Multiquip DCA45USI2 manual Coolant ANTIFREEZE/SUMMER COOLANT/ Water, Operation Freezing Weather

Page 32

INSPECTION/SETUP

COOLANT (ANTIFREEZE/SUMMER COOLANT/ WATER)

ISUZU recommends ISUZU antifreeze/summer coolant for use in their engines, which can be purchased in concentrate (and mixed with 50% demineralized water) or pre-diluted. See the ISUZU Engine Owner’s Manual for further details.

WARNING

If adding coolant/antifreeze mix to the radiator, DO NOT remove the radiator cap until the unit has completely cooled. The possibility of hot! coolant exists which can cause severe burns.

Day-to-day addition of coolant is done from the recovery tank. When adding coolant to the radiator, DO NOT remove the radiator cap until the unit has completely cooled. See Table 12 for engine, radiator, and recovery tank coolant capacities. Make sure the coolant level in the recovery tank is always between the “H” and the “L” markings.

Table 12. Coolant Capacity

Engine and Radiator

 

3.15 gal (12 liters)

Reserve Tank

 

2 quarts (1.9 liters)

Operation in

Freezing

Weather

When operating

in freezing

weather, be certain

the proper amount of antifreeze (Table 13) has been added.

 

 

 

 

 

 

 

 

Table 13. Anti-Freeze Operating Temperatures

 

 

 

 

 

 

 

 

 

Vol %

Freezing Point

Boiling Point

 

 

Anti-

°C

°F

°C

°F

 

 

Freeze

 

 

 

 

 

 

 

 

50

-37

-34

108

226

 

 

 

 

 

 

 

 

NOTICE

When the antifreeze is mixed with water, the antifreeze mixing ratio must be less than 50%.

CLEANING THE RADIATOR

The engine may overheat if the radiator fi ns become overloaded with dust or debris. Periodically clean the radiator fi ns with compressed air. Cleaning inside the machine is dangerous, so clean only with the engine turned off and the negative battery terminal disconnected.

AIR CLEANER

Periodic cleaning/replacement is necessary. Inspect it in accordance with the ISUZU Engine Owner’s Manual.

FAN BELT TENSION

A slack fan belt may contribute to overheating, or to insuffi cient charging of the battery. Inspect the fan belt for damage and wear and adjust it in accordance with the

ISUZU Engine Owner’s Manual.

The fan belt tension is proper if the fan belt bends 10 to 15

mm(Figure 34) when depressed with the thumb as shown below.

Figure 34. Fan Belt Tension

CAUTION

NEVER place hands near the belts or fan while the generator set is running.

PAGE 32 — DCA45USI2 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #0 (01/12/11)

