3.10 DRIVE BELT

The engine drives the generator rotor by means of a pulley and drive belt arrangement. Drive belt tension was properly adjusted before the unit was shipped from the factory. If suspect that drive belt tension is incorrect, contact an Authorized Service Dealer.

3.11 EXERCISING THE GENERATOR

The manufacturer recommends starting and operat- ing the generator at least once every seven days. Let the unit run for at least 30 minutes to “exercise” the engine.

3.12 OUT OF SERVICE PROCEDURE

‹3.12.1 REMOVAL FROM SERVICE

If the generator cannot be exercised every seven days, and it is to be out of service longer than 30 days, pre- pare the generator for storage as follows:

1.Start the engine and let it warm up.

2.Close the fuel shutoff valve in the fuel supply line and allow the unit to shut down.

3.While the engine is still warm from running, drain the oil completely. Refill the crankcase with SAE 5W-30 oil having API classification “For Service SF.”

4.Attach a tag to the engine indicating the viscosity and classification of the oil in the crankcase.

5.Remove the spark plug and pour two or three tablespoons of clean, fresh engine oil into the spark plug threaded openings. Reinstall and tighten the spark plug.

6.Remove the battery and store it in a cool, dry room on a wooden board. Never store the battery on any concrete or earthen floor.

7.Clean and wipe the entire generator.

To return the unit to service after storage, proceed as follows:

1.Check the tag on the engine for oil viscosity and classification. Verify that the correct recommend- ed oil is used in the engine (see Section 1.5.4). If necessary, drain and refill with the proper oil.

2.Check the state of the battery. Fill all cells of unsealed batteries to the proper level with dis- tilled water. DO NOT USE TAP WATER IN THE BATTERY. Recharge the battery to 100 percent state of charge, or, if defective, replace the battery.

3.Clean and wipe the entire generator.

4.Reconnect the battery. Observe battery polarity. Damage may occur if the battery is connected incorrectly.

5.Turn OFF all electrical loads. Add fuel if neces- sary and then start the engine.

6.Allow the unit to warm up thoroughly.

7.Apply electrical loads to at least 50 percent of the unit’s rated wattage capacity.

8.When the engine is thoroughly warmed up, shut it down.

9.The generator is now ready for service.

3.13 RV GENERATOR SERVICE INTERVAL

50 Hours

Clean Spark Arrestor

1st 50 Hours,

 

 

