components (generator)
1 2
120V | |
| 15A |
POWERED by
Honda Engines
211052
GR PRISE DE
TERRE
7
6 5 4
V 120
AC VOLTMETER VOLTOMETRE CA
OFF
NEUTRAL BONDED TO FRAME
NEUTRE MIS A LA MASSE A
LA CARCASSE DU MOTEUR
3
AC CIRCUIT BREAKER
INTERRUPTEUR DE
COURANT PRINCIPAL
A21210011
Figure 3. Generator Components
1.GFCI Duplex Receptacle – NEMA
2.
To prevent damage to the generator or power tools due to low output voltage, turn the generator OFF and consult your authorized Multiquip service dealer.
3.Main Breaker –
4.Engine Oil Filler Cap – Remove cap/dipstick when the adding of engine oil is required. See Table 4 for recommended type engine oil.
5.Chassis Ground – This ground connection point should be connected to a good earth ground (ground rod).
6.Engine ON/OFF Switch – Use this switch to start and stop the engine. Place switch in ON position to start engine, to stop engine place switch in OFF position.
7.GFCI Ground – GFCI ground connection point.
gac2.2H 60 hz GENERATOR • operation and parts manual — rev. #1 (03/31/10) — page 17