Kenmore 625.38575 owner manual Prefilter and Post Filter Cartridges, Poetfilter

Page 12

- CARE OF YOUR REVERSE OSMOSIS SYSTEM -

PREFILTER AND POST FILTER CARTRIDGES

You must replace the pref!lter cartridge often to pro- tect the RO membrane from being destroyed by chlorine,

and/or from plugging with sediments in your water

supply. If the water supply contains both chlorine

and sediments, replace the prefilter cartridge at least

every 6 months of product water use. Replace more

often than 6 months if it begins to plug with sedi- ments.

If the water has sediments only, with no chlorine, you may notice a slower making of product water as the

prefilter collects the sediments. When this occurs, re-

timer. (monitor models).

*Note: Use a lubricant approved for use on a potable water supply.

prefilter

cartridge (cartridge o- ring seals on this end)

place the prefilter cartridge. Also replace the post f!lter cartridge.

To replace the filter cartridges (see Figure 10):

/

RO Cartridge

(cartridge o-ring seals on this end

1.Turn off the water supply and open the RO faucet to relieve pressure.

2.Remove (turn to the left) both sumps from the filter

heads. Be careful...the sumps are full of water.

3.Remove and discard the inner cartridges in a prop- er manner. Flush the insides of the sumps with fresh

water. Do not lose the large o-ring seals.

4.Insert new cartridges with o-ring* seals towards

the top, and with lubricated* o- rings in place, turn to the right to reattach the sumps.

5.Remove and replace batteries to reset counter and

o-ring seal

poetfilter

cartridge

(cartridge o-ring seals on this end)

sump

Turn sumps in the direction of the arrow to remove. Turn oppo- site way to install and tighten.

Figure 10

12

Problems, Questions? Call 1-800-426-9345 Kenmore Water Line

Image 12
Contents Owners Manual Model noWarranty Safety GuidesExcept filter Cartridges and R. O. membrane Table of Contents Before YOU Begin to Install the RO SystemWhat Your Reverse Osmosis System will do Where to Install the RO System Steps to InstallTools and Materials Needed Install Cold Water Supply Fitting Water Supply Fitting Optional Pipe FittingsInstall Drain Adapter Install FaucetInstall RO AssemblyAssemble Faucet Install Storage TANK, Make Remaining Tubing Connections Connect Drain TUBING, Faucet to SANITIZING, Pressure Testing & Purging Pressure TestingHOW Your Reverse Osmosis System Works Reverse Osmosis Water Flow Schematic Care of Your Reverse Osmosis SystemPrefilter and Post Filter Cartridges PoetfilterRO Membrane Cartridge Automatic Shutoff Service PlungerReverse Osmosis System Care Guide Model noDimensions and Specifications MetricRemote Installation Locations Storage Tank not shownRepair Parts Key Part Description of Part Number KeyYour Home Our Home