Kenmore 625.385720, 625.385700 owner manual Install RO Assembly, Faucet Electronics

Page 9

- STEP 3: INSTALL FAUCET (cont.)-

UltraFilter 350

channel

locking tabs

valve lever

FAUCET ELECTRONICS

The faucet will measure the length of time the filters

have been installed (6 months). The faucet has an in-

dicator LED that flashes to inform you of the status of the filter.

Green - Filter is good. Red - Filters need replacing.

In order to reset the monitor time feature, the battery

should be removed for a minimum of five seconds and then reinserted.

The battery needs to be replaced when indicater LEDs no longer light. Use only 3 volt sealed lithium

batteries. Improper placement of battery could dam-

age electronics. Use care when inserting battery to align it correctly.

To change the battery, pull the spout and bezel from the faucet base. The bezel will stay on the spout. Pinch the two tabs (under bezel on faucet) with one hand and with the other, pull up on the knob.

Change battery. Assemble the the knob, and spout and bezel back onto the faucet base.

Figure 8

- STEP 4: INSTALL RO ASSEMBLY -

Hang the assembly on the included hanger washers, or lay on the cabinet floor, as desired.

1.Refer to Figure 9 for wall mounting. Hold the as- sembly up to the wall surface and mark locations for

the hanger

washers.

Distance

needed

is 7.2"

(approx.

7-7/32")

apart.

 

 

 

2.Install hanger washers at least 15-1/2" up from the cabinet floor, allowing room to remove sumps from

filter heads. Wood screws are provided, or obtain

other fasteners as needed.

15-1/2" min.

up from floor

Figure 9

9

Problems, Questions? Call 1-800-426-9345 Kenmore Water Line

Image 9
Contents UltraFilter 150 UltraFilter 350 Model noSafety Guides WarrantyFull Warranty on Reverse Osmosis Drinking Water System Except filter Cartridges and R. O. membraneTable of Contents Before YOU Begin to Install the RO SystemWhat Your Reverse Osmosis System will do Where to Install the RO System Steps to InstallTools and Materials Needed Check Comply Install Cold Water Supply FittingCodes as Water Supply Fitting Optional Pipe FittingsInstall Drain Adapter Install FaucetPrepare Mounting Hole Install Faucet Assemble Faucet UltrafilterUltraFilter Faucet InstallAssemble Faucet Tubing RO SystemFaucet Electronics Install RO AssemblyInstall Storage TANK, Make Remaining Tubing Connections Typical Undersink InstallationConnect Drain TUBING, Faucet to SANITIZING, Pressure Testing & Purging Pressure TestingSanitizing HOW Your Reverse Osmosis System Works FaucetFlow Control Itl Prefilter and Post Filter Cartridges Care of Your Reverse Osmosis SystemRO Membrane Cartridge Automatic Shutoff Service USE Soap AnwaterChanging Collet and O-ring Figure Correction Other TroubleshootingMetric Dimensions and SpecificationsRemote Installation Locations Remote RO InstallationStorage tank not shown 19i 812 Repair PartsKey Key Part Description of Part NumberProblems, Questions? Call 1-800-426-9345 Kenmore Water Line Problems, Questions? Call 1-800-426-9345 Kenmore Water Line Matter who made it, no matter who sold it Your Home