GENERAL MALFUNCTION

If the equipment malfunctions, this may be because an electrostatic discharge or AC line interference has corrupted the information in the equipment memory circuits. Therefore:

-disconnect the plug from the AC line supply

-after waiting at least three minutes, reconnect the plug to the AC line supply

-re-attempt to operate the equipment

ERROR MESSAGES

When the display indicates some error messages (e.g. ERROR **), unplug the power cable immediately. Contact your dealer, nearest Marantz distributor or the Marantz service center in your area.

Memory backup

nIn case a power outage occurs or the power cord is accidentally unplugged, the SR-19EX is equipped with a backup function to prevent memory data such as the preset memory from being erased.

The memory functions are backed up for up to about one week.

NOTE:

First of all keep SR-19EX Standby or Powered-on more than six hours, to sufficient time for memory back up.

HOW TO RESET THE UNIT

Should the operation or display seem to be abnormal, reset the unit with the following procedure.

The SR-19EX is turned on, press and hold the CL (CLEAR) o and DISPLAY OFF @0buttons simultaneously for 3 seconds or more. Remember that the procedure will reset the settings of the function selector, Surround mode, delay time, TUNER PRESET etc., to their initial settings.

40

Image 45
Contents Model SR-18EX User Guide AUX Input Video Video OUTVideo Audio OUT OUT OUT OUT OUT Digital Audio Video S-VIDEO Video CameraCenter Speaker CD Player Subwoofer Speaker System AmplifierOutput DigitalOther Connections Power AmprifirOther Multi Channel Processor MA700No USER-SERVICEABLE Parts Inside Refer Servicing to Qualified Service PersonnelDo not Remove Cover or Back AC Polarized Plug Read Before Operating EquipmentNEC Section @2@0 I !0 O !1!2!3 Table of Contents Description IntroductionFeatures Button Front Panel Features see8PRESET Button Display Rear Panel Connections AC Inlet AC OutletsRemote Control Unit RC-18SR ⁄1VOLUME UP + and Down⁄2TEN Keypad No Good Operation of Remote Control UnitOn Screen Display Menu System SetupSpeakers Setup Speakers Setup and Levels SetupSpkrs Setup 1/2 Speaker Size OSD Menu SystemLevels Setup 1/2 Test Tone Generator Spkrs Setup 2/2 Speaker DistanceLevels Setup 2/2 Bass Peak Level Limit L U M ES T E M S E T U P 2 System Setup 2/2 Assignable Digital InputA L O G P E A L O GGeneral Information On Screen Display InfomationListening to the Tuner Basic OperationPlayback Operation Station Name PresetDirect Frequency Call Normal PlaybackOther Functions Setting the Sleep Timer only Remote Control UnitMulti Room Selector TV Auto ON/OFF FunctionFunction and Operation OperationFunction ⁄3MEMO⁄4CLEAR ⁄7MUTE Liquid Crystal Display LCD Window⁄8GUIDE ⁄9LIGHTINGRC-18SR Basic Operation Programming the Direct mode buttons mHow to re-write the Direct function button names How to re-write the Status nameHow to clear erase the memorized codes Any re-written names Erasing the memory assigned to a particular buttonAdvanced Programming Techniques Macro modeErasing the memory assigned to a Direct buttons Complete erasureWould not normally be included in a macro sequence, and are Therefore not available for inclusion in a macroProgramming a macro under a function selector key Clone mode Using the macro functions you have programmedRC-18SR RC2000MKII ALL OK Table of cloning relationsVER Other FunctionsDirect Command Functions Listing DVD MODE1 Angl Tape Mode TP-BSubt MenuPIP2/REC VCR1 ModeRest SLPAUX VCD/PHI Mode ProgRest OSD VCD/PHI PBCSurround Modes DSP THX EXDigital Stereo Surround Mode CH status 5ch StereoDigital Mono 6ch InputSymptom Cause Remedy TroubleshootingMemory backup Error MessagesHOW to Reset the Unit General MalfunctionFM Tuner Section Technical SpecificationsAM Tuner Section Audio SectionIs a registered trademark