GUARDIAN “EMERGENCY AUTOMATIC STANDBY GENERATORS”

For a period of two years from the date of original sale, Generac Power Systems, Inc. (Generac) will, at its option, repair or replace any part which, upon examination, inspection and testing by Generac or a Generac Authorized Warranty Service Dealer, is found to be defective under normal use and service, in accordance with the warranty schedule set forth below. Any equip- ment that the purchaser/owner claims to be defective must be returned to and examined by the nearest Generac Authorized Warranty Service Dealer. All transportation costs under the warranty, including return to the factory, are to be borne and pre- paid by the purchaser/owner. This warranty applies only to Generac emergency automatic standby generators sold and rated for use in "Standby" applications.

WARRANTY SCHEDULE

YEARS ONE and TWO - 100% (one hundred percent) transferable coverage on Labor and Part(s) listed (proof of purchase and maintenance is required):

Engine - All Components

Alternator - All Components

Transfer System - All Components

All warranty expense allowances are subject to the conditions defined in Generac's Warranty Policies, Procedures and Flat Rate Manual.

THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING:

Generac generators that utilize non-Generac replacement parts.

Generac/Guardian generators utilizing non-Generac/Guardian automatic transfer switches.

Any Generac generators used as rental or trailer mounted applications.

Units used for prime power in place of existing utility power where utility power is present or in place of utility power where utility power service does not normally exist.

Costs of normal maintenance, adjustments, installation and start-up.

Failures caused by any contaminated fuels, oils, coolants or lack of proper fluid amounts.

Failures due, but not limited, to normal wear and tear, accident, misuse, abuse, negligence or improper installation. As with all mechanical devices, the Generac engines need periodic part(s) service and replacement to perform well. This warranty will not cover repair when normal use has exhausted the life of a part(s) or engine.

Failures caused by any external cause or act of God, such as collision, theft, vandalism, riot or wars, nuclear holocaust, fire, freezing, lightning, earthquake, windstorm, hail, volcanic eruption, water or flood, tornado or hurricane.

Damage related to rodent infestation.

Products that are modified or altered in a manner not authorized by Generac in writing.

Any incidental, consequential or indirect damages caused by defects in materials or workmanship, or any delay in repair or replacement of the defective part(s).

Failure due to misapplication.

Telephone, cellular phone, facsimile, internet access or other communication expenses.

Living or travel expenses of person(s) performing service, except as specifically included within the terms of a specific unit warranty period.

Expenses related to "customer instruction" or troubleshooting where no manufacturing defect is found.

Rental equipment used while warranty repairs are being performed.

Overnight freight costs for replacement part(s).

Overtime labor.

Starting batteries, fuses, light bulbs and engine fluids.

USE OF NON-GENERAC/GUARDIAN TRANSFER SWITCHES SHALL VOID THIS WARRANTY WITH RESPECT TO ALL GENERAC PRODUCT.

THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. SPECIFICALLY, GENERAC MAKES NO OTHER WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

GENERAC'S ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT SHALL GENERAC BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC'S NEGLIGENCE. Some states do not allow the exclusion or limitation of incidental or conse- quential damages, so the above limitation may not apply to you.

This warranty gives you specific legal rights. You also have other rights from state to state.

GENERAC POWER SYSTEMS, INC.

P.O. BOX 297 • WHITEWATER, WI 53190

Part No. 0D8846

Revision H (08/07/03)

Printed in U.S.A.

