PROBLEM

CAUSE

CORRECTION

Engine is running, but no AC

1.

 

Circuit breaker is open.

1.

 

Reset circuit breaker.

output is available.

2.

 

Poor connection or defective cord set.

2.

 

Check and repair.

 

3.

 

Connected device is bad.

3.

 

Connect another device that is in good condition.

 

4.

 

Fault in generator.

4.

 

Contact Authorized Service Facility.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Engine runs good but

1.

 

Short circuit in a connected load.

1.

 

Disconnect shorted electrical load.

bogs down when loads are

2.

 

Generator is overloaded.

2.

See “Don’t Overload the Generator” .

connected.

3.

 

Engine speed is too slow.

3.

 

Contact Authorized Service Facility.

 

4.

 

Shorted generator circuit.

4.

 

Contact Authorized Service Facility.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Engine will not crank.

1.

 

10 amp fuse at rear of generator control panel

1.

 

Replace fuse with only an identical 10-amp

 

 

 

has melted open.

 

 

replacement fuse.

 

2.

 

Battery weak or dead.

2.

 

Recharge or replace battery.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Engine will not start; or

1.

 

Dirty air cleaner.

1.

 

Clean or replace air cleaner.

starts and runs rough.

2.

 

Out of gasoline.

2.

 

Fill fuel tank.

 

3.

 

Stale gasoline.

3.

 

Drain fuel tank and fill with fresh fuel.

 

4.

 

Spark plug wire not connected to spark plug.

4.

 

Connect wire to spark plug.

 

5.

 

Bad spark plug.

5.

 

Replace spark plug.

 

6.

Water in gasoline.

6.

 

Drain fuel tank; fill with fresh fuel.

 

7.

 

Overchoking.

7.

 

Put choke knob to No Choke position.

 

8.

 

Low oil level.

8.

 

Fill crankcase to proper level.

 

9.

 

Excessive rich fuel mixture.

9.

 

Contact Authorized Service Facility.

 

10.

Intake valve stuck open or closed.

10.

Contact Authorized Service Facility.

 

11.

Engine has lost compression.

11.

Contact Authorized Service Facility.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Engine shuts down during

1.

 

Out of gasoline.

1.

 

Fill fuel tank.

operation.

2.

 

Low oil level.

2.

 

Fill crankcase to proper level.

 

3.

 

Fault in engine.

3.

 

Contact Authorized Service Facility.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Engine lacks power.

1.

 

Load is too high.

1.

 

See “Don’t Overload the Generator”.

 

2.

 

Dirty air filter.

2.

 

Replace air filter.

 

3.

 

Engine needs to be serviced.

3.

 

Contact Authorized Service Facility.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Engine “hunts” or falters.

1.

 

Choke is opened too soon.

1.

 

Move choke to halfway position until engine runs

 

2.

 

Carburetor is running too rich or too lean.

 

 

smoothly.

 

 

 

 

2.

 

Contact Authorized Service Facility.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Battery Charge DC

1.

 

Battery posts are corroded.

1.

 

Clean battery posts.

output.

2.

 

Battery cable is bad.

2.

 

Replace cable.

 

3.

 

Battery is defective.

3.

 

Check battery condition; replace if defective.

 

4.

 

Receptacle is bad.

4.

 

Contact Authorized Service Facility.

 

 

 

 

 

 

 

18

Image 20
Contents Ultra Source Section Exploded Views and Parts Lists 11.111.2 11.3Never add fuel while unit is running IntroductionRead this Manual Thoroughly Important Safety Instructions  General Hazards  Electrical Hazards   Explosion Hazards  Fire Hazards  Standards IndexAssembly Accessory BOXUnpacking Assembling the Wheel KITBattery Connection Handle AssemblyKnow the Generator Fuel Tank Tank holds 16 U.S. gallons of fuel1 120 VAC, 20 AMP, Duplex Receptacle 2 120 VAC, 20 AMP, Gfci ReceptacleHOW to USE the Generator 5 12 Volt DC, 10 AMP ReceptacleGrounding the Generator 50 aWattage Reference Guide Connecting Electrical LoadsDON’T Overload the Generator Synthetic oil should only be used after first oil change Adding GasolineAdding Engine OIL To Start the Engine Stopping the EngineCharging a Battery Automatic Idle ControlInitial START-UP Sensing LOW OIL PressureMaintenance Schedule Product SpecificationsGenerator Specifications Engine SpecificationsGeneral Recommendations Replacing the Spark Plug Service AIR CleanerClean Spark Arrestor Screen To adjust valve clearance Install new valve cover gasket Re-attach the valve coverGeneral To check valve clearance Avoid spray from spark plug holes when cranking engine Store the unit in a clean, dry placeLong Term Storage Other Storage TipsTroubleshooting Guide Electrical Data Wiring Diagram Drawing No G0731 Electrical Data Handle, Frame & Wheel Kit Drawing No E0695-B QTY Description Control Panel Drawing No G0727-B SWITCH, Rocker -/0 Generator Drawing No G0742-A Exploded Views and Parts Lists Generator Drawing No G0742-A GT-760/990 Engine Drawing No E8589-W Part Sleeve Exploded Views and Parts Lists WINGNUT, Airbox MANUFACTURER’S Emission Control System Warranty Coverage Emission Control System Warranty Warranty Schedule