![APPLYING POWER](/images/new-backgrounds/88507/8850747x1.webp)
OPERATION
APPLYING POWER
1.If using a portable generator, plug the AC power cable to the 120 VAC receptacle on the generator used. See Figure 27.
120VAC
RECEPTACLE
| 20A | TYPICAL |
|
| |
POWER |
| GENERATOR |
| FRONT PANEL | |
CABLE |
| |
|
| |
| 120V |
|
Figure 27. Connecting to Generator
2.Start the generator as indicated in the generator manual.
3.If using power source other than a portable generator, plug the AC power cord to a 120 VAC, receptacle. See Figure 28.
turn off.
SHUTTING DOWN LAMP ONLY
1. Unzip the bottom of the balloon. See Figure 29.
BALLOON
Figure 29. Unzipping Balloon
2.Push the button above the LED with a blunt object for three seconds as shown in Figure 20. LED will turn red and the lamp will turn off. The balloon will remain deployed.
PUSH WITH
BLUNT OBJECT
POWER CABLE
RECEPTACLE
EXTERNAL
(120 VAC)
POWER SOURCE
Figure 28. Connecting to 120 VAC Receptacle
4.The balloon will start to infl ate as soon as power is applied and the lamp will turn on.
NOTICE
If the power cable is accidentally unplugged from the power source, wait three to fi ve minutes before reconnecting the power. This will allow time for the fan to reset and ensure balloon will infl ate properly when power is reconnected.
SHUTDOWN
1.Turn off the power switch of the generator.
2.Disconnect the AC power cable from the generator. The balloon should start to defl ate and the lamp will
LED
Figure 30. Turning Off Lamp Only
NOTICE
To turn lamp back on, unplug the power cable from the power source. Wait three to fi ve minutes before reconnecting the power. Reconnect the power cable and the lamp should turn on and the balloon will infl ate.
PAGE 24 — GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09)