Multiquip DCA45USI2 manual Fuel Safety, Towing Safety,  Never use fuel as a cleaning agent

Page 9

SAFETY INFORMATION

FUEL SAFETY

DANGER

DO NOT start the engine near spilled fuel or combustible fl uids. Diesel fuel is extremely fl ammable and its vapors can cause an explosion if ignited.

ALWAYS refuel in a well-ventilated area, away from sparks and open fl ames.

ALWAYS use extreme caution when working with flammable liquids.

DO NOT fi ll the fuel tank while the engine is running or hot.

DO NOT overfi ll tank, since spilled fuel could ignite if it comes into contact with hot engine parts or sparks from the ignition system.

Store fuel in appropriate containers, in well-ventilated areas and away from sparks and fl ames.

NEVER use fuel as a cleaning agent.

DO NOT smoke around or near the equipment. Fire or explosion could result

from fuel vapors or if fuel is spilled on a hot engine.

TOWING SAFETY

CAUTION

Check with your local county or state safety

towing regulations, in addition to meeting

Department of Transportation (DOT) SafetyTowing Regulations, before towing your generator.

Refer to MQ Power trailer manual for additional safety information.

In order to reduce the possibility of an accident while transporting the generator on public roads, ALWAYS make sure the trailer that supports the generator and the towing vehicle are mechanically sound and in good operating condition.

ALWAYS shutdown engine before transporting

Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer “gross vehicle weight rating.”

ALWAYS inspect the hitch and coupling for wear. NEVER tow a trailer with defective hitches, couplings, chains, etc.

Check the tire air pressure on both towing vehicle and trailer. Trailer tires should be inflated to 50 psi cold. Also check the tire tread wear on both vehicles.

ALWAYS make sure the trailer is equipped with a safety chain.

ALWAYS properly attach trailer’s safety chains to towing vehicle.

ALWAYS make sure the vehicle and trailer directional, backup, brake and trailer lights are connected and working properly.

DOT Requirements include the following:

Connect and test electric brake operation.

Secure portable power cables in cable tray with tie wraps.

The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

Avoid sudden stops and starts.This can cause skidding, or jack-knifi ng. Smooth, gradual starts and stops will improve towing.

Avoid sharp turns to prevent rolling.

Trailer should be adjusted to a level position at all times when towing.

Raise and lock trailer wheel stand in up position when towing.

Place chock blocks underneath wheel to prevent rolling while parked.

Place support blocks underneath the trailer’s bumper to prevent tipping while parked.

Use the trailer’s swivel jack to adjust the trailer height to a level position while parked.

DCA45USI2 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #0 (01/12/11) — PAGE 9

