english 8 Troubleshooting
Fault |
| Cause |
| Remedy |
Pressure drop | > | Air in the system | • Vent the system by | |
|
|
|
| operating the spray gun |
|
|
|
| several times at short |
|
|
|
| intervals. If necessary, |
|
|
|
| operate the cleaner for a |
|
|
|
| short time without the high- |
|
|
|
| pressure hose connected. |
| > High pressure nozzle blocked | • | Clean/replace the high | |
|
| worn |
| pressure nozzle |
| > Pressure control on the spray | • Set the required working | ||
|
| pipe is not set correctly |
| pressure |
| > | Detergent tank empty | • Top up detergent tank or | |
|
|
|
| set detergent metering to |
|
|
|
| “0” |
Pressure fluctuations | > | Pump draws in air (only | • Check that the suction set | |
|
| possible in suction mode) |
| is |
| > | Lack of water | • | Open water tap |
| > Water inlet hose is too long | • Use specified water inlet | ||
|
| or its |
| hose |
| > Lack of water caused by | • Clean the water filter in the | ||
|
| blocked water filter |
| water connection (never |
|
|
|
| work without water filter) |
| > Lack of water because max. | • | See instructions | |
|
| permissible suction height |
|
|
|
| has not been heeded |
|
|
|
|
|
| |
The motor does not start when | > | The plug is not inserted | • Check the plug, lead and | |
the cleaner is switched on |
| properly, i.e. there is no |
| switch and if necessary |
|
| current |
| have them replaced by a |
|
|
|
| trained electrician |
| > The mains fuse is switched | • Switch on the mains fuse | ||
|
| off |
|
|
When the cleaner is switched | > | The mains voltage is too low | • | Have the electrical |
on the motor buzzes without |
| or there is a phase failure. |
| connection checked |
starting | > The pump is blocked or | • Contact the Gerni customer | ||
| ||||
|
| frozen |
| service |
| > | Incorrect | • Use lead with correct cross | |
|
| length of the extension lead |
| section or length |
|
|
|
| |
The motor switches off | > | The overload protection | • Check that the mains | |
|
| has been activated due to |
| voltage and the cleaner |
|
| overheating or overloading of |
| voltage are the same. |
|
| the motor |
| Switch off the cleaner and |
|
|
|
| allow it to cool for at least 3 |
|
|
|
| minutes |
| > | • | Change the | |
|
|
|
| nozzle |
|
|
|
|
|
14 | 1) Options / model variants |