Mtr Select (Meter Select)

Selects whether the Input levels or Output levels are displayed on the front panel L & R LED bargraph meters. Please note that in the initial release software the meters when set to monitor Output levels will only monitor the analog outputs.

Input

There are nine controls under the heading “Input” and each will be explained in the order in which they appear in the menu:

<-Exit

Click on this option to return to the Input/Output submenu.

Input Src (Input Source)

Allows the selection of Analog or AES/EBU (digital) as the primary input source to the

OmniaONE.

Fover Time (Failover Time)

Failover Time is a feature that when set to a value other than zero (disabled) allows the OmniaONE to automatically select another input source if the currently selected one fails. Failover Time is the amount of time that will elapse after the failure of audio before the unit makes the decision to switch to another input. For instance, if Failover Time is set for seven seconds and the primary audio source fails, seven seconds later the unit will switch to the secondary audio input. If, at any time, audio is restored on the primary input (for 1 second, continuously), the unit will switch back to the primary audio input. It will remain with the primary input unless another failure is detected.

Fover Src (Failover Source)

Failover Source selects which audio input: Analog or AES/EBU digital will serve as the secondary audio input. Note that the audio input that is selected under Input Source (above) will always be the Primary audio input. A source selected under Failover Source will always be the secondary source.

Anlg Level (Analog Level)

Adjusts the master audio input level for the analog inputs which are derived from the rear panel XLR female input connectors. (See Proper Setting of Input Levels on Page 26)

Right Trim

Allows a +/-3dB adjustment of the right analog audio channel gain to correct minor left/right balance problems in the input audio. The left channel analog input gain is not affected by this control and is set using the master Analog Level control previously described.

AES Level (AES/EBU Level)

Adjusts the master audio input level for the AES Digital input which is derived from the rear panel RJ-45 StudioHUBconnector. (See Proper Setting of Input Levels on Page 26)

Right Trim

OmniaONE Multicast - Use and Operation Manual – Version 0.90

41

Image 41
Contents Omnia ONE Multicast Installation and Operation Manual Version 0.9i / MarchAudio Processor with Omnia 2101 Superior Avenue Cleveland, Ohio 44114 USAOmniaONE Multicast - Use and Operation Manual - Version January Welcome to Omnia.ONEOmniaONE Multicast - Use and Operation Manual - Version Headphone Jack OmniaONE Quick-Start SetupHeadphone Level Control Jog WheelTable Of Contents Administrative PresetChapter-4 Main Menu Selections ProcessingAppendix A Performance Specifications Overview Sensus→ Technology Audio Processingx3Codec Provisioning MulticastOmniaONE Multicast and HD→ Radio Important Note So… what’s so smart about Sensus→?Sincerely The Omnia Development TeamS A F E T Y I N S T R U C T I O N S The Lightning Flash With HAZARD / WARNING LABELSThe Exclamation Point with the EU RoHS Directive Manual Update Notification Pre-Installation Tasks Chapter-1 InstallationAC Power Environment About This ManualOmniaONE utilizes an un-switched EMI-filtered IEC power-entry module Installation & ConnectionsAnalog Audio Inputs and Outputs A Note About Relative PhaseRear Panel Connections Ethernet 10BaseT/100BaseT Remote and Livewire I/O Ethernet ConnectionRS-232 Modem Port RS-232 Modem Connection DB-9FGeneral Purpose Interface GPI DB-9M Powering UpDB-9M GPI “Interface” Connector The OmniaONE User Interface Chapter-2 Getting To Know Your OmniaONEHeadphone Level Control Level Meters & Processing BargraphsAudio I/O Level Display Audio I/O Level DisplayProcessing Meter Display Using the Jog Wheel The OmniaONE Main Menu offers five selections Main MenuPreset Processing Input/Output Administrative Proper Setting of Input Levels Quality Versus Density Chapter-3 Getting The Sound You WantA Word About Density, Clarity, and Intelligibility Increasing Density/Loudness Equalization EQ Changes Adding More Detail-When Loudness Isn’t The Last Word2. Increase the Drive to Low Frequency Limiter Thunder Bass3. Increase the Release setting in the Low Frequency Limiter Processing PresetChapter-4 Main Menu Selections Delete Preset Save PresetAdjust Processing Rename PresetExit Pre-processingEnhancers Low Band AGC Xover CrossoverLow Drive Mid DrivePres Band AGC Presence Band AGC Mid Band AGCHigh Band AGC Low Band LimiterPresence Band Limiter Mid Band LimiterHigh Band Limiter MixerHi Band Sensus→Sen Freq Sensus→ Frequency Sen Level Sensus→ LevelIMPORTANT NOTE Final LimitInput/Output Input Mtr Select Meter SelectInvert Output Bypass Save IO ConfigLoad IO Config AdministrativeDelete IO Config Rename IO ConfigReboot Network ConfigurationAbout ContrastLock Front Panel OmniaONE Multicast - Use and Operation Manual - Version OmniaONE Multicast Appendix A Performance SpecificationsGPI Interface Configuration Four fully optoisolated inputs Shipping Weight 10 lbs. / 4.54 kg OmniaONE Multicast - Use and Operation Manual - Version Diagnostic and Error Messages Appendix B Troubleshooting/Service/WarrantyElectrical and mechanical safety note 3. Unit will not boot Narrowing down problemsVia the World Wide Web Obtaining ServiceVia E-Mail Via Phone & Mail USA and non-European CountriesWarranty OmniaONE Multicast - Use and Operation Manual - Version Remote Control Appendix C Remote Control & Software Update ProcedureSoftware Update Procedure Trigger Scripts7. Click the Status Page link Return to Configuration. Reboot Processor