CONTROLS
Refueling
Propane Model
Read the safety instructions before refueling. The machine has two propane cylinder tanks, one on each side. Use only propane cylinders approved for this unit.
Regularly check the cylinders for damage and keep the valves properly tightened.
To exchange cylinders, turn the fuel valve clockwise to close. Remove the fuel line by turning the fitting clockwise (Left hand fitting).
Release the toggles holding the cylinders to the supports and lift the cylinders up off the alignment bolt and away from the unit.
IMPORTANT INFORMATION
Cylinders contain internal baffles and must be oriented properly. Use the alignment bolt on the cylinder support to seat the cylinder into the proper position.
Reverse procedure with full cylinders and tighten fuel line valve securely. Open fuel valve for operation.
WARNING!
The engine and the exhaust system, become very hot during operation.
Risk for burns if touched.
Allow engine and exhaust system to cool at least two (2) minutes before changing cylinder tanks.
WARNING!
Store propane cylinders away from open flames or where electrical arcing can occur. Do not tamper with the valves and fittings on the cylinder.
| 2 |
1 | 3 |
|
1.Toggles
2.Fuel Valve
3.Alignment Bolt
Set tank over alignment bolt
IMPORTANT INFORMATION
Propane fueled mowers draw from both tanks. It is recommended to keep at least ½ gallon of fuel in each tank when starting. During operation, the mower will draw and empty both tanks.
27