Multiquip DCA125SSIU Trailer Maintenance, Coupler Type of hitch used on the trailer for towing

Page 42

TRAILER MAINTENANCE

TRAILER MAINTENANCE

This section is intended to provide the user with generic trailer service and maintenance information. The service and maintenance guidelines referenced in this section refer to a wide range of trailers.

Remember periodic inspection of the trailer will ensure safe towing of the generator and will prevent personal injury and damage to the equipment.

The definitions below describe some of the major components of a typical trailer that would be used with generator.

1.Fuel Cell — Provides an adequate amount of fuel for the equipment in use. Fuel cells must be empty when transporting equipment.

2.Braking System — System employed in stopping the trailer. Typical braking systems are electric, surge, hydraulic, hydraulic-surge and air.

3.GVWR — Gross Vehicle Weight Rating (GVWR) is the maximum number of pounds the trailer can carry, including the fuel cell (empty).

4.Frame Length — Measurement is from the ball hitch to the rear bumper (refl ector).

5.Frame Width — Measurement is from fender to fender

6.Jack Stand — Trailer support device with maximum pound requirement from the tongue of the trailer.

7.Coupler — Type of hitch used on the trailer for towing.

8.Tire Size — Indicates the diameter of the tire in inches (10,12,14, etc.), and the width in millimeters (175,185,205, etc.). The tire diameter must match the diameter of the tire rim.

9.Tire Ply — The tire ply (layers) number is rated in letters; 2-ply,4-ply,6-ply, etc.

10.Wheel Hub — The wheel hub is connected to the trailer’s axle.

11.Tire Rim — Tires mounted on a tire rim. The tire rim must match the size of the tire.

12.Lug Nuts — Used to secure the wheel to the wheel hub. Always use a torque wrench to tighten down the lug nuts. See Table 18 and Figure 62 for lug nut tightening and sequence.

13.Axle — Indicates the maximum weight the axle can support in pounds, and the diameter of the axle expressed in inches. Please note that some trailers have a double axle. This will be shown as 2-6000 lbs., meaning two axles with a total weight capacity of 6000 pounds.

14.Suspension — Protects the trailer chassis from shocks transmitted through the wheels. Types of suspension used are leaf, Q-fl ex, and air ride.

15.Electrical — Electrical connectors (looms) are provided with the trailer so the brake lights and turn signals can be connected to the towing vehicle.

16.Application — Indicates which units can be employed on a particular trailer.

PAGE 42 — DCA125SSIU 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #3 (01/13/11)

