GENERATOR OUTPUTS

Generator Output Voltages

A wide range of voltages are available to supply voltage for many different applications.Voltages are selected by using the voltage selector switch (Figure 13). To obtain some of the voltages as listed in Table 7 (see below) will require a fine adjustment using the voltage regulator (VR) control knob located on the control panel.

Voltage Selector Switch

The voltage selector switch (Figure 13) is located above the output terminal panel’s Hard Wire Hook-up Panel. It has been provided for ease of voltage selection.

Generator Amperage

Table 8 shows the maximum amps the generator can provide. DO NOT exceed the maximum amps as listed..

Table 8. Generator Maximum Amps

Rated Voltage

Maximum Amps

 

 

1Ø 120 Volt

55.5 amps (4 wire)

 

 

1Ø 240 Volt

27.8 amps (4 wire)

 

 

3Ø 240 Volt

60 amps

 

 

3Ø 480 Volt

30 amps

 

 

Figure 13. Voltage Change-Over Board

Voltage Selector Switch Locking Button

To lock the voltage selector switch, press and hold the red button located at the bottom of the switch. While holding the red button down, insert a pad lock into the hole next to the button to retain it in the inward locked position. When the lock is removed, the red button is spring loaded and will return to its normal outward unlocked position .

CAUTION

NEVER change the position of the voltage selector switch while the engine is running. ALWAYS place circuit breaker in the OFF position before selecting voltage.

Table 7. Voltages Available

Three Phase

208V

220V

240V

416V

440V

480V

(Switchable)

 

 

 

 

 

 

 

 

 

 

 

 

 

Single Phase

120V

1127V

139V

240V

254V

277V

(Switchable)

 

 

 

 

 

 

 

 

 

 

 

 

 

GFCI Receptacle Load Capability

The load capability of the GFCI receptacles is directly related to the voltage being supplied at either the output terminals or the 2 twist lock auxiliary receptacles.

Tables 9 and 10 show what amount of current is available at the GFCI receptacles when the output terminals and twist lock receptacles are in use. Be careful that your load does not to exceed the available current capability at the receptacles.

Table 9. 1Ø GFCI Receptacle Load Capacity

KW in Use

Available Load

Twist Lock (C6369)

Current (Amps)

1Ø 240/120V

GFCI Duplex

5-20R 120V

 

14.4

0

13.2

5 amps/receptacle

12.0

10 amps/receptacle

 

 

10.8

15 amps/receptacle

 

 

9.6

20 amps/receptacle

 

 

Table 10. 3Ø Generator Maximum Amps

KVA in Use

Available Load

(UVWO Terminals)

Current (Amps)

3Ø 240/480V

GFCI Duplex

5-20R 120V

 

25

0 amps/receptacle

 

 

20.8

5 amps/receptacle

 

 

16.7

10 amps/receptacle

 

 

12.5

15 amps/receptacle

 

 

8.4

20 amps/receptacle

 

 

page 24 — DCA25Usi2 60 hz Generator • operation and parts manual — rev. #0 (02/14/14)

Image 24
Contents Model dca25USI2 Proposition 65 warning Reporting Safety Defects AdministratorTable of Contents DCA25USI2 60 Hz GeneratorChoose from three easy options Safety Information SaFetY messagesGeneral saFetY Generator SafetyRestricted. If the air fl ow is If operating in speed ranges above the maximum allowableFUel saFetY „ never use fuel as a cleaning agentFrom fuel vapors or if fuel is spilled on a hot engine EleCtriCal saFetY Power Cord/Cable safetyGrounding Safety BatterY saFetYEnvironmental saFetY/DeCommissioning Emissions inFormationEmission Control label Label must remain with the engine for its entire lifeSpecifications DCA25USI2Dimensions DimensionsInstallation Typical Generator Grounding ApplicationOutdoor Installation Indoor InstallationMounting Generator GroundingGeneral Information Major Components Item noGenerator Control Panel Generator Control PanelEngine Operating Panel Fuel Gauge Indicates amount of diesel fuel availableOutput Terminal Panel Familiarization Output Terminal FamiliarizationTerminal legs O and Ground are considered bonded grounds Output Terminal Panel is provided with the following Removing the Plastic Face Plate Hard Wire Hookup Panel VAC Gfci ReceptaclesConnecting Loads Over Current RelaySingle Phase Load Three Phase LoadLoad Application Generator Outputs How to Read the ac ammeter and ac voltage gauges Generator OUTPUTS/gauge readingAC Voltmeter Gauge Reading AC Ammeter Gauge ReadingOutput Terminal Panel Connections Uvwo Terminal Output Voltages3Ø-240/139 Uvwo Terminal Output Voltages 3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages3Ø-480/277V Uvwo Terminal Output Voltages 1Ø-240/120V Uvwo Terminal Output VoltagesInspection/SETUP Circuit BreakersLubrication Oil Fuel CheckRefueling Procedure Only use #2 diesel fuel when refuelingCleaning the Radiator Air Cleaner Fan Belt TensionCoolant Antifreeze/Summer Coolant/ Water Operation in Freezing WeatherBattery Battery Cable InstallationWiring AlternatorGenerator START-UP Procedure Before StartingStarting Engine’s exhaust contains harmful emissionsCoolant Temperature Gauge Generator SHUT-DOWN Procedures Normal Shutdown ProcedureEmergency Shutdown Procedure Never stop the engine suddenly except in an emergencyMaintenance General Inspection Air CleanerAir Cleaner with Dust Indicator Cleaning Inside the Fuel Tank Fuel AdditionRemoving Water from the Fuel Tank Fuel Tank InspectionRadiator Cleaning Check Oil LevelReplacing Oil Filter Flushing Out Radiator and Replacing CoolantTrailer Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Brake Adjustment BrakesHydraulic Surge Brakes ActuatorTires/Wheels/Lug Nuts Tire Wear/InflationSuspension Lug Nut Torque Requirements Never use an pneumatic air gun to tighten wheel lug nutsTrailer Wiring Diagram Trailer/Towing Vehicle Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramTroubleshooting Generator Explanation of Code in Remarks Column Suggested Spare Parts To 3 unitsGenerator Assy B1110200602 79610250040601822630 8001070003Control box Assy M1213001002 M12130010120601808820 0601807520Control box Assy M1223000603 M12230006130601807641 0601808985 AC Meter ~50A/100A5A1 0601801040Engine and Radiator Assy M1923200124 89723093902944566410 M1305200304Engine and Radiator Assy 0603300285 06033002860605511395 0605511399Output Terminal Assy 12A 11B 11A 13B 13C 13A 24A 25AM1230700003 M9220000004M9220000104 0039308000Battery Assy 0602220185 M9310500014M9103000304 0602220920Muffler Assy M1330000512 M1333200304M1333300204 M1333003013Fuel Tank Assy M1365000302 06055050700605501071 0605516090Enclosure Assy 72A 54A 56A 59A 56B 58A 52AM1413003402 M1419300504M1415100202 0603306797Enclosure Assy 0207006000 M144330220334A M1493305104 M1443400103Enclosure Assy 52A M1493410104 M145300490353A M1493409904 53B M1495501004Rubber Seals Assy REMArks Nameplate and Decals Assy M1510300902 M11030090M1510301002 M11030100Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help