Multiquip dca25USI2 manual Coolant Temperature Gauge

Page 33

GENERATOR START-UP PROCEDURE

6.The generator’s AC-voltmeter (Figure 42) will display the generator’s output in VOLTS..

10.The coolant temperature gauge (Figure 46) will indicate the coolant temperature. Under normal operating conditions the coolant temperature should be between 167°~203°F (75°~95°C) (Green Zone).

Figure 42. Frequency Meter

7.If the voltage is not within the specified tolerance use the voltage adjustment control knob (Figure 43) to increase or decrease the desired voltage.

Figure 46. Coolant Temperature Gauge

11.The tachometer gauge (Figure 47) will indicate the speed of the engine when the generator is operating. Under normal operating conditions this speed is approximately 1800 RPM’s.

Figure 43. Voltage Adjust Control Knob

8.The ammeter (Figure 44) will indicate zero amps with no load applied. When a load is applied, the ammeter will indicate the amount of current that the load is drawing from the generator.

Figure 44. Ammeter (No Load)

9.The engine oil pressure gauge (Figure 45) will indicate the oil pressure of the engine. Under normal operating conditions the oil pressure is approximately 42 to 71 psi. (290~490 kPa).

Figure 47. Engine Tachometer Gauge

12.Place the main, GFCI, and aux. circuit breakers in the ON position (Figure 48).

Figure 48. Main, Aux. and GFCI

Circuit Breakers (ON)

13.Observe the generator’s ammeter (Figure 49) and verify it reads the anticipated amount of current with respect to the load. The ammeter will only display a current reading if a load is in use.

Figure 45. Oil Pressure Gauge

Figure 49. Ammeter (Load)

14.The generator will run until manually stopped or an abnormal condition occurs.

DCA25usi2 60 hz Generator • operation and parts manual — rev. #0 (02/04/14) — page 33

Image 33
Contents Model dca25USI2 Proposition 65 warning Administrator Reporting Safety DefectsDCA25USI2 60 Hz Generator Table of ContentsChoose from three easy options SaFetY messages Safety InformationGenerator Safety General saFetYIf operating in speed ranges above the maximum allowable Restricted. If the air fl ow isFUel saFetY „ never use fuel as a cleaning agentFrom fuel vapors or if fuel is spilled on a hot engine Power Cord/Cable safety EleCtriCal saFetYGrounding Safety BatterY saFetYEmissions inFormation Environmental saFetY/DeCommissioningEmission Control label Label must remain with the engine for its entire lifeDCA25USI2 SpecificationsDimensions DimensionsTypical Generator Grounding Application InstallationIndoor Installation Outdoor InstallationMounting Generator GroundingGeneral Information Item no Major ComponentsGenerator Control Panel Generator Control PanelFuel Gauge Indicates amount of diesel fuel available Engine Operating PanelOutput Terminal Familiarization Output Terminal Panel FamiliarizationTerminal legs O and Ground are considered bonded grounds Output Terminal Panel is provided with the followingVAC Gfci Receptacles Removing the Plastic Face Plate Hard Wire Hookup PanelOver Current Relay Connecting LoadsSingle Phase Load Three Phase LoadLoad Application Generator Outputs Generator OUTPUTS/gauge reading How to Read the ac ammeter and ac voltage gaugesAC Voltmeter Gauge Reading AC Ammeter Gauge ReadingUvwo Terminal Output Voltages Output Terminal Panel Connections3Ø-240/139 Uvwo Terminal Output Voltages 3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages1Ø-240/120V Uvwo Terminal Output Voltages 3Ø-480/277V Uvwo Terminal Output VoltagesCircuit Breakers Inspection/SETUPLubrication Oil Fuel CheckOnly use #2 diesel fuel when refueling Refueling ProcedureAir Cleaner Fan Belt Tension Cleaning the RadiatorCoolant Antifreeze/Summer Coolant/ Water Operation in Freezing WeatherBattery Cable Installation BatteryWiring AlternatorBefore Starting Generator START-UP ProcedureStarting Engine’s exhaust contains harmful emissionsCoolant Temperature Gauge Normal Shutdown Procedure Generator SHUT-DOWN ProceduresEmergency Shutdown Procedure Never stop the engine suddenly except in an emergencyMaintenance General Inspection Air CleanerAir Cleaner with Dust Indicator Fuel Addition Cleaning Inside the Fuel TankRemoving Water from the Fuel Tank Fuel Tank InspectionCheck Oil Level Radiator CleaningReplacing Oil Filter Flushing Out Radiator and Replacing CoolantTrailer Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Brakes Brake AdjustmentHydraulic Surge Brakes ActuatorTires/Wheels/Lug Nuts Tire Wear/InflationSuspension Never use an pneumatic air gun to tighten wheel lug nuts Lug Nut Torque RequirementsTrailer/Towing Vehicle Wiring Diagram Trailer Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramTroubleshooting Generator Explanation of Code in Remarks Column To 3 units Suggested Spare PartsGenerator Assy 7961025004 B11102006020601822630 8001070003Control box Assy M1213001012 M12130010020601808820 0601807520Control box Assy M1223000613 M12230006030601807641 0601808985 AC Meter ~50A/100A5A1 0601801040Engine and Radiator Assy 8972309390 M19232001242944566410 M1305200304Engine and Radiator Assy 0603300286 06033002850605511395 060551139912A 11B 11A 13B 13C 13A 24A 25A Output Terminal AssyM9220000004 M1230700003M9220000104 0039308000Battery Assy M9310500014 0602220185M9103000304 0602220920Muffler Assy M1333200304 M1330000512M1333300204 M1333003013Fuel Tank Assy 0605505070 M13650003020605501071 060551609072A 54A 56A 59A 56B 58A 52A Enclosure AssyM1419300504 M1413003402M1415100202 0603306797Enclosure Assy M1443302203 020700600034A M1493305104 M1443400103Enclosure Assy M1453004903 52A M149341010453A M1493409904 53B M1495501004Rubber Seals Assy REMArks Nameplate and Decals Assy M11030090 M1510300902M1510301002 M11030100Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

