IPSO T45, T30 installation manual T438I

Page 16

Tumblers – T30 and T45

The vent collector system must be designed so the static back pressure measured 12 inches (305 mm) from the exhaust outlet does not exceed the maximum allowable pressure specified on the installation sticker on the rear of tumbler. Static back pressure must be measured with all tumblers vented into the collector operating.

NOTE: Never connect a tumbler duct at a 90° angle to the collector duct. Refer to Figure 3. Doing so will cause excessive back pressure, resulting in poor performance. Never connect two tumbler exhaust ducts directly across from each other at the point of entry to the collector duct.

With the tumbler in operation, and both pockets running, airflow at any point in the duct should be at least 1200 feet per minute (366 meters per meter) to ensure that lint remains airborne. If 1200 feet per minute cannot be maintained, schedule monthly inspections and cleaning of the ductwork.

T438I

Figure 3

15

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

4-08-43

Image 16
Contents On-Premise Laundry Planning Handbook Contents Introduction Model IdentificationTumblers T30 and T45 Conversion Table Multiply To ObtainSteam Coil Rating at 100 psig Boiler Horsepower Btu/hr Pounds kgCylinder Size Inches mmCabinet Dimensions Models T30Exhaust Outlet Locations Models Rear ExhaustGas Connection Locations Models Gas ConnectionElectrical Connection Locations Steam Connection Locations Models Inlet Outlet T30Upper LowerInstallation Pre-Installation InspectionW056R1 TMB2110N Exhaust Requirements LayoutMake-Up Air VentingIndividual Venting Duct Equivalent Length of Rigid Diameter Straight DuctManifold Venting T438I Duct T30 T45 Mm DuctDuct T30 T45 Station Mm Duct TWO Manifold AssembliesElectrical Requirements for Gas and Steam Models Terminal Block Recommended Fuse CurrentMinimum Connections Amps Or Breaker Rating Poles Conductor SizeElectrical Requirements for Electric Models Terminal Block RecommendedCurrent Breaker Minimum Connections Amps Poles Conductor Size Required