Stow manual Stow G-4.5R Rules for Safe Operation, Power Cord Safety

Page 11

STOW G-4.5R — RULES FOR SAFE OPERATION

ALWAYS be sure the operator is familiar with proper safety precautions and operation techniques before using generator.

NEVER leave the generator unattended, turn off engine when unattended.

Unauthorized equipment modifications will void all warranties.

ALWAYS ensure generator is on level ground before use.

DO NOT place hands or fingers inside generator engine compartment when engine is running.

NEVER run engine without air cleaner. Severe engine damage may occur.

NEVER change or adjust the engine speed which has been set at the factory prior to shipping.

Power Cord Safety

NEVER let power cables or cords lay in water.

NEVER stand in water while AC power from the generator is being transfer to a load.

NEVER use a defective or frayed power cable. Check the cable for cuts in the insulation.

NEVER use a extension cord that is frayed or damaged where the insulation has been cut.

ALWAYS make certain that proper power or extension cord has been selected for the job See Table 4.

Grounding Safety

ALWAYS make sure that electrical circuits are properly grounded per the National Electrical Code (NEC) and local codes before operating generator. Severe injury or death! by electrocution can result from operating an ungrounded generator.

ALWAYS make sure generator is properly grounded to a suitable earth ground (GROUND ROD). See installation section in this manual.

NEVER use gas piping as an electrical ground.

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

HighTemperatures – Always stop engine and allow the engine to cool before adding fuel, oil or performing service and maintenance functions. Contact with hot! components can cause serious burns.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and replace any broken parts immediately.

ALWAYS replace any worn or damaged warning decals.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and un-authorized personnel.

The electrical voltage required to operate the generator can cause severe injury or even death through physical contact with live circuits. Turn all circuit breakers OFF before performing maintenance on the generator.

Dispose of hazardous waste properly.Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source.

Removing the engine oil drain plug while the engine is hot will result in hot oil to gush out of the oil drain plug, therefore causing severescaldingtoanypersonsinthegeneral area of the generator.

STOW G-4.5R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #3 (03/13/06) — PAGE 11