dca25USI2 specifications

The Multiquip DCA25USI2 is a powerful and versatile portable generator designed for a range of applications in construction, events, and emergency power supply. This model is particularly noted for its durability and reliability, making it an excellent choice for both professionals and DIY enthusiasts.

At the heart of the DCA25USI2 is a robust 25 kW output, giving users plenty of power to run multiple tools, equipment, or systems simultaneously. This generator operates on a powerful water-cooled diesel engine, which not only enhances fuel efficiency but also extends the lifecycle of the machine compared to traditional gas-powered generators. The use of diesel fuel contributes to lower operational costs and makes it suitable for longer usage periods, particularly in remote locations.

One of the standout features of the DCA25USI2 is its compact design. Despite its high power output, this generator maintains a relatively small footprint, allowing for easy transportation and storage. Weighing around 1,800 pounds, it is fitted with a robust frame that provides durability while facilitating easy placement at job sites or outdoor events.

The generator is equipped with advanced noise reduction technology, ensuring that it operates quietly, which is crucial when working in residential areas or noise-sensitive environments. The sound-dampening enclosure significantly lowers operating noise levels, enhancing the overall user experience.

In terms of electrical output, the DCA25USI2 offers multiple options, including both single-phase and three-phase connections. This versatility allows users to power a variety of applications without needing additional adaptors. Moreover, the generator’s heavy-duty alternator ensures stable power delivery, protecting sensitive electronic devices from voltage spikes.

Another key characteristic of the DCA25USI2 is its user-friendly control panel, which features intuitive gauges and circuit breakers for easy management of power distribution. The panel includes a digital hour meter, allowing operators to track usage and plan for maintenance efficiently.

Safety features are also a priority with the DCA25USI2, including automatic shutdown capabilities to protect the engine against low oil levels and overheating. This thoughtful design helps to ensure both the performance and longevity of the generator.

In summary, the Multiquip DCA25USI2 stands out for its powerful output, efficient diesel engine, compact design, and advanced features, making it a top choice for anyone in need of reliable portable power. Whether for construction, events, or emergency backup, this generator is engineered to deliver exceptional performance and peace of mind.