Multiquip DCA25USIXF Fuel Safety, Towing Safety, „ Never use fuel as a cleaning agent

Page 8

SAFETY INFORMATION

FUEL SAFETY

DANGER

„DO NOT start the engine near spilled fuel or combustible fluids. Diesel fuel is extremely flammable and its vapors can cause an explosion if ignited.

„ALWAYS refuel in a well-ventilated area, away from sparks and open flames.

„ALWAYS use extreme caution when working with flammable liquids.

„DO NOT fill the fuel tank while the engine is running or hot.

„DO NOT overfill tank, since spilled fuel could ignite if it comes into contact with hot engine parts or sparks from the ignition system.

„Store fuel in appropriate containers, in well-ventilated areas and away from sparks and flames.

„NEVER use fuel as a cleaning agent.

„DO NOT smoke around or near the equipment. Fire or explosion could result

from fuel vapors or if fuel is spilled on a hot engine.

TOWING SAFETY

CAUTION

„Check with your local county or state safety

towing regulations, in addition to meeting

Department of Transportation (DOT) SafetyTowing Regulations, before towing your generator.

„Refer to MQ Power trailer manual for additional safety information.

„In order to reduce the possibility of an accident while transporting the generator on public roads, ALWAYS make sure the trailer that supports the generator and the towing vehicle are mechanically sound and in good operating condition.

„ALWAYS shutdown engine before transporting

„Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer “gross vehicle weight rating.”

„ALWAYS inspect the hitch and coupling for wear. NEVER tow a trailer with defective hitches, couplings, chains, etc.

„Check the tire air pressure on both towing vehicle and trailer. Trailer tires should be inflated to 50 psi cold. Also check the tire tread wear on both vehicles.

„ALWAYS make sure the trailer is equipped with a safety chain.

„ALWAYS properly attach trailer’s safety chains to towing vehicle.

„ALWAYS make sure the vehicle and trailer directional, backup, brake and trailer lights are connected and working properly.

„DOT Requirements include the following:

s #ONNECT AND TEST ELECTRIC BRAKE OPERATION

s 3ECURE PORTABLE POWER CABLES IN CABLE TRAY WITH TIE wraps.

„The maximum speed for highway towing is 55 MPH unless posted otherwise.Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

„Avoid sudden stops and starts.This can cause skidding, or jack-knifing. Smooth, gradual starts and stops will improve towing.

„Avoid sharp turns to prevent rolling.

„Trailer should be adjusted to a level position at all times when towing.

„Raise and lock trailer wheel stand in up position when towing.

„Place chock blocks underneath wheel to prevent rolling while parked.

„Place support blocks underneath the trailer’s bumper to prevent tipping while parked.

„Use the trailer’s swivel jack to adjust the trailer height to a level position while parked.

PAGE 8 — DCA25USIXF/DCA25USI2XF — OPERATION AND PARTS MANUAL — REV. #2 (07/26/11)