Image 9
Contents This Manual Must Accompany the Equipment AT ALL Times Model DCA45USI2Proposition 65 Warning Reporting Safety Defects AdministratorNhtsa DCA45USI2 Generator Table of ContentsOrdering parts has never been easier Parts Ordering ProceduresSafety Messages Safety InformationGeneral Safety Generator Safety Always know the location of the nearest Before servicing equipment Engine SafetyTowing Safety Fuel Safety Never use fuel as a cleaning agent From fuel vapors or if fuel is spilled on a hot engineGrounding Safety Electrical SafetyPower Cord/Cable Safety Device. All installations should beEnvironmental Safety Battery SafetySpecifications DCA-45USI2Isuzu BU-4JJ1T Tier Dimensions DimensionsTypical Generator Grounding Application InstallationIndoor Installation Outdoor InstallationMounting Generator GroundingGeneral Information Major Components Muffl er AssemblyOFF Generator Control PanelPage OFF Engine Operating PanelEngine Operating Panel Output Terminal Panel Familiarization Output Terminal FamiliarizationTerminal legs O and Ground are considered bonded grounds VAC Gfci Receptacles Removing the Plastic Face Plate Hard Wire Hookup PanelOver Current Relay Connecting LoadsSingle Phase Load Three Phase LoadLoad Application Generator Output Voltages Generator OutputsGenerator OUTPUTS/GAUGE Reading HOW to Read the AC Ammeter and AC Voltage GaugesAC Voltmeter Gauge Reading AC Ammeter Gauge ReadingUvwo Terminal Output Voltages Output Terminal Panel Connections3Ø-240/139 Uvwo Terminal Output Voltages 3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages1Ø-240/120V Uvwo Terminal Output Voltages 3Ø-480/277V Uvwo Terminal Output VoltagesCircuit Breakers INSPECTION/SETUPLubrication OIL Fuel CheckOnly use #2 diesel fuel when refueling Refueling ProcedureAIR Cleaner FAN Belt Tension Cleaning the RadiatorCoolant ANTIFREEZE/SUMMER COOLANT/ Water Operation Freezing WeatherBattery Cable Installation BatteryWiring AlternatorBefore Starting Generator START-UP ProcedureStarting Starting ManualEngine Speed Switch High Normal Shutdown Procedure Generator SHUT-DOWN ProceduresEmergency Shutdown Procedure Place the Mpec Control Switch in the OFF/RESET positionMaintenance General Inspection AIR CleanerAir Cleaner with Dust Indicator Fuel Addition Fuel Tank InspectionAIR Removal Check OIL Level Radiator CleaningReplacing Oil Filter Flushing OUT Radiator and Replacing CoolantTrailer Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Brakes Brake AdjustmentHydraulic Surge Brakes ActuatorTIRES/WHEELS/LUG Nuts Tire Wear/InflationSuspension Never use an pneumatic air gun to tighten wheel lug nuts Lug Nut Torque RequirementsTrailer/Towing Vehicle Wiring Diagram Trailer Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramEngine Controller Controller Wiring DiagramTroubleshooting Generator Method of Operation Troubleshooting Diagnostic LampExplanation of Code in Remarks Column Sample Parts ListTo 3 units Suggested Spare PartsGenerator Assy Rotor Assy Field Assy Balancing WeightRectifier ZNRControl BOX Assy Diagnostic Switch Push Button SwitchControl BOX EdgingControl BOX Assy Switch Bracket Selector SwitchSwitch Cover BRACKET, SensorControl BOX Assy Alarm Lamp SwitchSWITCH, Panel Light SWITCH, Engine SpeedEngine and Radiator Assy ELEMENT, AIR Cleaner AIR CleanerINDICATOR, AIR Cleaner BRACKET, AIR CleanerEngine and Radiator Assy Elbow ConnectorLocknut ValveOutput Terminal Assy Output Terminal Bolt Terminal PanelTIE Screw Terminal CoverBattery Assy Battery Sheet BatteryBattery Band Battery Bolt SETMuffler Assy HEX Head Bolt MufflerExhaust Pipe Seal ClampFuel Tank Assy Fuel Tank CAP Fuel TankFuel Sender Unit GasketEnclosure Assy Acoustic Sheet BaseEnvironmental Tank Front FrameEnclosure Assy Window Plate Rear DoorDoor Handle ASS Y Roof PanelRubber Seals Assy Seal Rubber Nameplate and Decals Assy M1550000703 M1550000204M1550000804 M1550001504Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

DCA45USI2 specifications

The Multiquip DCA45USI2 is a robust and versatile generator that caters to a wide array of power needs across various applications. Designed for both commercial and industrial use, this generator stands out due to its powerful output, durability, and advanced technology.

The DCA45USI2 offers a maximum output of 45 kVA, making it suitable for both demanding construction sites and as a backup power source for critical equipment in emergencies. It operates with a reliable Yanmar diesel engine, known for its fuel efficiency and longevity, ensuring that users can count on consistent performance over extended periods. The unit is built to provide high-quality electrical output, ensuring that sensitive equipment is protected from surges and fluctuations.

One of the standout features of the DCA45USI2 is its sound attenuation technology. Enclosed within a sturdy yet compact frame, this generator is designed to minimize noise levels, making it an ideal choice for urban environments or noise-sensitive applications. The insulation materials used are specifically chosen to absorb sound waves while still allowing for efficient ventilation.

In terms of ease of use, the DCA45USI2 is equipped with a user-friendly control panel that provides comprehensive monitoring capabilities. This includes advanced protective features, such as low oil pressure shutdown, high-temperature shutdown, and overload protection, ensuring that the generator operates safely at all times. The digital display offers real-time information on vital operating parameters, enabling operators to swiftly respond to any issues that may arise.

Another key characteristic of the DCA45USI2 is its portability. Weighing in at a manageable level for its size and capacity, it features heavy-duty wheels and a lifting eye which allow for easy transportation across job sites. This adaptability is crucial for rental companies and contractors who require a reliable source of power on-the-go.

Overall, the Multiquip DCA45USI2 embodies a blend of power, efficiency, and convenience. Its advanced engineering and thoughtful design cater to the needs of various industries, making it a preferred choice among professionals who demand reliability and performance from their equipment. Whether for construction, emergency response, or temporary power solutions, the DCA45USI2 proves to be a formidable ally in getting the job done efficiently and effectively.