Image 42
Contents Model DCA125SSIU This Manual Must Accompany the Equipment AT ALL TimesProposition 65 Warning Reporting Safety Defects AdministratorTable of Contents DCA125SSIU GeneratorParts Ordering Procedures Ordering parts has never been easierSafety Information Safety MessagesGeneral Safety Generator Safety Always know the location of the nearest Engine Safety Before servicing equipment Never use fuel as a cleaning agent Fuel SafetyTowing Safety From fuel vapors or if fuel is spilled on a hot enginePower Cord/Cable Safety Electrical SafetyGrounding Safety Device. All installations should beBattery Safety Environmental SafetySpecifications DCA-125SSIUDimensions DimensionsInstallation Typical Generator Grounding ApplicationMounting Outdoor InstallationIndoor Installation Generator GroundingGeneral Information Assembly Major ComponentsGenerator Control Panel Owing from the U,V, and W Output Terminal Lugs to the loadPage Engine Operating Panel Engine Operating PanelEngine Speed Switch This switch controls the speed Fuel Gauge Indicates amount of diesel fuel availableOutput Terminal Panel Familiarization Output Terminal FamiliarizationTerminal legs O and Ground are considered bonded grounds VAC Gfci Receptacles 240V Twist-Lock Auxiliary ReceptaclesConnecting Loads Over Current RelaySingle Phase Load Three Phase LoadLoad Application Generator Outputs Generator Output VoltagesGenerator OUTPUTS/GAUGE Reading Reading VoltageReading Amperage 3Ø-240/139 Uvwo Terminal Output Voltages Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages3Ø-480/277V Uvwo Terminal Output Voltages 1Ø-240/120V Uvwo Terminal Output VoltagesLubrication OIL INSPECTION/SETUPCircuit Breakers Fuel CheckRefueling Procedure Only use #2 diesel fuel when refuelingCoolant ANTIFREEZE/SUMMER COOLANT/ Water Cleaning the RadiatorAIR Cleaner FAN Belt Tension Operation in Freezing WeatherWiring BatteryBattery Cable Installation AlternatorBefore Starting Generator START-UP Procedure ManualPlace the engine speed switch in the LOW down position Starting ManualFrequency Meter Generator START-UP Procedure Auto Mode Starting Auto ModeEmergency Shutdown Procedure Generator SHUT-DOWN ProceduresNormal Shutdown Procedure Never stop the engine suddenly except in an emergencyMaintenance General Inspection AIR CleanerAir Cleaner with Dust Indicator Fuel Addition Fuel Tank InspectionAIR Removal Replacing Oil Filter Radiator CleaningCheck OIL Level Flushing OUT Radiator and Replacing CoolantBattery Charger and Jacket Water Heater Power Connections Trailer Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Hydraulic Surge Brakes Brake AdjustmentBrakes ActuatorTIRES/WHEELS/LUG Nuts Tire Wear/InflationSuspension Tighten each lug nut in 3 separate passes as defi ned Lug Nut Torque RequirementsStart all wheel lug nuts by hand Never use an pneumatic air gun to tighten wheel lug nutsTrailer Wiring Diagram Trailer/Towing Vehicle Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramController Wiring Diagram Controller Wiring DiagramTroubleshooting Generator Troubleshooting Engine Controller Troubleshooting Diagnostic Lamp Method of OperationPage Sample Parts List Explanation of Code in Remarks ColumnSuggested Spare Parts To 3 unitsGenerator Assy 8131611014 C01100010028131070013 8131015003Control BOX Assy 0330000280 M32130017020330000210 0330000180Control BOX Assy 8970119490 00271060165825500290 M3213500604Control BOX Assy 0080200007 0027105010M9220100004 0602122272Engine and Radiator Assy M3303200603 M39232001348980527130 0010310025Engine and Radiator Assy M3323500004 06020210700269200600 0016910025Output Terminal Assy M9220100404 M3230700003M9220100304 0039316000Battery Assy M9103000504 0602220198M9310500404 0602220921Muffler Assy 1141451840 M3330100902M3333001403 M3333200004Fuel Tank Assy 0605501076 M33630020020605505070 0605516090Enclosure Assy M3423002702 M3413002402M1413400004 M3493114303Enclosure Assy 0037906000 M3443200703M3443600104 36A 0041206000Enclosure Assy 66A M9116100004 0600800320M3453700004 M9110100304Rubber Seals Assy 0228900990 02292011000228900880 0228901050Nameplate and Decals Assy M9520100304 M3550003003M35000300A M92010030Nameplate and Decals Assy M9510200002 M9500500004M9500500104 060050090Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help
Related manuals
Manual 88 pages 9.93 Kb

DCA125SSIU specifications

The Multiquip DCA125SSIU is a robust and versatile diesel generator that is designed to meet the power needs of various applications, from construction sites to events and emergency situations. With a power output of 125 kVA, this generator combines efficiency and reliability, making it an ideal choice for professionals who demand optimal performance in challenging environments.

One of the primary features of the DCA125SSIU is its industrial-grade a diesel engine. This engine not only delivers impressive power but also emphasizes fuel efficiency. The generator is equipped with advanced fuel management technologies that help minimize consumption while maximizing output, making it cost-effective for long-term use.

In terms of durability, the DCA125SSIU is built with a sturdy enclosure that protects it from environmental factors. The weather-resistant design ensures that it operates effectively in a variety of weather conditions, ensuring reliable performance when needed the most. Additionally, its compact size allows for easy transport and storage, which is particularly beneficial for contractors and rental companies.

The DCA125SSIU features a user-friendly control panel that provides essential information at a glance. This panel includes gauges for monitoring key parameters such as voltage, frequency, and hours of operation. It also has an automatic voltage regulator (AVR) that maintains consistent voltage output, safeguarding connected equipment from potential damage caused by power fluctuations.

Safety is a priority with the DCA125SSIU, as it is equipped with several emergency shutdown features. These include low oil pressure, high temperature, and overload protection, ensuring that the generator operates safely under all conditions. Further enhancing its operational reliability, the generator comes with a built-in fuel tank that allows for extended runtime, reducing the frequency of refueling during use.

In summary, the Multiquip DCA125SSIU is a powerful, durable, and efficient diesel generator that meets the diverse power needs of various industries. Its combination of a high-performance engine, user-friendly control panel, robust safety features, and fuel efficiency makes it an exceptional choice for anyone looking for a reliable power solution. Whether for temporary power during events, backup for critical systems, or support at construction sites, the DCA125SSIU is engineered to perform.