Image 32
Contents Model DCA45USI2 This Manual Must Accompany the Equipment AT ALL TimesProposition 65 Warning Nhtsa Reporting Safety DefectsAdministrator Table of Contents DCA45USI2 GeneratorParts Ordering Procedures Ordering parts has never been easierSafety Information Safety Messages Always know the location of the nearest General SafetyGenerator Safety Engine Safety Before servicing equipmentFuel Safety Towing Safety Never use fuel as a cleaning agent From fuel vapors or if fuel is spilled on a hot engineElectrical Safety Grounding SafetyPower Cord/Cable Safety Device. All installations should beBattery Safety Environmental SafetyIsuzu BU-4JJ1T Tier SpecificationsDCA-45USI2 Dimensions DimensionsInstallation Typical Generator Grounding ApplicationOutdoor Installation Indoor InstallationMounting Generator GroundingGeneral Information Muffl er Assembly Major ComponentsGenerator Control Panel OFFPage Engine Operating Panel OFFEngine Operating Panel Terminal legs O and Ground are considered bonded grounds Output Terminal Panel FamiliarizationOutput Terminal Familiarization Removing the Plastic Face Plate Hard Wire Hookup Panel VAC Gfci ReceptaclesConnecting Loads Over Current RelayLoad Application Single Phase LoadThree Phase Load Generator Outputs Generator Output VoltagesHOW to Read the AC Ammeter and AC Voltage Gauges Generator OUTPUTS/GAUGE ReadingAC Voltmeter Gauge Reading AC Ammeter Gauge ReadingOutput Terminal Panel Connections Uvwo Terminal Output Voltages3Ø-240/139 Uvwo Terminal Output Voltages 3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages3Ø-480/277V Uvwo Terminal Output Voltages 1Ø-240/120V Uvwo Terminal Output VoltagesINSPECTION/SETUP Circuit BreakersLubrication OIL Fuel CheckRefueling Procedure Only use #2 diesel fuel when refuelingCleaning the Radiator AIR Cleaner FAN Belt TensionCoolant ANTIFREEZE/SUMMER COOLANT/ Water Operation Freezing WeatherBattery Battery Cable InstallationWiring AlternatorGenerator START-UP Procedure Before StartingStarting Starting ManualEngine Speed Switch High Generator SHUT-DOWN Procedures Normal Shutdown ProcedureEmergency Shutdown Procedure Place the Mpec Control Switch in the OFF/RESET positionAir Cleaner with Dust Indicator MaintenanceGeneral Inspection AIR Cleaner AIR Removal Fuel AdditionFuel Tank Inspection Radiator Cleaning Check OIL LevelReplacing Oil Filter Flushing OUT Radiator and Replacing CoolantCoupler Type of hitch used on the trailer for towing Trailer MaintenanceTrailer Maintenance Brake Adjustment BrakesHydraulic Surge Brakes ActuatorSuspension TIRES/WHEELS/LUG NutsTire Wear/Inflation Lug Nut Torque Requirements Never use an pneumatic air gun to tighten wheel lug nutsTrailer Wiring Diagram Trailer/Towing Vehicle Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramController Wiring Diagram Engine ControllerTroubleshooting Generator Troubleshooting Diagnostic Lamp Method of OperationSample Parts List Explanation of Code in Remarks ColumnSuggested Spare Parts To 3 unitsGenerator Assy Balancing Weight Rotor Assy Field AssyRectifier ZNRControl BOX Assy Push Button Switch Diagnostic SwitchControl BOX EdgingControl BOX Assy Selector Switch Switch BracketSwitch Cover BRACKET, SensorControl BOX Assy Switch Alarm LampSWITCH, Panel Light SWITCH, Engine SpeedEngine and Radiator Assy AIR Cleaner ELEMENT, AIR CleanerINDICATOR, AIR Cleaner BRACKET, AIR CleanerEngine and Radiator Assy Connector ElbowLocknut ValveOutput Terminal Assy Terminal Panel Output Terminal BoltTIE Screw Terminal CoverBattery Assy Battery Battery SheetBattery Band Battery Bolt SETMuffler Assy Muffler HEX Head BoltExhaust Pipe Seal ClampFuel Tank Assy Fuel Tank Fuel Tank CAPFuel Sender Unit GasketEnclosure Assy Base Acoustic SheetEnvironmental Tank Front FrameEnclosure Assy Rear Door Window PlateDoor Handle ASS Y Roof PanelRubber Seals Assy Seal Rubber Nameplate and Decals Assy M1550000204 M1550000703M1550000804 M1550001504Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help

DCA45USI2 specifications

The Multiquip DCA45USI2 is a robust and versatile generator that caters to a wide array of power needs across various applications. Designed for both commercial and industrial use, this generator stands out due to its powerful output, durability, and advanced technology.

The DCA45USI2 offers a maximum output of 45 kVA, making it suitable for both demanding construction sites and as a backup power source for critical equipment in emergencies. It operates with a reliable Yanmar diesel engine, known for its fuel efficiency and longevity, ensuring that users can count on consistent performance over extended periods. The unit is built to provide high-quality electrical output, ensuring that sensitive equipment is protected from surges and fluctuations.

One of the standout features of the DCA45USI2 is its sound attenuation technology. Enclosed within a sturdy yet compact frame, this generator is designed to minimize noise levels, making it an ideal choice for urban environments or noise-sensitive applications. The insulation materials used are specifically chosen to absorb sound waves while still allowing for efficient ventilation.

In terms of ease of use, the DCA45USI2 is equipped with a user-friendly control panel that provides comprehensive monitoring capabilities. This includes advanced protective features, such as low oil pressure shutdown, high-temperature shutdown, and overload protection, ensuring that the generator operates safely at all times. The digital display offers real-time information on vital operating parameters, enabling operators to swiftly respond to any issues that may arise.

Another key characteristic of the DCA45USI2 is its portability. Weighing in at a manageable level for its size and capacity, it features heavy-duty wheels and a lifting eye which allow for easy transportation across job sites. This adaptability is crucial for rental companies and contractors who require a reliable source of power on-the-go.

Overall, the Multiquip DCA45USI2 embodies a blend of power, efficiency, and convenience. Its advanced engineering and thoughtful design cater to the needs of various industries, making it a preferred choice among professionals who demand reliability and performance from their equipment. Whether for construction, emergency response, or temporary power solutions, the DCA45USI2 proves to be a formidable ally in getting the job done efficiently and effectively.