Kenmore 625.38575 owner manual Automatic Shutoff Service, Plunger

Page 14

- CARE OF YOUR REVERSE OSMOSIS SYSTEM -

TUBING CONNECTION (all push- in fitting locations)

This RO system includes push-in fittings for quick

tubing connection at most locations. If working with the fittings, do the following.

Connection (Figure 12):

1.Use a sharp cutter or knife to cut the end of tubing square.

2.Inspect the end (about 1") of the tubing to be sure

there are no nicks, scratches or other rough spots. If

needed, cut the tubing again.

3.Push tubing through the collet and all the way into

fitting. Full engagement is 11/16" for 1/4" tubing, and 3/4" for 3/8" tubing.

If using tubing other than tubing supplied with the

system, be sure it is of high quality, exact size and

roundness with a smooth surface.

Tubing correctly cut and connected

!

m

1

I

CAUTION

I

IDO NOT USE VINEGAR OR OTHER ACID BASED I I CLEANERS ON THIS RO SYSTEM. THEY WILL I I DEGRADE SOME RO SYSTEM PARTS. ALWAYS I

I

USE SOAP

ANDWATER.

 

 

 

 

 

I

I

 

 

 

 

m

 

 

 

 

 

 

m.I

 

I

This

reverse

osmosis

system

contains

a replaceable

 

I

 

treatment component critical to the efficiency of the

 

I

system.

Replacement

of

the reverse osmosis

compo-

 

I

I

nent

should

be with

one

of

identical

specifications,

 

I

I

as defined

by

the manufacturer;

to assure

the same

I

I

efficiency

and

contaminant

reduction

performance.

 

I

I

 

 

 

 

_

 

 

 

 

 

 

m.I

 

AUTOMATIC SHUTOFF SERVICE

If the shutoff assembly requires service, be sure to

reassemble parts exactly as shown in Figure 14.

cut tubing s_uare

II

I

end of tubing round and smooth, with no cuts,

nicks or fiat spots

Figure 12

collet .__

_ 11/16" (1/4" tubing)

'engagement

Fg=- 3/4" (3/8" tubing)

screw (4)

SHUTOFF

ASSEMBLY

diaphragm

o-ring

plunger

To Disconnect Tubing (Figure 13): Push the collet in- ward and hold with a finger while pulling the tubing out.

Changing Collet and O-ring (Figure 13):

1.With a small screwdriver remove the collet and o-

ring from the fitting. Be careful not to scratch the in- ternal walls of the collet port.

2.Be sure the port is clean, then lubricate and insert the o-ring seal to the bottom of the port.

3.Push the collet inward until it locks in place.

Replacing collet and

o-ring seal

collet (depress to

Push o-ring seal into

bottom

of port, then

remove tubing)

follow

with collet.

_--_fitting

tubi_._

/

collet

 

spring

 

valve

spacer ring

check

ball

 

diaphragm

 

Figure 13

Figure 14

 

14

Problems, Questions? Call 1-800-426-9345 Kenmore Water Line

Image 14
Contents Owners Manual Model noExcept filter Cartridges and R. O. membrane WarrantySafety Guides What Your Reverse Osmosis System will do Table of ContentsBefore YOU Begin to Install the RO System Tools and Materials Needed Where to Install the RO SystemSteps to Install Install Cold Water Supply Fitting Water Supply Fitting Optional Pipe FittingsInstall Drain Adapter Install FaucetAssemble Faucet InstallRO Assembly Install Storage TANK, Make Remaining Tubing Connections Connect Drain TUBING, Faucet toSANITIZING, Pressure Testing & Purging Pressure TestingHOW Your Reverse Osmosis System Works Reverse Osmosis Water Flow Schematic Care of Your Reverse Osmosis SystemPrefilter and Post Filter Cartridges PoetfilterRO Membrane Cartridge Automatic Shutoff Service PlungerReverse Osmosis System Care Guide Model noDimensions and Specifications MetricRemote Installation Locations Storage Tank not shownRepair Parts Key Part Description of Part Number KeyYour Home Our Home

625.38575 specifications

The Kenmore 625.38575 is a highly regarded model in the line of portable air compressors, designed to meet the diverse needs of DIY enthusiasts and professionals alike. With a powerful performance and a range of features, this compressor stands out for its reliability and efficiency.

One of the main characteristics of the Kenmore 625.38575 is its robust motor, which typically operates at 1.5 HP. This ensures that the compressor can tackle a variety of tasks, from inflating tires to powering pneumatic tools. The oil-free pump design not only minimizes maintenance but also allows for a cleaner and quieter operation, making it ideal for indoor use or in residential areas where noise can be a concern.

The compressor offers a maximum pressure of around 125 PSI, which is sufficient for most applications. Additionally, the unit boasts a high volume output, with a flow rate close to 2.5 CFM at 90 PSI, allowing for quick recovery times and the ability to run multiple tools simultaneously without significant drops in pressure.

In terms of durability, the Kenmore 625.38575 features a reinforced frame and a sturdy handle for portability, ensuring that it can withstand the rigors of different job sites. The unit is also equipped with rubber feet to reduce vibrations and prevent slipping during operation.

Safety features are prominent in this model as well. The compressor includes an automatic shut-off function that prevents overheating and extends the life of the motor. The pressure gauge is easy to read, providing users with accurate pressure readings to adjust their settings as needed.

Another noteworthy aspect of the Kenmore 625.38575 is its user-friendly design. The onboard storage for accessories and hose makes it easy to keep everything organized and within reach. Overall, the Kenmore 625.38575 is an effective and versatile air compressor that delivers power and convenience, making it a popular choice for both home improvement projects and professional use. Its combination of efficiency, durability, and ease of use makes it a valuable tool in any workshop or garage.