Sears 831.105021 Symptom the Water Level Drops, Some water loss due to evaporation is normal

Page 19

8.SYMPTOM: THE WATER PULSATES OR THERE IS MINIMUM WATER FLOW

a.Adjust the water level. This usually occurs only when the water level is low. Add water until the thera-jets are covered (see step 4 on page 9).

9.SYMPTOM: THE WATER LEVEL DROPS

a.Some water loss due to evaporation is normal.

If rapid water loss occurs, or if you notice wet- ness on the floor around the hydrotherapy spa, then the spa shell may have a leak. Contact your local spa and pool service provider for repairs.

b. A clamp or seal inside the pump compartment may be loose. Check inside the pump compart- ment for excess water, and watch the pump unit while it is operating to see if water drips

from any of the plumbing. If you can identify the location of the leak inside the spa jet unit, tight- en the clamp or replace the damaged seal.

10.SYMPTOM: THE SPA CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF

a. To turn the spa jets on, press the Pump button once. To turn the spa jets off, press the control twice. After you press it once, the spa jets will shut off for about 30 seconds, and restart. Press the control again. The spa jets will remain off for three hours, at which time they will begin running the filter cycle. At any time after the spa jets has been shut off, the pump will begin cycling the water if the temperature falls below the minimum setting.

11.SYMPTOM: NO AIR FLOWS THROUGH THE

MULTI-DIRECTIONAL HYDRO-JETS WHEN

THE AIR CONTROL IS TURNED COUNTER-

CLOCKWISE

a. The three multi-directional hydro-jets can be closed and opened by pushing and pulling the nozzles. If no air flows through the jets when the air control is turned counterclockwise, sim- ply pull the nozzles slightly.

19

Image 19
Contents 800 Model No Serial NoTable of Contents Important Do not allow the hydrotherapy Important Safety InstructionsSPA Use the hydrotherapy spa only as described This manualMinimum No AWG 13.3 mm Up the hydrotherapy spa within five feetMust always be open Uct Privacy of your own home Fully before using the RenewConsole Spa Shell Light Spa Cover Access Filter Before YOU BeginIf you set up the hydrotherapy spa outside If you set up the hydrotherapy spa insideChoosing a Location for the Hydrotherapy SPA Assembly Requires the Following SET-UP and AssemblySpa Do not overfillSpa to be used before the warning sign is posted Plugging in the Hydrotherapy SPA Testing and Treating the WaterStarting the Hydrotherapy SPA Ozone jet SPA Shell Diagram SPA OperationSix uni-directional thera-jets Suction ventOr heating the water as needed Console DiagramCord must be unplugged Light Button Securing the SPA Cover Posting the Warning SignAttaching the RED and Blue Light Covers Maintenance Maintaining the Proper PH Balance Access Panel ScrewsNever mix different chemicals Always store chemicals in a cool, dry placeHydrotherapy spa should always be covered Draining the Hydrotherapy SPAOpening and Closing the CUT-OFF Valves Winter USE and Care Converting the SPA to a 240 Volt Power SourceChecking and Cleaning the Filter Adjusting the Filter DiverterTrouble -SHOOTING Symptom the SPA will not OperateSymptom the Pump Hums Symptom the Water does not HeatSome water loss due to evaporation is normal Symptom the Water Level DropsKey No. Qty Description Part LIST-Model NoExploded DRAWING-Model No Page Page Part No R1200A Ordering Replacement PartsLimited Five Year Massage SPA Warranty Icon Health & FITNESS, INC., 1500 S W., LOGAN, UT