SYSTEM TROUBLE ERROR CODES

SYSTEM TROUBLE ERROR CODES

Your control panel is capable of detecting a variety of troubles that may affect system performance. In the unlikely event that a problem should occur, the SYS TBL (system trouble) icon will display on the left side of keypad window along with one or more of the following error codes. If the problem is related to a specific zone or device, the corresponding number will also be indicated. Below is a list of the most common troubles along with the necessary corrective action, if any. If a message appears that is not listed below, call your security professional for service. When a system trouble occurs, the keypad can be silenced and the display can be cleared by pressing C. The system can then be armed and disarmed as usual.

Note: If you cannot clear a system trouble yourself, call installing company for service as soon as possible.

Trouble

System Trouble

Action

Indication

Condition

 

 

 

 

E01-00

AC Power Failure

This trouble will occur if AC power is not present. Make sure system transformer is plugged into

 

 

AC receptacle and check the circuit breaker, otherwise call installing company for service.

 

Low Battery

If there has been a recent power failure, the battery may be partially depleted and must be

E02-00

 

recharged by the control panel. The control panel performs an automatic daily test of the

 

 

battery, at which time the trouble will clear if the battery has been recharged.

 

 

If the trouble does not clear in 24 hours, call installing company for service.

 

 

 

 

Communication

The system was not able to report to central station. If this is due to a temporary interruption in

E03-00

Failure

the telephone service, the trouble can be cleared when the service is restored by performing a

 

 

Communication Test:

 

 

1 While disarmed, enter your User Code followed by R.

 

 

2 Answer NO (Q) until “ACTIVATE DIALER TEST” appears in the window.

 

 

3 Press YES (P) to send a test signal to the central station.

 

 

If the trouble continues, call installing company for service.