Multiquip DCA45USI2 manual Lug Nut Torque Requirements

Page 43

TRAILER MAINTENANCE

Lug Nut Torque Requirements

It is extremely important to apply and maintain proper wheel mounting torque on the trailer. Be sure to use only the fasteners matched to the cone angle of the wheel. Proper procedure for attachment of the wheels is as follows:

1.Start all wheel lug nuts by hand.

2.Torque all lug nuts in sequence (see Figure 61). DO NOT torque the wheel lug nuts all the way down. Tighten each lug nut in 3 separate passes as defi ned by Table 18.

3.After fi rst road use, retorque all lug nuts in sequence. Check all wheel lug nuts periodically.

Table 18. Tire Torque Requirements

Wheel Size

First Pass

Second Pass

Third Pass

FT-LBS

FT-LBS

FT-LBS

 

 

 

 

 

12"

20-25

35-40

50-65

 

 

 

 

13"

20-25

35-40

50-65

 

 

 

 

14"

20-25

50-60

90-120

 

 

 

 

15"

20-25

50-60

90-120

 

 

 

 

16"

20-25

50-60

90-120

 

 

 

 

Figure 61. Wheel Lug Nuts

Tightening Sequence

NOTICE

NEVER use an pneumatic air gun to tighten wheel lug nuts.

DCA45USI2 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #0 (01/12/11) — PAGE 43

Image 43
Contents This Manual Must Accompany the Equipment AT ALL Times Model DCA45USI2Proposition 65 Warning Administrator Reporting Safety DefectsNhtsa DCA45USI2 Generator Table of ContentsOrdering parts has never been easier Parts Ordering ProceduresSafety Messages Safety InformationGenerator Safety General Safety Always know the location of the nearest Before servicing equipment Engine SafetyFrom fuel vapors or if fuel is spilled on a hot engine Fuel SafetyTowing Safety  Never use fuel as a cleaning agentDevice. All installations should be Electrical SafetyGrounding Safety Power Cord/Cable SafetyEnvironmental Safety Battery SafetyDCA-45USI2 SpecificationsIsuzu BU-4JJ1T Tier Dimensions DimensionsTypical Generator Grounding Application InstallationGenerator Grounding Outdoor InstallationIndoor Installation MountingGeneral Information Major Components Muffl er AssemblyOFF Generator Control PanelPage OFF Engine Operating PanelEngine Operating Panel Output Terminal Familiarization Output Terminal Panel FamiliarizationTerminal legs O and Ground are considered bonded grounds VAC Gfci Receptacles Removing the Plastic Face Plate Hard Wire Hookup PanelOver Current Relay Connecting LoadsThree Phase Load Single Phase LoadLoad Application Generator Output Voltages Generator OutputsAC Ammeter Gauge Reading HOW to Read the AC Ammeter and AC Voltage GaugesGenerator OUTPUTS/GAUGE Reading AC Voltmeter Gauge Reading3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 3Ø-240/139 Uvwo Terminal Output Voltages1Ø-240/120V Uvwo Terminal Output Voltages 3Ø-480/277V Uvwo Terminal Output VoltagesFuel Check INSPECTION/SETUPCircuit Breakers Lubrication OILOnly use #2 diesel fuel when refueling Refueling ProcedureOperation Freezing Weather Cleaning the RadiatorAIR Cleaner FAN Belt Tension Coolant ANTIFREEZE/SUMMER COOLANT/ WaterAlternator BatteryBattery Cable Installation WiringStarting Manual Generator START-UP ProcedureBefore Starting StartingEngine Speed Switch High Place the Mpec Control Switch in the OFF/RESET position Generator SHUT-DOWN ProceduresNormal Shutdown Procedure Emergency Shutdown ProcedureGeneral Inspection AIR Cleaner MaintenanceAir Cleaner with Dust Indicator Fuel Tank Inspection Fuel AdditionAIR Removal Flushing OUT Radiator and Replacing Coolant Radiator CleaningCheck OIL Level Replacing Oil FilterTrailer Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Actuator Brake AdjustmentBrakes Hydraulic Surge BrakesTire Wear/Inflation TIRES/WHEELS/LUG NutsSuspension Never use an pneumatic air gun to tighten wheel lug nuts Lug Nut Torque RequirementsTrailer/Towing Vehicle Wiring Diagram Trailer Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramEngine Controller Controller Wiring DiagramTroubleshooting Generator Method of Operation Troubleshooting Diagnostic LampExplanation of Code in Remarks Column Sample Parts ListTo 3 units Suggested Spare PartsGenerator Assy ZNR Balancing WeightRotor Assy Field Assy RectifierControl BOX Assy Edging Push Button SwitchDiagnostic Switch Control BOXControl BOX Assy BRACKET, Sensor Selector SwitchSwitch Bracket Switch CoverControl BOX Assy SWITCH, Engine Speed SwitchAlarm Lamp SWITCH, Panel LightEngine and Radiator Assy BRACKET, AIR Cleaner AIR CleanerELEMENT, AIR Cleaner INDICATOR, AIR CleanerEngine and Radiator Assy Valve ConnectorElbow LocknutOutput Terminal Assy Terminal Cover Terminal PanelOutput Terminal Bolt TIE ScrewBattery Assy Battery Bolt SET BatteryBattery Sheet Battery BandMuffler Assy Seal Clamp MufflerHEX Head Bolt Exhaust PipeFuel Tank Assy Gasket Fuel TankFuel Tank CAP Fuel Sender UnitEnclosure Assy Front Frame BaseAcoustic Sheet Environmental TankEnclosure Assy Roof Panel Rear DoorWindow Plate Door Handle ASS YRubber Seals Assy Seal Rubber Nameplate and Decals Assy M1550001504 M1550000204M1550000703 M1550000804Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

DCA45USI2 specifications

The Multiquip DCA45USI2 is a robust and versatile generator that caters to a wide array of power needs across various applications. Designed for both commercial and industrial use, this generator stands out due to its powerful output, durability, and advanced technology.

The DCA45USI2 offers a maximum output of 45 kVA, making it suitable for both demanding construction sites and as a backup power source for critical equipment in emergencies. It operates with a reliable Yanmar diesel engine, known for its fuel efficiency and longevity, ensuring that users can count on consistent performance over extended periods. The unit is built to provide high-quality electrical output, ensuring that sensitive equipment is protected from surges and fluctuations.

One of the standout features of the DCA45USI2 is its sound attenuation technology. Enclosed within a sturdy yet compact frame, this generator is designed to minimize noise levels, making it an ideal choice for urban environments or noise-sensitive applications. The insulation materials used are specifically chosen to absorb sound waves while still allowing for efficient ventilation.

In terms of ease of use, the DCA45USI2 is equipped with a user-friendly control panel that provides comprehensive monitoring capabilities. This includes advanced protective features, such as low oil pressure shutdown, high-temperature shutdown, and overload protection, ensuring that the generator operates safely at all times. The digital display offers real-time information on vital operating parameters, enabling operators to swiftly respond to any issues that may arise.

Another key characteristic of the DCA45USI2 is its portability. Weighing in at a manageable level for its size and capacity, it features heavy-duty wheels and a lifting eye which allow for easy transportation across job sites. This adaptability is crucial for rental companies and contractors who require a reliable source of power on-the-go.

Overall, the Multiquip DCA45USI2 embodies a blend of power, efficiency, and convenience. Its advanced engineering and thoughtful design cater to the needs of various industries, making it a preferred choice among professionals who demand reliability and performance from their equipment. Whether for construction, emergency response, or temporary power solutions, the DCA45USI2 proves to be a formidable ally in getting the job done efficiently and effectively.