Multiquip operation manual GA-3.6RZ3 Load Application

Page 15

Single Phase Load

GA-3.6RZ3 — LOAD APPLICATION

CAUTION:

Always be sure to check the nameplate on the generator and equipment to insure the wattage, amperage and frequency requirements are satisfactorily supplied by the generator for operating the equipment.

Generally, the wattage listed on the nameplate of the equipment is its rated output. Equipment may require 130— 150% more wattage than the rating on the nameplate, as the wattage is influenced by the efficiency, power factor and starting system of the equipment.

NOTE

If wattage is not given on the equipment's name plate, approximate wattage may be determined by multiplying nameplate voltage by the nameplate amperage.

WATTS = VOLTAGE x AMPERAGE

To determine the running wattage for your load, multiply the running wattage as indicated by steps 1, 2, and 3 below:

1.INCANDESCENT LOADS

Lights, heaters and similar appliances. Total the running wattage and multiply by 1. Example:

29 light bulbs @ 100W each = 2.9 KW use a 3 KW generator.

2.SMALL MOTORS

Drills and other small power tools.

Total the running wattage and multiply by 2. Example:

A 1 inch drill runs at 1 KW use a 2 KW generator.

3.LARGE MOTORS

Submersible pumps, table saws etc.

Total the running wattage and multiply by 3. Example:

A conveyor belt runs at 8 KW use a 24 KW generator.

Motors and motor-driven equipment draw much greater current for starting than during operation.

An inadequate size connecting cable which cannot carry the required load can cause a voltage drop which can burn out the appliance or tool and overheat the cable.

The idle control is operated at minimum load capacity of 100W. If the load capacity is less than 100W, throw the idle control switch to the OFF position.

GA-3.6RZ3 A.C. GENERATOR — PARTS & OPERATION MANUAL — REV. #3 (09/03/04) — PAGE 15

Image 15
Contents Multiquip Page Heres HOW to GET Help Table of Contents UPS Ground Service at no charge for freight Parts Ordering ProceduresMaintenance Safety Rules for Safe OperationEmergencies Machine Safety Decals Operation and Safety DecalsSpecifications GA-3.6RZ3 General Information Controls and Indicators GA-3.6RZ3 Controls and IndicatorsGA-3.6RZ3 Installation Outdoor InstallationIndoor Installation Ground GA-3.6RZ3 PRE-SETUPGeneral Inspection Prior to Operation Circuit BreakerFuel Lubrication OilGA-3.6RZ3 Instrumentation Power OutletsStart Switch Full Power SwitchGA-3.6RZ3 Load Application Before Starting GA-3.6RZ3 Operating InstructionsSpark Plug Gap GA-3.6RZ3 MaintenanceGenerator Storage GA-3.6RZ3 Preparation for Long -TERM StorageGenerator Engine GA-3.6RZ3 -WIRING DiagramEngine Troubleshooting Symptom Possible Problem Solution GA-3.6RZ3 -TROUBLESHOOTING EngineGA-3.6RZ3 -TROUBLESHOOTING Engine GA-3.6RZ3 -TROUBLESHOOTING Generator GA-3.6RZ3 -TROUBLESHOOTING Generator Items Found In the Items Number Column GA-3.6RZ3 Explanation of Code in Remarks ColumnTo 5 Units To 10 Units GA-3.6RZ3 Suggested Spare PartsGA-3.6RZ3 Generator Assy Bearing GA-3.6RZ3 Control BOX Assy Replaces GA-3.6RZ3 Pipe Frame Assy Bracket GA-3.6RZ3 Name Plate and Decals See Decal Illustrations on Robin EH-25 Engine Crankcase Assy Part Name QTY Remarks Robin EH-25 Engine Crankshaft & Piston Assy NUT Robin EH-25 Engine Intake & Exhaust Assy Tappet Robin EH-25 Engine Governor Assy Governor ROD Robin EH-25 Engine Cooling & Starting Assy Label Trade Mark Robin EH-25 Engine Carburetor Assy Hose Clamp Robin EH-25 Engine Ignition Coil ASSY. and Spark Plug FLY Wheel Robin EH-25 Engine Fuel Strainer Robin EH-25 Engine Fuel Strainer Freightpolicy Terms and Conditions of Sale PartsPage Denyo Manufacturing CO., Japan Multiquip INC