installation
Connecting the Ground
The nut and ground terminal on the generators should always be used to connect the generators to a suitable ground. The ground cable should be #8 size wire minimum.
At the generator, connect the terminal of the ground cable between the lock washer and the nut (Figure 2) and tighten the nut fully. Connect the other end of the ground cable to a suitable earth ground (ground rod).
120V | |
| 15A |
POWERED by
Honda Engines
211052
GR PRISE DE
TERRE
V 120
AC VOLTMETER VOLTOMETRE CA
OFF
NEUTRAL BONDED TO FRAME
NEUTRE MIS A LA MASSE A LA CARCASSE DU MOTEUR
AC CIRCUIT BREAKER
INTERRUPTEUR DE
COURANT PRINCIPAL
A21210011
|
| GROUND ROD | |
| GROUND | FOR EARTH | |
| GROUND | ||
GENERATOR | CABLE | ||
| |||
GROUND LUG | #8 MINIMUM |
|
CONNECT TO
BUILDING
GROUND
IF REQUIRED
8 FT. MINIMUM
REFERENCE
NEC
Figure 2. Generator Grounding