IPSO T30, T45 Pounds kg, Cylinder Size, Inches mm, Maximum Airflow per Pocket, M. l/sec

Page 5

 

 

 

 

 

Tumblers – T30 and T45

Specifications and Dimensions

 

 

 

 

 

 

 

 

 

 

Specifications

 

 

T30

T45

 

 

 

 

Noise level measured during operation at operator

 

66 dBA

67 dBA

position of 3.3 feet (1 meter) in front of machine and

 

 

 

5.2 feet (1.6 meters) from floor.

 

 

 

 

Net Weight (approximate):

 

 

544

673

Pounds (kg)

 

 

(247)

(305)

Cylinder Size:

 

 

30 x 26

33 x 30

Inches (mm)

 

 

(762 x 660)

(838 x 762)

Cylinder Capacity (dry weight)

 

 

2 x 30

2 x 45

Pounds (kg)

 

 

(2 x 13.6)

(2 x 20.5)

Drive Motor Horsepower**

 

 

1/4

1/2

 

 

 

 

 

Fan Motor Horsepower**

 

 

1/4

1/2

 

 

 

 

 

 

 

 

50 Hertz

 

340

N/A

Maximum Airflow per Pocket**:

 

 

 

(160)

 

C.F.M. (l/sec)

 

60 Hertz

 

400

600

 

 

 

 

(189)

(283)

 

 

 

 

 

 

 

 

50 Hertz

 

0.8

N/A

Maximum Static Back Pressure*:

 

 

 

(2.0)

 

Inches W.C. (mbar)

 

60 Hertz

 

0.9

0.9

 

 

 

 

(2.3)

(2.3)

 

 

Gas Models

 

 

 

 

 

 

 

Gas Connection

 

 

1/2 in. NPT

1/2 in. NPT

 

 

 

 

 

Gas Burner Rating**:

 

 

73,000

95,000

Btu/hr (kW, Mj/hr)

 

 

(21.4, 77)

(27.8, 100.2)

 

 

Electric Models

 

 

 

 

 

 

 

Heating Element Rating**:

 

 

21 kW

N/A

 

 

 

 

 

 

 

 

Steam Models

 

 

 

 

 

 

 

Steam Connection

 

 

3/4 in. NPT

N/A

 

 

 

 

 

Steam Coil Rating at 100 psig**:

 

 

3.2

N/A

Boiler Horsepower (Btu/hr)

 

 

(111,000)

 

(recommended operating pressure 80-100 psig)

 

 

 

*with both pockets running

**for each pocket

N/A = Not Applicable

4-08-43

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

4

Image 5
Contents On-Premise Laundry Planning Handbook Contents Model Identification IntroductionConversion Table Multiply To Obtain Tumblers T30 and T45Pounds kg Steam Coil Rating at 100 psig Boiler Horsepower Btu/hrCylinder Size Inches mmModels T30 Cabinet DimensionsModels Rear Exhaust Exhaust Outlet LocationsModels Gas Connection Gas Connection LocationsElectrical Connection Locations Models Inlet Outlet T30 Steam Connection LocationsUpper LowerPre-Installation Inspection InstallationW056R1 TMB2110N Layout Exhaust RequirementsMake-Up Air VentingDuct Equivalent Length of Rigid Diameter Straight Duct Individual VentingManifold Venting T438I Mm Duct Duct T30 T45TWO Manifold Assemblies Duct T30 T45 Station Mm DuctElectrical Requirements for Gas and Steam Models Current Terminal Block Recommended FuseMinimum Connections Amps Or Breaker Rating Poles Conductor SizeTerminal Block Recommended Electrical Requirements for Electric ModelsCurrent Breaker Minimum Connections Amps Poles Conductor Size Required