Image 8
Contents Model DCA25USIXF Model DCA25USI2XF Diesel engine exhaust and some Proposition 65 WarningTable of Contents Parts Ordering Procedures Ordering parts has never been easierSafety Information Safety MessagesGeneral Safety Generator Safety„ Always know the location of the nearest fire extinguisherEngine Safety Before servicing equipmentFuel Safety Towing Safety„ Never use fuel as a cleaning agent 3ECURE Portable Power Cables in Cable Tray with TIE wraps„ Never use gas piping as an electrical ground Electrical SafetyDevice. All installations should be Battery Safety Environmental SafetySpecifications Generator SpecificationsDimensions DimensionsDecals Generator DecalsDecals Installation Typical Generator Grounding ApplicationOutdoor Installation Indoor InstallationMounting Generator Grounding Two auxilliary circuit breakers, 250V @50 amps General InformationFamiliarization Components Major ComponentsGenerator Control Panel Generator Control PanelEngine Operating Panel Fuel Gauge Indicates amount of diesel fuel availableOutput Terminal Panel Output Terminal PanelTerminal legs Oand Ground are considered bonded grounds Output Terminal Familiarization120VAC Gfci Receptacles F.C.I. ReceptacleConnecting Loads Connecting Loads Over Current RelayLoad Application Single Phase LoadThree Phase Load Voltage Selector Switch Gauge READING/TERMINAL Panel ConnectionsGenerator OutputVoltages Maximum AmpsVoltage selector switch Reading VoltageThree-Phase Position Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 3Ø 240/139 Output Terminal Lug VoltagesVoltage Selector Switch 240/120V Single-Phase Position 3Ø 480/277 Output Terminal Lug VoltagesSetup Circuit BreakersLubrication Oil Fuel CheckRefueling Procedure ONLY! use #2 diesel fuel when refuelingCleaning the Radiator Air Cleaner Fan Belt TensionMm when depressed with the thumb as shown below Operation FreezingWeatherBattery Battery Cable InstallationWiring AlternatorStartup Before StartingEngines exhaust contains harmful emissions Direct exhaust away from nearby personnelIgnition Switch Start Position Oil Pressure Gauge Normal Shut-down Procedure Emergency Shut-down ProcedureShutdown Automatic Shut-down SystemMaintenance Cleaning the Fuel Strainer Feed Pump Strainer CleaningAir Removal Check Oil LevelTrailer Maintenance Brake AdjustmentBrakes Check the wheel and drum for free rotationSuspension Tires/Wheels/Lug NutsTireWear/Inflation Lug Nut Torque Requirements Start all wheel lug nuts by handTrailer Wiring Diagram Trailer/Towing Vehicle Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramEngine Wiring Diagram Generator Wiring Diagram Generator Wiring DiagramStarter does not run TroubleshootingEngine does not start Stuck? Generator Troubleshooting Page Xxxxx only Not Used on Sample Parts ListExplanation of Code in Remarks Column Suggested Spare Parts Qty DescriptionGenerator Assy Generator AssyBalancing Weight KIT Field AssyRectifier Surge AbsorberDCA25USIXF Control BOX Assy Control BOX ASSY. Dcausixf onlyDecal Terminal Symbol Control BOXCircuit BREAKER, 3P 60A Machine ScrewDCA25USIXF Control BOX Assy CHANGE-OVER SWITCH, Ammeter Water Temperature GaugeSWITCH, Panel Light Toothed WasherDCA25USI2XF Control BOX Assy Control BOX ASSY. DCAUSI2XF onlySelector Switch Switch BracketSwitch Cover CURRENTTRANSFORMER, 100/5ADCA25USI2XF Control BOX Assy Wire HARNESS, Generator DCA25USIXF Engine and Radiator Assy Engine and Radiator ASSY. Dcausixf onlyAIR Cleaner ELEMENT, AIR CleanerINDICATOR, AIR Cleaner BRACKET, AIR CleanerDCA25USIXF Engine and Radiator Assy UNIT, Water Temperature Drain JointPlug RingDCA25USI2XF Engine and Radiator Assy Engine and Radiator ASSY. DCAUSI2XF onlyENGINE, Isuzu BV-4LE2 DCA25USI2XF Engine and Radiator Assy M1316100603 Output Terminal Assy Output Terminal AssyTerminal Panel Output Terminal BoltTIE Screw Output WindowBattery Assy Battery AssyBattery Battery SheetBattery Band Battery Bolt SETDCA25USIXF Muffler Assy Muffler ASSY. DCA-25USIXF onlyM1332000002 810000 ~8101465M1332000012 M1335000103DCA25USI2XF Muffler Assy Muffler ASSY. DCA-25USI2XF onlyMuffler GasketStay Exhaust PipeFuel Tank Assy Fuel Tank AssyFuel Tank Fuel Tank CAPFuel Sender Unit Tank SupportDCA25USIXF Eclosure Assy Enclosure ASSY. DCA25USIXF onlyBase Acoustic SheetEnvironmental Tank Front FrameDCA25USIXF Eclosure Assy Rear Cover DuctRear Door Window PlateDCA25USIXF Eclosure Assy Fuel Leak Detected Switch Bracket StaySupport LEG BracketDCA25USI2XF Eclosure Assy Enclosure ASSY. DCA25USI2XF onlyCOVER, from Frame Front LouverDCA25USI2XF Eclosure Assy M1443302203 34A M1493305104M1443400103 35A M1493305204DCA25USI2XF Eclosure Assy Manual Holder CLAMP, Manual HolderRubber Seals Assy Rubber Seals Assy0229200790 03145005600229200630 0228901220Nameplate and Decals Assy Name Plate AssyDecal MQ POWER, DCA25USI2 Plate MQ PowerStripe Stripe WhisperwattTerms and Conditions of Sale Parts FreightpolicyPage HERE’S HOW to GET Help

DCA25USI2XF, DCA25USIXF specifications

Multiquip is a renowned name in the construction and industrial equipment sector, known for delivering high-performance generators that cater to various power needs. Two standout models in their lineup are the DCA25USIXF and DCA25USI2XF, both designed for reliability, efficiency, and versatility.

The Multiquip DCA25USIXF is a compact, industrial-grade diesel generator that delivers a powerful 25 kVA, making it ideal for construction sites, outdoor events, and emergency backup applications. This model is powered by a robust Yanmar diesel engine, which ensures high fuel efficiency and low emissions, adhering to stringent environmental standards. The DCA25USIXF features an advanced digital control panel, providing users with an intuitive interface for monitoring performance, voltage output, and operational status. Its sound-attenuated enclosure significantly reduces noise levels, making it suitable for use in noise-sensitive areas.

On the other hand, the DCA25USI2XF model takes power generation a step further by offering dual voltage capabilities, allowing users to switch between 120V and 240V outputs. This flexibility makes it highly versatile, catering to a broader range of tools and equipment. Like the DCA25USIXF, the DCA25USI2XF is also equipped with Yanmar’s reliable diesel engine, which contributes to its durability and long service life. Both models come with a heavy-duty frame to withstand tough conditions, ensuring durability on job sites.

The technology implemented in these generators includes automatic voltage regulation (AVR), which stabilizes voltage output, protecting sensitive equipment from power surges. Additionally, the generators feature a low oil shutdown system, which prevents engine damage by automatically shutting down the generator when oil levels are low. This protective measure not only enhances the longevity of the generator but also contributes to safer operation.

In terms of portability, both models are equipped with rugged wheels and a lifting eye, facilitating easy transportation to various job sites. With their combination of power, efficiency, and advanced features, the Multiquip DCA25USIXF and DCA25USI2XF generators are excellent choices for professionals seeking reliable power solutions in demanding environments. Whether for construction, events, or standby power, these generators deliver exceptional performance tailored to meet diverse needs.