Nilfisk-Advance America 5 manual Further information, Recycling the cleaner

Page 16

POSEIDON 5

Fault

 

Cause

 

Remedy

english

 

 

 

No detergents drawn in

>

Injector is dirty or suction

Clean

 

 

 

hose is blocked

 

 

 

 

>

Detergent tank empty

Top up detergent tank

 

 

> The cap on the FlexoPower-

see chapter 4.6

 

 

 

Jet nozzle is not set to low

 

 

 

 

 

pressure

 

 

 

9 Further information

9.1Recycling the cleaner

Make the old cleaner unusable immediately.

1.Unplug the cleaner and cut the power cord.

Do not discard of electrical ap- pliances with household waste.

As specified in European Direc- tive 2002/96/EC on old electrical and electronic appliances, used electrical goods must be col- lected separately and recycled ecologically. Contact your local authorities or your nearest deal- er for further information.

9.2Guarantee

9.3EU Declaration of Conformity

Our general conditions of busi-

change as a result of technical

ness are applicable with regard

advances.

to the guarantee. Subject to

 

EU Declaration of Conformity

Product:

Type:

Description:

The design of the unit corresponds to the following pertinent regulations:

Applied harmonised standards:

Applied national standards and technical specifications:

Dipl. Ing. Wolfgang Nieuwkamp

Tests and approvals

High Pressure Cleaner

POSEIDON 5

230 V, 1~, 50 Hz, IP X5

400 V, 3~, 50 Hz, IP X5

EC Machine Directive 98/37/EEG EC Low-voltage Directive 73/23/EEG EC EMV Directive 2004/108/EEG

EN 12100, EN 60335-2-79

EN 55014-1, EN 55014-2, EN 61000-3-2

DIN EN 60335-2-79

ALTO Deutschland GmbH

Guido-Oberdorfer-Straße 2-8

D-89287 Bellenberg

Bellenberg, 2007-01-02

1) Options / model variants

15

Image 16 Contents
POSEIDONG45 Contents Important safety instructions English Symbols used to mark instructionsFor your own safety TransportMaintenance and repair TestingOperation Electrical equipmentUnloader valve DescriptionPurpose Before starting the cleaner Setting up the cleanerFill up detergent tank1 Machines with high pressure hose reelElectrical connection Connecting the water supplyUse Control / Operation ConnectionsPressure regulation Tornado LanceHigh pressure = clockwise + Low pressure = anticlockwise High pressure = MAX Low pressure = MIN.CHEMApplications and methods Vehicle Task Accessories Method After using the cleaner Task Accessories MethodSwitching off the cleaner Disconnecting supply lines Buildings and EquipmentMaintenance Checking the pump oil level Maintenance work 7.2.1 Cleaning water inlet FilterChanging the pump oil English 8 Troubleshooting Fault Cause RemedyGuarantee EU Declaration of Conformity Recycling the cleanerFurther information Technical Data PoseidonPoseidon 5 XT