Multiquip DCA-220SSVU operation manual Maintenance Safety, Battery Safety

Page 12

DCA-220SSVU (50 HZ) — RULES FOR SAFE OPERATION

Maintenance Safety

The electrical voltage required to operate the generator can cause severe injury or even death through physical contact with live circuits. Turn all circuit breakers OFF before performing maintenance on the generator.

NEVER lubricate components or attempt service on a running machine.

ALWAYS disconnect the NEGATIVE battery terminal before performing service on the generator.

Follow all Battery Safety Guidelines listed in this manual when handleing or servicing the generator.

ALWAYS allow the machine a proper amount of time to cool before servicing.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and always replace broken parts.

ALWAYS service air cleaner frequently to prevent engine malfunction.

WARNING - BURN HAZARDS

To prevent burns, DO NOT touch or open any of the below mentioned components while the engine is

running or immediately after operations. Always allow sufficient time for the engine and generator to cool before performing maintenance.

Radiator Cap - Removing the radiator cap while the engine is hot will result in high pressurized, boiling water to gush out of the radiator, causing severe scalding to any persons in the general area of the generator.

Coolant Drain Plug - Removing the coolant drain plug while the engine is hot will result in hot coolant gushing out of the coolant drain plug, therefore causing severe scalding to any persons in the general area of the generator.

Engine Oil Drain Plug - Removing the engine oil drain plug while the engine is hot will result in hot oil gushing out of the oil drain plug, therefore causing severe scalding to any persons in the general area of the generator.

Battery Safety

Use the following guidelines when handling the battery:

The battery contains acids that can cause injury to the eyes and skin. To avoid eye irritation, always wear safety glasses.

Use well insulated gloves when picking up the battery.

DANGER - EXPLOSION HAZARDS

The risk of an explosion exists when performing service on the battery. To avoid severe injury or DEATH:

DO NOT drop the battery.There is the possibility of risk that the battery may explode.

DO NOT expose the battery to open flames, sparks, cigarettes

etc.The battery contains combustible gases and liquids. If these gases and liquids come in contact with a flame or spark, an explosion could occur.

ALWAYS keep the battery charged. If the battery is not charged a buildup of combustible gas will occur.

ALWAYS keep battery charging and cables in good working condition. Repair or replace all worn cables.

ALWAYS recharge the battery in an vented air environment, to avoid risk of a dangerous concentration of combustible gases.

In case the battery liquid (dilute sulfuric acid) comes in contact with clothing or skin, rinse skin or clothing immediately with plenty of water.

In case the battery liquid (dilute sulfuric acid) comes in contact with your EYES, rinse eyes immediately with plenty of water and contact the nearest doctor or hospital to seek medical attention.

PAGE 12 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)