Image 11
Contents Model G-4.5R Page Heres HOW to GET Help Table of Contents When ordering parts Please supply the following information Parts Ordering ProceduresDimensions Stow G-4.5R DimensionsEffects of Altitude and Heat SpecificationsRespiratory Hazards Stow G-4.5R Safety Message Alert SymbolsBurn Hazards Rotating Parts Hazards Equipment DamageRead this manual Stow G-4.5R Rules for Safe OperationStow G-4.5R Rules for Safe Operation Power Cord SafetyEmergencies DeathPage Machine Safety Decals Operation and Safety Decals S/N 5498030 and belowOperation and Safety Decals S/N 5498031 and Above Engine Stow G-4.5R FamilarizationControl Panel Excitation SystemSmall Motors Single Phase LoadStow G-4.5R Load Application Incandescent LoadsGenerator Controls and Components Stow G-4.5R Controls and IndicatorsStow G-4.5R Controls and Indicators Stow G-4.5R Controls and Indicators With S/N 5498031 and above Generator Refueling Stow G-4.5R Generator RefuelingMounting Stow G-4.5R InstallationOutdoor Installation Indoor InstallationConnecting the Ground Stow G-4.5R InstallationMain Circuit Breaker General Inspection Prior to Operation Ground Power ToolsExtension Cable Fuel Check Stow G-4.5R PRE-INSPECTION EngineBefore Starting Engine Oil CheckBefore Starting the Engine Stow G-4.5R Initial START-UP EngineNoises that would associate with lose components Stow G-4.5R Initial START-UP ENGINE/OPERATION120 VAC Receptacles Main Circuit Breaker on Stopping The EngineGenerator Storage Stow G-4.5R Preparation for Long -TERM StoragePage Engine Maintenance Schedule Stow G-4.5R Maintenance EngineMaintenance Stow G-4.5R Maintenance EngineCleaning the Fuel Strainer Generator/Engine Wiring Diagram S/N 5498030 and Below Stow G-4.5R Wiring Diagram S/N 5498030 and belowStow G-4.5R Wiring Diagram S/N 5498031 and Above Stow G-4.5R -TROUBLESHOOTING Engine White Stow G-4.5R -TROUBLESHOOTING EngineGenerator Troubleshooting Stow G-4.5R -TROUBLESHOOTING GeneratorPage Items Found In the Items Number Column How to read the marks and remarks used in this parts bookTo 3 Units Stow G-4.5R Suggested Spare PartsNameplate and Decals S/N 5498030 and below Stow G-4.5R Name Plate and Decals S/N 5498030 and belowStow G-4.5R Name Plate and Decals S/N 5498030 and below Nameplate and Decals S/N 5498031 and Above Stow G-4.5R Name Plate and Decals S/N 5498030 and AboveDecal Operating Instructions Decal StowDecalwarning Read Manual Generator Assy Stow G-4.5R Generator AssySpring Washer Field Coil AssySET BOLT, Rotor SET WASHER, BearingControl BOX ASSY. S/N 549830 and below Stow G-4.5R Control BOX ASSY. S/N 549830 and belowStow G-4.5R Control BOX ASSY. S/N 549830 and below Control BOX ASSY. S/N 549831 and Above Stow G-4.5R Control BOX ASSY. S/N 549831 and AboveVR1H102MHA Stow G-4.5R Control BOX ASSY. S/N 549831 and AboveHEX NUT Pipe Frame ASSY. S/N 549830 and below Stow G-4.5R Pipe Frame ASSY. S/N 549830 and belowRubber Suspension Pipe FrameSUPPORT, Pipe Frame Engine BasePipe Frame ASSY. S/N 549830 and Above Stow G-4.5R Pipe Frame ASSY. S/N 549831 and AboveWASHER, Flat HangerPlastic Washer HEX Head BoltCrankcase Assy Robin EX270D20110- Crankcase AssyBall Bearing Valve GuideStem Seal OIL SealCrankshaft and Piston Assy Robin EX270D20110 Crankshaft and Piston AssyWoodruff KEY Connecting ROD BoltCrankshaft CP Flange NUTGovernor Assy Robin EX270D20110 Governor AssyGovernor Shaft SPRING, AdjustGovernor Operation Assy Governor LeverIntake and Exhaust Assy Robin EX270D20110 Intake and Exhaust AssyRelease Lever Adjust SCREW, M5X0.5X23LPIN, CAMSHAFT, 9DX78.5L Spring PIN, 4DX7.5DX11LAIR Cleaner Assy Robin EX270D20110 AIR Cleaner AssyElement Assy Body CPCOVER, LOW Profile Cooling Starting Assy Robin EX270D20110 Cooling Starting AssyBaffle 2, Head Blower Housing CP, YellowLABEL, Trademark 64D Baffle 1, Case CPFuel Lubricant Assy Robin EX270D20110 Carburetor AssyJET Slow Screw AdjustingValve Throttle Valve ChokeFlywheel Assy Robin EX270D20110 Flywheel AssyIgnition Coil CP Wire 2 CP, W/OIL SensorSwitch Assy Flywheel CPElectric Device Assy Robin EX270D20110 Electric Device AssyClamp CP OIL Sensor CPFLOAT, C/U CP3 Tapping BoltTerms and Conditions of Sale Stow Construction Equipment Page Heres HOW to GET Help

G-4.5R specifications

The Stow G-4.5R is an exceptional piece of rugged engineering designed for professionals who require efficiency and reliability in demanding environments. This cutting-edge equipment stands out for its unique combination of robust features and innovative technologies.

At the heart of the G-4.5R is its powerful engine, designed to facilitate high-performance operations. The machine is equipped with a fuel-efficient powertrain that not only maximizes output but also minimizes consumption. This feature is crucial for users who need to operate over extended periods without frequent refueling, making the G-4.5R highly suitable for long-term projects.

The G-4.5R boasts an advanced hydraulic system that enhances its lifting capabilities. With optimized hydraulic mechanics, the machine can handle heavier loads with improved precision and speed. This ensures that users can perform tasks more efficiently, reducing downtime and increasing productivity. Furthermore, the hydraulic system is complemented by a robust frame, designed to withstand rigorous field conditions while providing stability during operation.

Another notable aspect of the Stow G-4.5R is its user-centric design. The operational interface is intuitively laid out, allowing users to easily navigate controls and features without extensive training. The ergonomic design of the operating cabin further enhances comfort, reducing fatigue during long working hours. Noise reduction technologies have also been integrated into the design, making the working environment more pleasant.

In terms of technology, the G-4.5R features real-time monitoring systems that provide crucial operational data. These systems allow users to track fuel levels, hydraulic pressures, and performance metrics at a glance. Such capabilities not only promote efficient resource management but also facilitate preventive maintenance, helping to prolong the machine’s lifespan.

Safety is paramount in the design of the G-4.5R, with multiple safety mechanisms in place. These include automatic shutdown features in case of system overloads, reinforced caging to protect operators, and enhanced visibility systems that ensure a clear line of sight during operation.

In summary, the Stow G-4.5R is a versatile, powerful, and user-friendly machine specifically designed for challenging work environments. With its combination of advanced technologies, ergonomic design, and safety features, the G-4.5R stands out as a top choice for professionals aiming for efficiency and reliability in their operations.