Greenheck Fan HRE-20, 90, 55, 45 Lubrication, Dampers, Fan Belts, Fan Motors, Fan Wheel & Fasteners

Page 36

routine maintenance

Lubrication

Check all moving components for proper lubrication.. Apply lubrication where required.. Any components showing excessive wear should be replaced to maintain the integrity of the unit and ensure proper operation..

Dampers

Check all dampers to ensure they open and close properly and without binding.. Backdraft dampers can be checked by hand to determine if blades open and close freely.. Apply power to motorized dampers to ensure the actuator opens and closes the damper as designed..

Fan Belts

Belts must be checked on a regular basis for wear, tension, alignment, and dirt accumulation.. Premature or frequent belt failures can be caused by improper belt tension (either too loose or too tight) or misaligned sheaves.. Abnormally high belt tension or drive misalignment will cause excessive bearing loads and may result in failure of the fan and/or motor bearings.. Conversely, loose belts will cause squealing on start-up, excessive belt flutter, slippage, and overheated sheaves.. Both loose and tight belts can cause fan vibration..

When replacing belts on multiple groove drives, all belts should be changed to provide uniform drive loading.. Do not pry belts on or off the sheave.. Loosen belt tension until belts can be removed by simply lifting the belts off the sheaves.. After replacing belts, insure that slack in each belt is on the same side of the drive.. Belt dressing should never be used..

Do not install new belts on worn sheaves.. If the sheaves have grooves worn in them, they must be replaced before new belts are installed..

Deflection = Belt Span 64

Belt Span

Proper fan belt settings

Fan Motors

The proper belt setting is the lowest tension at which the belts will not slip under peak load operation.. For initial tensioning, set the belt deflection at 1/64-inch for each inch of belt span (measured half-way between sheave centers).. For example, if the belt span is 64 inches, the belt deflection should be 1 inch (using moderate thumb pressure at mid-point of the drive).. Check belt tension two times during the first 24 hours of operation and periodically thereafter..

Motor maintenance is generally limited to cleaning and lubrication.. Cleaning should be limited to exterior surfaces only.. Removing dust and grease buildup on the motor housing assists proper motor cooling. Never wash-down motor with high pressure spray.. Greasing of motors is only intended when fittings are provided.. Many fractional motors are permanently lubricated for life and require no further lubrication..

Fan Wheel & Fasteners

Wheels require very little attention when moving clean air.. Occasionally oil and dust may accumulate on the wheel causing imbalance.. When this occurs the wheel and housing should be cleaned to assure smooth and safe operation.. Inspect fan impeller and housing for fatigue, corrosion or wear..

Routinely check all fasteners, set screws and locking collars on the fan, bearings, drive, motor base and accessories for tightness.. A proper maintenance program will help preserve the performance and reliability designed into the fan..

