LSI DF1153-E1 manual About This Book, Intended Readers

Page 9

About This Book

This book provides technical specifications and information you will need to prepare a site before installing the following hardware:

E3300 Drive Module containing up to ten drives and one low-voltage-differential- to- single-ended environmental services monitor (LVD-SE ESM),

E3300 Drive Module containing up to ten drives and one LVD-LVD ESM

FC-1 10x Drive Module containing up to ten drives and one or two Fibre-Channel-to- Fibre-Channel (FC-FC) ESMs

E2400 10x Command Module containing up to ten drives and one or two 2772 controllers

FC-1 14x Drive Module containing up to fourteen drives and one or two FC-FC ESMs

E2400 14x Command Module containing up to fourteen drives and one or two 2772 controllers

Intended Readers

This book is intended for end users, system operators, system administrators, and service technicians who are responsible for preparing and installing hardware. Readers should understand the following technologies:

Redundant array of independent disk (RAID)

Small computer systems interface (SCSI)

Fibre Channel

Drive Module Site Preparation Guide

1

Image 9
Contents Drive Module Trademark Acknowledgments Drive Module Site Preparation Guide Part Number DF1153-E1 Contents Drive Module Site Preparation Guide List of Figures List of Tables Intended Readers About This BookTerminology Used in This Book Content and OrganizationController module or controller tray Term Definition Usage ExamplesGeneral Documentation Documentation SetHardware Documentation Software DocumentationTools and Equipment You May Need Preparatory TasksArea Requirements WeightsESM Unit Maximum1 Unit Empty2 Unit Shipping3 WeightKg 3.8 lb Command Module, deskside Unit Maximum Unit Drive-Ready Shipping Weight1 Unit Maximum Unit Empty Unit Shipping Weight2 Weight3Dimensions E3300 Drive Module Dimensions Drive Module Site Preparation Guide Unit Carton Height Carton Width Carton Depth Airflow Drive Module or E2400 Command Module AirflowElement Unit of Measure E3300 and FC-1 FC-1 14x and E2400 Environmental RequirementsDrive Module and E2400 Command Module Heat Dissipation Site Wiring and Voltages Site Wiring RequirementsNominal Minimum Input Power 50 Hz 60 HZ Nominal MinimumE3300 Drive Module Drive Module Power RequirementsUnit of Measure Requirement InternationalPower Cord Routing USA FC-1 10x Drive Module and E2400 10x Command ModuleDrive Module Power Supplies Command AC Distribution Boxes FC-1 14x Drive Module and E2400 14x Command Module Power Cord Routing E3300 Interface Cables Drive Module Cable RequirementsOrder Information Cable Description Part Length Number006-1086473 Meter Index Index-2 Drive Module Site Preparation Guide Operating current E2400 10x 23 E3300 21 E4400 Index-4 Drive Module Site Preparation Guide Drive Module Site Preparation Guide Index-5 Index-6 Drive Module Site Preparation Guide