Image 12
Contents Parts List NO. M4870300024A Model DCA-220SSVUPage Heres HOW to GET Help Wilmington Ave Carson, CADCA-220SSVU 50 HZ Table of Contents DCA-220SSVU 50 HZ Parts Ordering Procedures When ordering parts Please supply the following informationDCA-220SSVU 50 HZ Specifications DCA-220SSVU 50 HZ Dimensions TOP, Side and Front DimensionsDCA-220SSVU 50 HZ Safety Message Alert Symbols Hazard SymbolsDCA-220SSVU 50 HZ Safety Message Alert Symbols This generator, other property, orGeneral Safety DCA-220SSVU 50 HZ Rules for Safe OperationElectrical Safety DCA-220SSVU 50 HZ Rules for Safe OperationGenerator Grounding Maintenance Safety Battery SafetyTowing &Transporting Safety EmergenciesDCA-220SSVU 50 HZ Generator Decals Generator DecalsDCA-220SSVU 50 HZ Generator Decals Generator Decals Cont inuedDCA-220SSVU 50 HZ Installation DCA-220SSVU 50 HZ Installation Outdoor InstallationIndoor Installation When connecting the generatorDCA-220SSVU 50 HZ General Information DCA-220SSVU 50 HZ Major Components Major ComponentsPage DCA-220SSVU 50 HZ Generator Control Panel DCA-220SSVU 50 HZ- Engine Operating Panel DCA-220SSVU 50 HZ- Engine Operating Panel Auto On/Off Engine Controller MpecDCA-220SSVU 50 HZ- Output Terminal Panel Familiarization Output Terminal FamiliarizationDCA-220SSVU 50 HZ- Output Terminal Panel Familiarization 100VAC Gfci ReceptaclesConnecting Loads Over Current RelaySingle Phase Load Three Phase LoadDCA-220SSVU 50 HZ- Load Application Motors and motor-drivenDCA-220SSVU 50 HZ Generator Outputs Generator OutputVoltagesVoltage Change-Over Board Generator AmperageHow to Read the Output Terminal Gauge DCA-220SSVU 50 HZ- Generator OUTPUTS/ Gauge ReadingDCA-220SSVU 50 HZ Output Terminal Panel Connections Uvwo Terminal Output Voltages3Ø-220V Uvwo Terminal Output Voltages 1Ø-200V Uvwo Terminal Output Voltages3Ø-440V Uvwo Terminal Output Voltages 1Ø-440V Uvwo Terminal Output Voltages1Ø-254V Uvwo Terminal Output Voltages DCA-220SSVU 50 HZ- PRE-SETUP Circuit BreakersLubrication Oil Fuel CheckDCA-220SSVU 50 HZ- PRE-SETUP Refueling ProcedureRefueling Cleaning the Radiator Air Cleaner Fan Belt TensionOperation FreezingWeather Must be less than 50%Battery Battery Cable InstallationWiring AlternatorDCA-220SSVU 50 HZ- Generator START-UP Procedure Manual Before StartingStarting Manual Coolant Temperature Gauge No LoadStarting Auto Mode Place the engine speed switch in the High positionPlace the Mpec Control Switch in the Auto position Is placed in the Auto positionNormal Shutdown Procedure Emergency Shutdown ProcedureDCA-220SSVU 50 HZ- Maintenance Cleaning the Fuel Strainer Air RemovalCheck Oil Level Replacing Oil FilterDCA-220SSVU 50 HZ- Maintenance To ensure adequate startingDCA-220SSVU 50 HZ-TRAILER Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Brake Adjustment BrakesCheck the wheel and drum for free rotation Hydraulic Surge BrakesTires/Wheels/Lug Nuts TireWear/InflationSuspension DCA-220SSVU 50 HZ-TRAILER Maintenance Lug Nut Torque RequirementsStart all wheel lug nuts by hand DCA-220SSVU 50 HZ-TRAILERWIRING Diagram Trailer/Towing Vehicle Wiring DiagramDCA-220SSVU 50 HZ- Generatorwiring Diagram Generator Wiring DiagramDCA-220SSVU 50 HZ Enginewiring Diagram Engine Wiring DiagramDCA-220SSVU 50 HZ-TROUBLESHOOTING Generator Generator TroubleshootingDCA-220SSVU 50 HZ-TROUBLESHOOTING Engine Controller Engine Controller Troubleshooting MpecSample Parts List DCA-220SSVU 50 HZ Explanation of Code in Remarks ColumnPart number on this Suggested Spare Parts list DCA-220SSVU 50 HZ- Suggested Spare PartsDCA-220SSVU 50 HZ- Generator Assy C1110000002 06018423340601823282 0018205020DCA-220SSVU 50 HZ- Generator ASSY. 0012110065 10A 004261000010B 0041210000 0017112045DCA-220SSVU- Control Panel Assy DCA-220SSVU- Control Panel Assy DCA-220SSVU- Control BOX Assy M4213000012 06018096900027106016 0601870420DCA-220SSVU- Control BOX ASSY. 31A 0601823109 31B 06018244000601822060 32A 0601823143DCA-220SSVU- Engine and Radiator Assy M4386200004 V466634V477556 V3825133DCA-220SSVU- Engine and Radiator Assy 0605515109 02694017000605515199 M4483600003DCA-220SSVU- Outputterminal Assy Output Terminal AssyM4230700003 M9220100304M9220100404 0039316000DCA-220SSVU- Battery Assy 0602220196 M9310500404M9103000504 0602220921DCA-220SSVU- Muffler Assy M4330100002 M4333000003V424628 M4333200004DCA-220SSVU- Fueltank Assy M4363000002 0605505070M4363200004 M9310500104DCA-220SSVU- Enclosure Assy Enclosure AssyM4413000002 M4493000004M1413400004 M4423000102DCA-220SSVU- Enclosure ASSY. Enclosure ASSY.0021806016 25A 0030006000M9110100204 26A M9116100004DCA-220SSVU- Rubber Seals Assy 0229201300 02289010100228901200 0228901050DCA-220SSVU- Nameplate and Decals Assy M3552000103 M9520100304M9520100603 M4550000012Terms and Conditions of Sale Parts FreightpolicyPage Your Local Dealer is
Related manuals
Manual 84 pages 27.37 Kb Manual 86 pages 53.52 Kb

DCA-220SSVU specifications

The Multiquip DCA-220SSVU is a robust and versatile generator, designed for both commercial and industrial applications. It is particularly renowned for its reliability, efficiency, and advanced features tailored to meet the demands of various worksites.

At its core, the DCA-220SSVU is a silent diesel generator, powered by a dependable Yanmar engine. This engine not only provides impressive performance but also ensures durability, making it a popular choice for operations that require continuous power supply. With a power output capacity of 220 kVA, this generator can effortlessly handle heavy-duty equipment and multiple power needs simultaneously.

One of the standout features of the DCA-220SSVU is its sound attenuation technology. Enclosed in a weather-proof canopy, the generator significantly minimizes noise output, making it an ideal option for locations with strict noise regulations, such as residential areas or sensitive environments. The generator operates at a low noise level, allowing it to blend seamlessly into various settings without causing disruption.

The Multiquip DCA-220SSVU also boasts advanced fuel efficiency. It is engineered to consume lesser fuel while providing maximum output, leading to reduced operational costs for users. This efficiency not only helps in cost savings but also minimizes the environmental impact, aligning with contemporary sustainability practices.

Another characteristic that sets the DCA-220SSVU apart is its user-friendly operation. The generator comes equipped with a digital control panel that displays critical information, including voltage, frequency, and runtime. This feature enables operators to monitor performance easily and perform quick troubleshooting when necessary.

Safety is paramount with the DCA-220SSVU, which is equipped with various protective features. These include low oil pressure shutdown, high coolant temperature shutdown, and overcurrent protection, ensuring that the generator operates safely and efficiently under varying load conditions.

Additionally, the generator features a large fuel tank that allows for extended run times, making it suitable for long-term projects or emergency situations. The DCA-220SSVU is engineered for enhanced mobility, thanks to its sturdy frame and integrated lifting points, allowing it to be transported easily across different job sites.

In conclusion, the Multiquip DCA-220SSVU is a powerful, efficient, and quiet generator that incorporates advanced technologies, comprehensive safety features, and user-friendly controls. Ideal for contractors and businesses looking for reliable power solutions, this generator exemplifies Multiquip's commitment to quality and innovation in the construction and industrial sectors.