then every 500 Hours

............... Adjust Valve Lash

100 Hours

Change Engine Oil/Filter

100 Hours

Clean Air Pre-filter

100 Hours

Inspect Spark Plugs

250 Hours

Replace Paper Air Filter Element

400 Hours

Replace Fuel Filter

500 Hours

Replace Spark Plugs

15

Image 17
Contents This manual should remain with the unit ‹ Operation and Maintenance ‹ Contents‹ HOW to Obtain Service IntroductionPart I Operating Instructions Part II Installation Instructions Warning   Electrical Hazards   Reference Number Identification Generator IdentificationSafety InstallationGenerator Applicability Generator AC Connection System‹ 1.6.3 Engine Specifications Specifications‹ 1.6.2 Engine OIL Requirements ‹ 1.6.1 Fuel Requirements GasolineGenerator Control Panel ‹ 2.1.2 START/STOP Switch‹ 1.6.5 Emissions Compliance Period ‹ 2.1.1 Fuel PrimerAutomatic Choke Optional Remote START/STOP PanelBefore Starting the Engine ‹ 2.7.1 Letting the Engine Stabilize Starting the GeneratorStopping the Generator ‹ 2.8.2 High Temperature Switch ‹ 2.8.1 LOW OIL Pressure SwitchProtection Systems ‹ 2.7.2 do not Overload the Generator‹ 2.8.4 Overvoltage Protection Checking the Engine OIL Level‹ 2.8.6 25-HOUR CHECK-UP ‹ 2.8.5 25-HOUR BREAK-IN PeriodChanging the Engine OIL AND/OR OIL Filter Maintaining the Engine AIR Cleaner‹ 3.3.1 Cleaning the Foam Precleaner Checking the Engine Spark Plug Clean Spark ArrestorBattery Maintenance Cleaning the Generator‹ 3.8.1 Weekly ‹ 3.8.2 Every SIX MonthsRV Generator Service Interval OUT of Service ProcedureDrive Belt Exercising the GeneratorRecreational Vehicle Generators Part  General Hazards   Electrical Hazards  Standards Booklets Purpose and Scope Installation InstructionsEquipment Description Generator Engine Operating SpeedMajor Features ‹ 6.1.1 Generator Location Location and Support‹ 6.1.2 Generator Support ‹ 6.1.3 Suspended Mounting Generator Compartments‹ 6.2.1 Compartment Size ‹ 6.1.4 Generator RestraintTypical Compartment Construction ‹ 6.2.3 Sound Insulating Materials‹ 6.2.4 Acoustics Cooling and Ventilating AIR‹ 6.2.5 Compartment Floor Cutouts ‹ 6.3.1 Generator AirflowGasoline Fuel System ‹ 6.3.2 Testing the Installation‹ 6.5.1 LP Fuel Consumption LB./HOUR LP GAS Fuel System‹ 6.4.2 Generator Fuel Supply Line ‹ 6.5.4 Vapor Withdrawal ‹ 6.5.2 Parts not Included in Fuel System‹ 6.5.5 Primary Regulator ‹ 6.5.3 Some Important Considerations‹ 6.5.9 Leakage Tests Exhaust System‹ 6.5.7 Fuel Supply Lines ‹ 6.6.1 Mufflers and Spark Arrestors ‹ 6.6.2 Exhaust System SafetyElectrical Connections ‹ 6.7.5 Isolating Different Power Sources ‹ 6.7.2 Wiring‹ 6.7.1 Electrical Junction BOX ‹ 6.7.3 Generator AC ConnectionsBattery Installation 15 Transfer Switch Isolation Method Post Installation Tests Optional AccessoriesBefore Initial START-UP Initial StartInstallation Checklist Testing Under LoadProblem Cause Correction Troubleshooting GuideRecreational Vehicle Generators Battery Voltage 19 18 Part NO. QTY Description View a QTY 113 Screw Hhtt M6-1.0 X 16 YC 28,2 Circuit Breaker 3 X 15A 15B 3938 ASSEMBLY, Crankcase RV Exploded Views and Parts Lists CASTING, Twin Regulator Housing PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule Commercial Applications

004702-0, 004703-0, 004704-0, 004705-0, 004706-0, 004707-0 specifications

Guardian Technologies has established itself as a prominent leader in the realm of air purification with its innovative product line, specifically the models 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, and 004707-0. Each model combines cutting-edge technology with user-friendly features to ensure a cleaner and healthier indoor environment.

One of the standout features across these models is the use of True HEPA filtration. This technology efficiently captures 99.97% of airborne particles as small as 0.3 microns, including dust, pollen, pet dander, and smoke. This is essential for individuals with allergies or respiratory issues, providing peace of mind through cleaner air.

In addition to the HEPA filters, Guardian Technologies incorporates activated carbon filters in these models. This feature helps reduce unwanted odors from pets, cooking, and household chemicals, making the air in your home more pleasant. The combination of HEPA and activated carbon makes these models effective for comprehensive air purification.

These models also integrate smart technology, offering user-friendly controls that simplify operation. Many units are equipped with filter change indicators, ensuring users are alerted when it’s time to replace the filters. This promotes optimal air quality and prolongs the efficiency of the machines.

The Guardian Technologies models have a compact and modern design, allowing them to fit seamlessly into any home or office decor. Their lightweight design facilitates easy mobility, enabling users to place them in various locations as needed.

Energy efficiency is another significant characteristic featured in these air purifiers. Many of the models are ENERGY STAR certified, which means they meet strict energy efficiency guidelines set by the U.S. Environmental Protection Agency. This not only helps reduce electricity costs but also makes these purifiers an environmentally friendly choice.

Noise levels are kept to a minimum with these units, ensuring they operate quietly without disrupting daily activities such as work, sleep, or family time. This is particularly important in shared living spaces, where background noise can be a concern.

Overall, Guardian Technologies presents an impressive lineup of air purifiers through models 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, and 004707-0. Their combination of advanced filtration, smart technology, energy efficiency, and stylish design positions them as excellent options for anyone looking to improve their indoor air quality. Whether in a home or office, these models contribute significantly to a healthier living environment, making them a worthy investment for consumers seeking enhanced air purification solutions.