Section 4 — Troubleshooting
4.1 TROUBLESHOOTING GUIDE
PROBLEM | CAUSE | CORRECTION | ||||
Engine is running, but no AC | 1. |
| Circuit breaker is open. | 1. |
| Reset circuit breaker. |
output is available. | 2. |
| Poor connection or defective cord set. | 2. |
| Check and repair. |
| 3. |
| Connected device is bad. | 3. |
| Connect another device that is in good condition. |
| 4. |
| Fault in generator. | 4. |
| Contact Authorized Service Facility. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Engine runs good but | 1. |
| Short circuit in a connected load. | 1. |
| Disconnect shorted electrical load. |
bogs down when loads are | 2. |
| Generator is overloaded. | 2. | See “Don’t Overload the Generator” . | |
connected. | 3. |
| Engine speed is too slow. | 3. |
| Contact Authorized Service Facility. |
| 4. |
| Shorted generator circuit. | 4. |
| Contact Authorized Service Facility. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Engine will not crank. | 1. |
| 10 amp fuse at rear of generator control panel | 1. |
| Replace fuse with only an identical |
|
|
| has melted open. |
|
| replacement fuse. |
| 2. |
| Battery weak or dead. | 2. |
| Recharge or replace battery. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Engine will not start; or | 1. |
| Dirty air cleaner. | 1. |
| Clean or replace air cleaner. |
starts and runs rough. | 2. |
| Out of gasoline. | 2. |
| Fill fuel tank. |
| 3. |
| Stale gasoline. | 3. |
| Drain fuel tank and fill with fresh fuel. |
| 4. |
| Spark plug wire not connected to spark plug. | 4. |
| Connect wire to spark plug. |
| 5. |
| Bad spark plug. | 5. |
| Replace spark plug. |
| 6. | Water in gasoline. | 6. |
| Drain fuel tank; fill with fresh fuel. | |
| 7. |
| Overchoking. | 7. |
| Put choke knob to No Choke position. |
| 8. |
| Low oil level. | 8. |
| Fill crankcase to proper level. |
| 9. |
| Excessive rich fuel mixture. | 9. |
| Contact Authorized Service Facility. |
| 10. | Intake valve stuck open or closed. | 10. | Contact Authorized Service Facility. | ||
| 11. | Engine has lost compression. | 11. | Contact Authorized Service Facility. | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Engine shuts down during | 1. |
| Out of gasoline. | 1. |
| Fill fuel tank. |
operation. | 2. |
| Low oil level. | 2. |
| Fill crankcase to proper level. |
| 3. |
| Fault in engine. | 3. |
| Contact Authorized Service Facility. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Engine lacks power. | 1. |
| Load is too high. | 1. |
| See “Don’t Overload the Generator”. |
| 2. |
| Dirty air filter. | 2. |
| Replace air filter. |
| 3. |
| Engine needs to be serviced. | 3. |
| Contact Authorized Service Facility. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Engine “hunts” or falters. | 1. |
| Choke is opened too soon. | 1. |
| Move choke to halfway position until engine runs |
| 2. |
| Carburetor is running too rich or too lean. |
|
| smoothly. |
|
|
|
| 2. |
| Contact Authorized Service Facility. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
No Battery Charge DC | 1. |
| Battery posts are corroded. | 1. |
| Clean battery posts. |
output. | 2. |
| Battery cable is bad. | 2. |
| Replace cable. |
| 3. |
| Battery is defective. | 3. |
| Check battery condition; replace if defective. |
| 4. |
| Receptacle is bad. | 4. |
| Contact Authorized Service Facility. |
|
|
|
|
|
|
|
18