B&K 4070A manuals
Lawn and Garden > Portable Generator
When we buy new device such as B&K 4070A we often through away most of the documentation but the warranty.
Very often issues with B&K 4070A begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Portable Generator B&K 4070A is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Portable Generator on our side using links below.
88 pages 540.04 Kb
B&K Precision 3 Model 4070A Users Manual 4 Table of Contents 13 3.1 Mode key 3.2 Field arrow keys 3.3 Recall / Store key 3.4 Offset key 14 Offset voltage 3.5 Trigger key 3.6 Numeric keys (0 to 9, - and.) 3.7 , , , keys 15 3.8 Clear key 3.9 MHz/dBm, KHz/Vp-p/Sec, Hz/mVp-p/mS keys 3.10 One Touch Mode Keys 16 4.1 Changing frequency 4.2 Changing level 4.3 Changing operating modes 4.4 Operating mode selection. 17 4.5 Changing values 4.5.1 Modifying an existing value 18 5.0 Mode descriptions 5.1 Basic Sinewave (CW) Mode Sinewave ModeIntroduction Sinewave Mode Parameters 1. Frequency 2. Level Offset Ext Gating Input 1,000,000.00 Hz -10.0 dBm 19 5.2 Internal AM Mode Percent Mod: 100% Int AM: 1,000 HzInternal AM Mode Parameters 1. Modulating Frequency 2. Percentage modulation 3. Carrier Frequency 4. PEP Level Offset Ext Gating Input 1,000,000.00 Hz PEP level: -10.0 dBm 21 5.4 Internal FM Mode Pk dev: 10,000 Hz Int FM: 1,000 HzInternal FM Mode Parameters 1. Modulating Frequency 2. Peak Frequency Deviation 3. Carrier Frequency 4. Level Offset Ext Gating Input 1,000,000.00 Hz -10.0 dBm 23 5.6 Internal PM Mode Pk dev: 180 deg nt PM: 1,000 Hz IInternal PM Mode Parameters 1. Modulating Frequency 2. Peak Phase Deviation 3. Carrier Frequency 4. Level Offset Ext Gating Input 1,000,000.00 Hz -10.0 dBm 24 5.7 External PM Mode Pk dev: 180 deg External PMExternal PM Mode Parameters 1. Peak Phase Deviation 2. Carrier Frequency 3. Level Offset Ext Gating Input 1,000,000.00 Hz -10.0 dBm 25 5.8 Sweep Mode Stp: 20,000,000.00 Hz St: 1,000,000.00 Hz Sweep Mode Parameters 1. Start Frequency 2. Stop Frequency 3. Linear / Log sweep 4. Continuous / Triggered sweep Linear | Cont | Up | Time: 60,000 mS -10.0 dBm 27 5.9 Internal FSK Mode Mark: 1,000,000.00 Hz Int FSK: 1,000 HzInternal FSK Mode Parameters 1. Modulating Frequency 2. Mark Frequency 3. Space Frequency 4. Level Offset Ext Gating Input Space: 2,000,000.00 Hz -10.0 dBm 30 5.12 Internal SSB Mode Upper Sideband Int SSB: 1,000 HzInternal SSB Mode Parameters 1. Modulating Frequency 2. Upper/Lower Sideband selections 3. Carrier Frequency 4. Level Offset Ext Gating Input 1,000,000.00 Hz -10.0 dBm 32 5.16 DTMF Generation Mode Duration: 200 mS DTMF generation: #Background DTMF Generation Mode Parameters 1. Generated DTMF Digit Delay: 0 mS Level: -10.0 dBm 34 5.17 DTMF Detection Mode DTMF detection on Ext Mod input:*** Caution *** Background DTMF Detection Mode Parameters 1. DTMF detected digits 2. RS-232 Port 1 2 3 # A 4 35 5.18 Power & Voltage Measurement Mode dBm -- . -- + Measured Level on mod input: Power & Voltage Measurement Mode Parameters 1. Power Level 2. Voltage Level 3. System Impedance 4. External Modulation In Connector *** Caution*** 5. RS-232 Port Volts: + 003 mV Pwr res: 600 ohm 37 5.22 Internal BPSK Mode Int BPSK: 1,000 Hz 1,000,000.00 Hz - 10.0 dBm 38 5.23 External BPSK Mode External BPSKExternal BPSK Mode Parameters 1. Carrier Frequency 2. Level Offset Ext FSK Input 1,000,000.00 Hz - 10.0 dBm 39 5.24 Dualtone Generation Mode Dualtone F1: 10,000 Hz F2: 5,000 Hz : 0Dualtone Generation Mode Parameters 1. Tone 1 frequency 2. Tone 2 frequency 3. Phase Offset 4. Output On time 5. Output Off time 6. Level Offset Ton: 1,000 mS Toff: 0 mS -10.0 dBm 45 6.0 Remote Operation 51 7.0 Arbitrary Waveform Mode 63 E4 6 8Rules for Hexadecimal format: Example 7.8.6 Binary Format 64 E4 6 8
Also you can find more B&K manuals or manuals for other Lawn and Garden.