Kenmore 625.385720, 625.385700 Install Faucet, Assemble Faucet Ultrafilter, UltraFilter

Page 7

- STEP 3: INSTALL FAUCET (cont.)-

B. ASSEMBLE FAUCET

ULTRAFILTER 150

1. Loosely assemble the base, spacer, washer and plastic nut onto the faucet stud.

2. Route the 1/4" red tubing through the sink or

countertop hole and connect to 1/4" barb on faucet.

3.Route the 3/8" black tubing through sink or the

countertop hole and connect to 3/8" barb on faucet.

4.Attach the 3/8" blue tubing to the faucet stud us- ing the tubing adaptor.

5.Lower faucet into place on the countertop, on the

underside of the countertop or sink slide the slotted

washer into place and tighten plastic nut. Tighten the nut so the faucet cannot move, but do not over- tighten.

UltraFilter 150

faucet & spout

H hole in sink or

b__i_bers

slotted washer _ (_

""

 

washer -.......(_

 

 

 

 

hex nut _

(_

tubing

adaptor

 

(connects

to

 

 

 

1/4"

red tubing

 

/bottom

of stud)

 

 

 

 

from

RO drain

 

3/8" black

tubing to

(connect to 1/4"

 

drain

point

(connect

barb on faucet)

 

to 3/8"

barb on faucet)

/

3/8" blue tubing (connect to stud on faucet)

Figure 6

7

Problems, Questions? Call 1-800-426-9345 Kenmore Water Line

Image 7
Contents UltraFilter 150 UltraFilter 350 Model noExcept filter Cartridges and R. O. membrane WarrantySafety Guides Full Warranty on Reverse Osmosis Drinking Water SystemBefore YOU Begin to Install the RO System Table of ContentsWhat Your Reverse Osmosis System will do Steps to Install Where to Install the RO SystemTools and Materials Needed Water Supply Fitting Optional Pipe Fittings Install Cold Water Supply FittingCheck Comply Codes asInstall Faucet Install Drain AdapterPrepare Mounting Hole Assemble Faucet Ultrafilter Install FaucetUltraFilter Tubing RO System InstallFaucet Assemble FaucetFaucet Electronics Install RO AssemblyTypical Undersink Installation Install Storage TANK, Make Remaining Tubing ConnectionsConnect Drain TUBING, Faucet to Pressure Testing SANITIZING, Pressure Testing & PurgingSanitizing Faucet HOW Your Reverse Osmosis System WorksFlow Control Itl Prefilter and Post Filter Cartridges Care of Your Reverse Osmosis SystemRO Membrane Cartridge USE Soap Anwater Automatic Shutoff ServiceChanging Collet and O-ring Figure Correction Other TroubleshootingMetric Dimensions and SpecificationsRemote RO Installation Remote Installation LocationsStorage tank not shown 19i 812 Repair PartsKey Key Part Description of Part NumberProblems, Questions? Call 1-800-426-9345 Kenmore Water Line Problems, Questions? Call 1-800-426-9345 Kenmore Water Line Matter who made it, no matter who sold it Your Home