OUTLET BOX
HANGER BRACKETBLACK SUPPLY WIRE
BLACK FAN WIRE
HANGER BRACKET | BLACK/WHITE RECEIVER WIRE | |
GROUND WIRE | ||
(GREEN) |
| |
| BLUE FAN WIRE | |
HANGER BALL | BLUE RECEIVER | |
GROUND WIRE | ||
(GREEN) | WIRE | |
| OPEN | |
| PORTION OF | |
| RECEIVER | |
SUPPLY GROUND | HERE | |
| ||
WIRE (GREEN OR | YELLOW FAN WIRE | |
BARE) | ||
| ||
RECEIVER | YELLOW RECEIVER WIRE | |
| ||
WHITE SUPPLY | BLACK RECEIVER WIRE | |
WIRE | WHITE RECEIVER WIRE | |
CEILING COVER | WHITE FAN WIRE | |
| WIRE CONNECTOR |
Figure 23
SW105 RECEIVER
BLACK SUPPLY
WIRE
WHITE RECEIVER WIRE
BLACK RECEIVER WIRE | WHITE SUPPLY WIRE |
BLACK/WHITE
RECEIVER WIRE BLUE RECEIVER WIRE
BLUE FAN WIRE
WHITE FAN WIRE
YELLOW RECEIVER WIRE
BLACK FAN WIRE
DOWNROD
Figure 24
WARNING
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.
4.After connections have been made, separate the white and green wires from the black, blue and yellow wires.
5.Carefully turn the wires upward and insert them up through the open side of the hanger bracket and into the outlet box. Push the green and white wires into one side of the outlet box; push the black, blue and yellow wires into the other side of the outlet box.
OUTLET BOX
HANGER
BRACKET
RECEIVER | |
STUDS (2) |
CEILING
COVER
Figure 25
Final Assembly
1.Screw the two
2.Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 26).
3.Secure the ceiling cover in place by installing two lockwashers and two knurled knobs (supplied) (Figure 26). Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod.
4.Your ceiling fan in now installed and wired and ready for use.
CEILING | ||
COVER | ||
THREADED | ||
STUD (2) |
| |
| LOCKWASHER (2) | |
| KNURLED KNOB (2) |
Figure 26
WARNING
To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.
10 | U.L. Model No.: CF3200 |