Multiquip DCA-220SSVU operation manual Towing &Transporting Safety, Emergencies

Page 13

DCA-220SSVU (50 HZ) — RULES FOR SAFE OPERATION

Towing &Transporting Safety

To reduce the possibility of an accident while transporting the generator on public roads, always make sure the trailer that supports the generator and the towing vehicle are in good operating condition and both units are mechanically sound.

The following list of safety precautions should be followed when towing your generator:

CAUTION - FOLLOWTOWING REGULATIONS

Check with your local county or state safety towing regulations, in addition to meeting Department of Transportation (DOT) SafetyTowing Regulations, before towing your generator.

ALWAYS shutdown engine before transporting.

Tighten both fuel tank caps securely.

If generator is mounted on a trailer, make sure trailer complies with all local and state safety transportation laws. Follow the listed Towing & Transporting Safety guidelines for basic towing techniques.

Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer "gross vehicle weight rating.”

ALWAYS inspect the hitch and coupling for wear. NEVER tow a trailer with defective hitches, couplings, chains etc.

Check the tire air pressure on both towing vehicle and trailer. Trailer tires should be inflated to 50 psi cold. Also check the tire tread wear on both vehicles.

ALWAYS make sure the trailer is equipped with a "Safety Chain".

ALWAYS attach trailer’s safety chains to towing vehicle properly.

ALWAYS make sure the vehicle and trailer directional, backup, brake, and trailer lights are connected and working properly.

DOT Requirements include the following:

z Connect and test electric brake operation.

z Secure portable power cables in cable tray with tie wraps.

The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

Place chock blocks underneath wheel to prevent rolling, while parked.

Use the trailer’s swivel jack to adjust the trailer height to a level position while parked.

Avoid sudden stops and starts. This can cause skidding, or jack-knifing. Smooth, gradual starts and stops will improve towing.

Avoid sharp turns.

Trailer should be adjusted to a level position at all times when towing.

Raise and lock trailer wheel stand in up position when transporting.

The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

Place support blocks underneath the trailer’s bumper to prevent tipping, while parked.

Avoid sharp turns to prevent rolling.

DO NOT transport generator with fuel in tank.

Emergencies

ALWAYS know the location of the nearest fire extinguisher.

ALWAYS know the location of the nearest and first aid kit.

ALWAYS know the location of the nearest phone or keep a phone on the job site, in case of emergencies.

ALWAYS have easy access to the phone numbers of the nearest Ambulance, Doctor and Fire Department. This information will be invaluable in the case of an emergency.

DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 13

Image 13
Contents Model DCA-220SSVU Parts List NO. M4870300024APage Wilmington Ave Carson, CA Heres HOW to GET HelpDCA-220SSVU 50 HZ Table of Contents When ordering parts Please supply the following information DCA-220SSVU 50 HZ Parts Ordering ProceduresDCA-220SSVU 50 HZ Specifications Dimensions DCA-220SSVU 50 HZ Dimensions TOP, Side and FrontHazard Symbols DCA-220SSVU 50 HZ Safety Message Alert SymbolsThis generator, other property, or DCA-220SSVU 50 HZ Safety Message Alert SymbolsDCA-220SSVU 50 HZ Rules for Safe Operation General SafetyDCA-220SSVU 50 HZ Rules for Safe Operation Electrical SafetyGenerator Grounding Battery Safety Maintenance SafetyEmergencies Towing &Transporting SafetyGenerator Decals DCA-220SSVU 50 HZ Generator DecalsGenerator Decals Cont inued DCA-220SSVU 50 HZ Generator DecalsDCA-220SSVU 50 HZ Installation Outdoor Installation DCA-220SSVU 50 HZ InstallationIndoor Installation When connecting the generatorDCA-220SSVU 50 HZ General Information Major Components DCA-220SSVU 50 HZ Major ComponentsPage DCA-220SSVU 50 HZ Generator Control Panel DCA-220SSVU 50 HZ- Engine Operating Panel Auto On/Off Engine Controller Mpec DCA-220SSVU 50 HZ- Engine Operating PanelOutput Terminal Familiarization DCA-220SSVU 50 HZ- Output Terminal Panel Familiarization100VAC Gfci Receptacles DCA-220SSVU 50 HZ- Output Terminal Panel FamiliarizationOver Current Relay Connecting LoadsThree Phase Load Single Phase LoadDCA-220SSVU 50 HZ- Load Application Motors and motor-drivenGenerator OutputVoltages DCA-220SSVU 50 HZ Generator OutputsVoltage Change-Over Board Generator AmperageDCA-220SSVU 50 HZ- Generator OUTPUTS/ Gauge Reading How to Read the Output Terminal GaugeUvwo Terminal Output Voltages DCA-220SSVU 50 HZ Output Terminal Panel Connections3Ø-220V Uvwo Terminal Output Voltages 1Ø-200V Uvwo Terminal Output Voltages1Ø-440V Uvwo Terminal Output Voltages 3Ø-440V Uvwo Terminal Output Voltages1Ø-254V Uvwo Terminal Output Voltages Circuit Breakers DCA-220SSVU 50 HZ- PRE-SETUPLubrication Oil Fuel CheckRefueling Procedure DCA-220SSVU 50 HZ- PRE-SETUPRefueling Air Cleaner Fan Belt Tension Cleaning the RadiatorOperation FreezingWeather Must be less than 50%Battery Cable Installation BatteryWiring AlternatorBefore Starting DCA-220SSVU 50 HZ- Generator START-UP Procedure ManualStarting Manual No Load Coolant Temperature GaugePlace the engine speed switch in the High position Starting Auto ModePlace the Mpec Control Switch in the Auto position Is placed in the Auto positionEmergency Shutdown Procedure Normal Shutdown ProcedureDCA-220SSVU 50 HZ- Maintenance Air Removal Cleaning the Fuel StrainerCheck Oil Level Replacing Oil FilterTo ensure adequate starting DCA-220SSVU 50 HZ- MaintenanceTrailer Maintenance DCA-220SSVU 50 HZ-TRAILER MaintenanceCoupler Type of hitch used on the trailer for towing Brakes Brake AdjustmentCheck the wheel and drum for free rotation Hydraulic Surge BrakesTireWear/Inflation Tires/Wheels/Lug NutsSuspension Lug Nut Torque Requirements DCA-220SSVU 50 HZ-TRAILER MaintenanceStart all wheel lug nuts by hand Trailer/Towing Vehicle Wiring Diagram DCA-220SSVU 50 HZ-TRAILERWIRING DiagramGenerator Wiring Diagram DCA-220SSVU 50 HZ- Generatorwiring DiagramEngine Wiring Diagram DCA-220SSVU 50 HZ Enginewiring DiagramGenerator Troubleshooting DCA-220SSVU 50 HZ-TROUBLESHOOTING GeneratorEngine Controller Troubleshooting Mpec DCA-220SSVU 50 HZ-TROUBLESHOOTING Engine ControllerDCA-220SSVU 50 HZ Explanation of Code in Remarks Column Sample Parts ListDCA-220SSVU 50 HZ- Suggested Spare Parts Part number on this Suggested Spare Parts listDCA-220SSVU 50 HZ- Generator Assy 0601842334 C11100000020601823282 0018205020DCA-220SSVU 50 HZ- Generator ASSY. 10A 0042610000 001211006510B 0041210000 0017112045DCA-220SSVU- Control Panel Assy DCA-220SSVU- Control Panel Assy DCA-220SSVU- Control BOX Assy 0601809690 M42130000120027106016 0601870420DCA-220SSVU- Control BOX ASSY. 31B 0601824400 31A 06018231090601822060 32A 0601823143DCA-220SSVU- Engine and Radiator Assy V466634 M4386200004V477556 V3825133DCA-220SSVU- Engine and Radiator Assy 0269401700 06055151090605515199 M4483600003Output Terminal Assy DCA-220SSVU- Outputterminal AssyM9220100304 M4230700003M9220100404 0039316000DCA-220SSVU- Battery Assy M9310500404 0602220196M9103000504 0602220921DCA-220SSVU- Muffler Assy M4333000003 M4330100002V424628 M4333200004DCA-220SSVU- Fueltank Assy 0605505070 M4363000002M4363200004 M9310500104Enclosure Assy DCA-220SSVU- Enclosure AssyM4493000004 M4413000002M1413400004 M4423000102Enclosure ASSY. DCA-220SSVU- Enclosure ASSY.25A 0030006000 0021806016M9110100204 26A M9116100004DCA-220SSVU- Rubber Seals Assy 0228901010 02292013000228901200 0228901050DCA-220SSVU- Nameplate and Decals Assy M9520100304 M3552000103M9520100603 M4550000012Freightpolicy Terms and Conditions of Sale PartsPage Your Local Dealer is
Related manuals
Manual 84 pages 27.37 Kb Manual 86 pages 53.52 Kb

DCA-220SSVU specifications

The Multiquip DCA-220SSVU is a robust and versatile generator, designed for both commercial and industrial applications. It is particularly renowned for its reliability, efficiency, and advanced features tailored to meet the demands of various worksites.

At its core, the DCA-220SSVU is a silent diesel generator, powered by a dependable Yanmar engine. This engine not only provides impressive performance but also ensures durability, making it a popular choice for operations that require continuous power supply. With a power output capacity of 220 kVA, this generator can effortlessly handle heavy-duty equipment and multiple power needs simultaneously.

One of the standout features of the DCA-220SSVU is its sound attenuation technology. Enclosed in a weather-proof canopy, the generator significantly minimizes noise output, making it an ideal option for locations with strict noise regulations, such as residential areas or sensitive environments. The generator operates at a low noise level, allowing it to blend seamlessly into various settings without causing disruption.

The Multiquip DCA-220SSVU also boasts advanced fuel efficiency. It is engineered to consume lesser fuel while providing maximum output, leading to reduced operational costs for users. This efficiency not only helps in cost savings but also minimizes the environmental impact, aligning with contemporary sustainability practices.

Another characteristic that sets the DCA-220SSVU apart is its user-friendly operation. The generator comes equipped with a digital control panel that displays critical information, including voltage, frequency, and runtime. This feature enables operators to monitor performance easily and perform quick troubleshooting when necessary.

Safety is paramount with the DCA-220SSVU, which is equipped with various protective features. These include low oil pressure shutdown, high coolant temperature shutdown, and overcurrent protection, ensuring that the generator operates safely and efficiently under varying load conditions.

Additionally, the generator features a large fuel tank that allows for extended run times, making it suitable for long-term projects or emergency situations. The DCA-220SSVU is engineered for enhanced mobility, thanks to its sturdy frame and integrated lifting points, allowing it to be transported easily across different job sites.

In conclusion, the Multiquip DCA-220SSVU is a powerful, efficient, and quiet generator that incorporates advanced technologies, comprehensive safety features, and user-friendly controls. Ideal for contractors and businesses looking for reliable power solutions, this generator exemplifies Multiquip's commitment to quality and innovation in the construction and industrial sectors.