36

Image 36
Contents Read and Save These INSTRUCTIONS461248 Indirect Evaporative CoolerDirect Evaporative Cooler TABLE OF Contents StorageBasic Operation Installation Safety WarningLifting Roof Curb Mounting Rail Mounting Ductwork ConnectionsSupply Weatherhood Exhaust WeatherhoodElectrical Information TYPICAL CONTROL CENTER COMPONENTS Exploded Detail Terminal StripService Clearances / access panel locations HRE-20 HRE-45HRE-55 HRE-90 Dimensional Data / Access Door Descriptions Model Exterior Dimensions HRE-20Overall Exterior Dimensions Model Dimensional dataEvap Module Installation Standard Trap and Supply Line ConfigurationEvaporative Cooling Modules Evap Module START-UPWater Flow Adjustment DevicePump and Float Components HRE Water SUPPLY CONNECTION LocationTop View EvaporativeEvaporative FreezeTimer Protection Trap & Supply Line Configuration with Auto Drain and FillWater Control Options for Evaporative Cooling Auto Drain and Fill with Freeze ProtectionDrain Trap Drain and Overflow Connection Locations Troubleshooting for evaporative module Symptom SolutionEvaporative Cooling Maintenance Optional accessories Electric Heater Application/OperationElectric Preheater Post-Heater Control PanelFrost Threshold Temperatures TimerTesting Frost Control Application/OperationEconomizer Application/Operation Modulating the Wheel Enthalpy Sensor With OverrideVariable Frequency Drives for Blowers Yaskawa Yaskawa E7Variable Frequency Drives for Energy Recovery Wheel Factory Setpoints Modulating Control 0-10 VDC for FAN SpeedWiring Diagram TransformerRotation Sensor Dirty Filter SensorService Outlet CO2 SensorVapor Tight Lights Optional Accessories Remote Control Panel and Wiring SchematicsRemote Panel Wiring Schematics Indicator Lights powered by the ER UnitHeating/Cooling Switches and Night Setback Switch/Timer Temperature Sensors 1K Ohm RTD Sensors Mounted by FactoryStart-Up Checklist for unit Safety DangerSafety Caution Start-Up Checklist Start-Up Checklist for Evaporative CoolerSpecial Tools Required Optional Accessories Checklist Optional Accessories sectionEconomizer Application / Operation section Variable Frequency Drives sectionUnit start-up Fans Forward Curved TypeFan Performance Modifications Fan Belt DrivesDirection of Fan Wheel Rotation Fan RPMVibration Rotation DirectionDrive Belt Air SealsInside layout of HRE unit Routine maintenance DateLubrication DampersFan Belts Fan MotorsExternal Filter Maintenance Internal Filter MaintenanceDoor Seal Maintenance BearingsEnergy Recovery Wheel Maintenance Access to wheel through Outdoor air filter doorWheel segment removed Wheel Belt & Pulley Wheel BearingParts List Model HRESequence of Operation Basic UnitSummer Operation Winter OperationPressure Drop Across Energy Recovery Wheel Test and Balance ReportDesign Airflow Measured AirflowTroubleshooting Symptom Possible Cause Corrective ActionWarranty
Related manuals
Manual 24 pages 59.92 Kb

45, 55, 90, HRE-20 specifications

The Greenheck Fan HRE series, specifically the models HRE-20, HRE-90, HRE-55, and HRE-45, represents a blend of innovation and efficiency in the HVAC industry. Built for both commercial and industrial applications, these exhaust fans stand out due to their robust design and advanced operational features.

One of the main features of the HRE series is its energy-efficient motor design. These fans come equipped with a premium efficiency motor that reduces energy consumption while maintaining high performance. The motors are specifically designed to provide exceptional airflow while operating at lower sound levels, ensuring a quieter environment.

The HRE models also showcase advanced aerodynamic design, featuring optimized blade geometry that enhances airflow performance. This design ensures that the fans can deliver consistent and effective air movement even at varying operational conditions. This makes the HRE series suitable for use in a wide range of applications, from commercial kitchens to industrial processes.

Another significant characteristic of the HRE series is its durability. Constructed from high-quality materials, these fans are built to withstand harsh environmental conditions and prolonged usage. The robust casing and corrosion-resistant finishes ensure longevity, reducing the need for frequent repairs or replacements.

In terms of installation and maintenance, the HRE series offers significant advantages. The fans are designed for easy installation with clear mounting instructions. Additionally, maintenance procedures are simplified, allowing for hassle-free access to critical components, which reduces downtime and operating costs.

Technologically, the HRE models incorporate advanced controls and monitoring systems. These systems can offer real-time feedback on operational performance, allowing for proactive maintenance and energy management. Integrated controls can be customized to work with building management systems, providing users with seamless integration and control capabilities.

Overall, the Greenheck Fan HRE-20, HRE-90, HRE-55, and HRE-45 exemplify a commitment to quality and efficiency in commercial and industrial ventilation solutions. Their combination of energy efficiency, advanced design, durability, and user-friendly features make them a leading choice for those seeking reliable airflow solutions. These fans not only meet current industry standards but also set a benchmark for performance and innovation in the HVAC sector.