Image 60
Contents Installation Introduction Authorized Dealer LocationPost Installation Start-up Adjustments MaintenanceTroubleshooting Introduction Inside Front CoverGeneral Hazards Electrical Hazards ‹ Standards IndexUNPACKING/INSPECTION Protection SystemsSystem SET LED Your Generator 7 kW, Single Cylinder GH-410 EngineSpecifications ‹ 1.5.1 Generator‹ 1.5.2 Engine Reconfiguring the Fuel System Fuel Requirements RecommendationsFuel Consumption 1 7 KW, 410CC EngineTransfer Switch LocationGenerator 2.1 7 kW, 12 kW and 15 kW UnitsBattery Installation BatteryCheck Transfer Switch Operation Before Initial START-UPElectrical Checks Generator Tests Under Load Checking Automatic OperationAdjusting the Regulator Natural GAS only Engine Governor Adjustment1 7 KW Units Voltage Regulator Adjustment 2 12 KW and 15 KW UnitsBREAK-IN Procedure Automatic Transfer Operation‹ 3.2.3 Manual Position ‹ 3.2.1 Auto PositionSequence of Automatic Operation Manual Transfer OperationSetting the Exercise Timer ‹ 3.5.2 Transfer Back to Utility Power Source‹ 3.7.1 LOW OIL Pressure Switch ‹ 3.7.2 High Temperature SwitchChecking the Engine OIL Level Approximate Crank Cycle Times‹ 3.7.4 Overspeed ‹ 4.3.2 OIL Change Procedure Changing the Engine OILChanging the OIL Filter ‹ 4.3.1 Engine OIL RecommendationsBattery Maintenance Spark PlugsAdjusting GH-410/GT-990 Valve Clearance Cooling SystemOUT of Service Procedure ‹ 4.12.1 Removal from Service‹ 4.12.2 Return to Service Corrosion ProtectionService Schedule SYSTEM/COMPONENT Procedure FrequencyTroubleshooting Guide Problem Cause CorrectionElectrical Data Customer Battery Utility Battery Charger Utility Connection BCR Customer Connections Neutral Exploded Views and Parts Lists Part NO.QTY. Description Exploded Views and Parts Lists QTY Description Exploded Views and Parts Lists BOX GTS Load Center Exploded Views and Parts Lists COVER, 12 Position GTS Load Center Kit Contains BUSHING, Governor Lower 138 122 KNOB, AIR Cleaner 28 31 ADAPTOR, Engine Exploded Views and Parts Lists Stator 12KW Exploded Views and Parts Lists ASSEMBLY, Connecting ROD Exploded Views and Parts Lists SCREW, Taptite M6-1.0X8 Yellow Chrome Engine only Mounting Dimensions Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule This Warranty Shall not Apply to the Following

04389-1, 04456-1, 04390-1 specifications

Generac Power Systems is synonymous with reliable and innovative power solutions for both residential and commercial applications. Among its diverse product lineup, the Generac 04390-1, 04456-1, and 04389-1 stand out due to their robust features, advanced technologies, and user-focused characteristics.

The Generac 04390-1 is a portable generator designed for versatility and efficiency. It is equipped with a powerful OHV engine that enables it to deliver up to 3500 running watts and 4375 starting watts, making it suitable for various applications, such as home backup during outages or powering tools on job sites. The generator features a built-in PowerRUSH technology, which provides a 40% more starting capacity than traditional models, allowing it to handle more demanding appliances and tools simultaneously. Additionally, its lightweight and compact design enhance portability, complemented by a sturdy handle and flat-free wheels.

Moving on to the Generac 04456-1, this model offers a greater output with 7500 running watts and 9400 starting watts. Ideal for larger homes or work environments, it is powered by a heavy-duty, 420cc engine and designed for optimal performance. The unit incorporates an electric start feature for easy operation and includes a low-oil shutdown system that protects the engine from damage, providing peace of mind to users. The reinforced roll-cage design ensures durability, while its quiet operation keeps noise levels to a minimum, making it suitable for more noise-sensitive environments.

Lastly, the Generac 04389-1 generator is particularly characterized by its dual-fuel capability, allowing users to run it on either gasoline or propane. This flexibility ensures seamless operation in various situations, with 5500 running watts on gasoline and 4950 running watts on propane. The model’s advanced engineering includes an easy-to-read fuel gauge, ensuring that users can monitor fuel levels without hassle. This generator is also equipped with a heavy-duty, full-wrap steel frame for resistance against impacts and wear, making it perfect for outdoor use.

Collectively, the Generac 04390-1, 04456-1, and 04389-1 models embody a commitment to quality and innovation. With their powerful engines, enhanced technologies, and user-friendly features, these generators provide peace of mind through reliable power solutions, catering to a multitude of needs for both residential and commercial users alike. Whether for emergency backup or regular use, Generac’s offerings ensure that power is always on hand when it’s needed the most.