Configures the DSP processing chain to swap the Left and Right internal channels, that is, the DSP Left Channel is fed from Right Channel input and the DSP Right Channel is fed from the Left Channel input. Note that this selection is active in all sources selected as Primary and Secondary (Failover) audio sources.
Click on this option to return to the Input/Output submenu.
Output
There are five controls under the heading “Output” and each will be explained in the order in which they appear in the menu:
Click on this option to return to the Input/Output submenu
Anlg Level (Analog Level)
Adjusts the master audio Output level for the analog outputs which appear on the rear panel XLR male connectors. This control adjusts both the left and right stereo channel simultaneously.
Right Trim
Allows a
AES Level (AES/EBU Level)
Adjusts the master audio Output level for the AES Digital Output which appears on the rear panel
Right Trim
Allows a
Samp. Rate (Sample Rate)
Configures the Output Sample Rate. Options are as follows:
[48k]
Slaves the output sample rate to the Omnia’s internal 48kHz sample clock. To use output sample rates other than 48 kHz, Input or External sync must be used.
[Input]
Slaves the output sample rate to the sample rate present on the Omnia’s AES
digital input. Synchronization is possible over a range of sample rates from 32kHz to 96kHz.
[Ext] (External)
OmniaONE Multicast - Use and Operation Manual – Version 0.90
43