efficiency of the
system. Replacement of the reverse osmosis compo- I I nent should be with one of identical specifications,
as defined by the manufacturer; to assure the same I
efficiency and contaminant reduction performance.
! | _ | m.I |
AUTOMATIC SHUTOFF SERVICE
If the shutoff assembly requires service, be sure to
reassemble parts exactly as shown in Figure 16.
cut tubing s_uare
II
I
end of tubing round and smooth, with no cuts,
nicks or fiat spots
Figure 14
collet ...__
_ 11/16" (1/4" tubing)
'engagement
_ 3/4" (3/8" tubing)
screw (4)
SHUTOFF
ASSEMBLY
diaphragm
plunger |
To Disconnect Tubing (Figure 15): Push the collet in- ward and hold with a finger while pulling the tubing out.
Changing Collet and O-ring (Figure 15):
1.With a small screwdriver remove the collet and o-
ring from the fitting. Be careful not to scratch the in- ternal walls of the collet port.
2.Be sure the port is clean, then lubricate and insert the
3.Push the collet inward until it locks in place.
Replacing collet and
collet (depress to | Push | |
bottom | of port, then | |
remove tubing) | follow | with collet. |
tubi_/_
| spring | |
| valve | |
spacer ring | check | |
ball | ||
| ||
diaphragm |
|
collet
Figure 15 | Figure 16 |
| 16 |
Problems, Questions? Call