Carrier 58TMA manuals
Household Appliance > Furnace
When we buy new device such as Carrier 58TMA we often through away most of the documentation but the warranty.
Very often issues with Carrier 58TMA begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Furnace Carrier 58TMA is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Furnace on our side using links below.
Carrier 58TMA Operating Instructions
24 pages 331.84 Kb
Sizes 065-125, Series 111 amaFig. 1Dimensional Drawing 2 DE ATable 1Dimensions (In.) Fig. 2Clearances to Combustibles MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION 3 *1" # * *5 Fig. 3Confined Space: Air for Combustion and Ventilation from an Unconfined SpaceFig. 4Confined Space: Air for Combustion and Ventilation from Outdoors 6 Table 2Free Area Of Combustion Air OpeningFig. 5Floor and Plenum Opening Dimensions Table 3Opening Dimensions (In.) 7 Fig. 6Furnace, Plenum, and Subbase Installed on Combustible FloorFig. 7Furnace, Plenum, and Coil Assembly or Coil Box Installed on Combustible Floor 8 Fig. 9Horizontal Crawlspace Installation on Hanger RodsFig. 8Typical Attic Installation Fig. 10Horizontal Installation on Blocks 9 DFig. 12Downflow Filter Arrangement Fig. 11Horizontal Filter Arrangement Table 4Filter Retainer (In.) Table 5Maximum Capacity of Pipe* 10 Fig. 13Typical Gas Pipe ArrangementFig. 14Control Center 11 Table 6Electrical DataFig. 15Heating and Cooling Application Wiring Diagram With 1-Stage Thermostat and Condensing Unit Table 7Setup Switch Description 12 Fig. 16Heating and Cooling Application Diagram With 2-Stage Thermostat and Condensing UnitTable 8Blower Off Delay Setup Switch Position Fig. 17Setup Switches on Control Center (Factory Settings) 13 Fig. 18Unit Wiring DiagramA9750815.Spare terminal and wire not available on some 14.NA - Not Applicable unsuccessful trials-for-ignition. Control will automatically 10.BLOWER-ON DELAY: Gas heating 45 seconds, 9. Symbols are an electrical representation only. C turned ON. TO 115VAC FIELD DISCONNECT SWITCH CONNECTION DIAGRAM6. Auxiliary limit switches (ALS1 & 2) used on some horizontal and 2. If any of the original wire, as supplied, must be replaced, use the 1. Use only copper wire between the disconnect switch and the unit. NOTES: LEGEND - 1 = VALVE -324459-101 REV. A same or equivalent type wire. 3. Inducer (IDM) and blower (BLWM) motors contain internal auto-reset thermal overload switches. 4. Blower motor speed selections are for average conditions. See Installation Instructions for details on optimum speed selection. 5. Replace only with a 3-AMP fuse. some downflow models. 7. This wire must be connected to furnace sheet metal for control to prove flame. 8. Factory connected when LGPS not used. 2-STAGE FURNACE CONTROL SCHEMATIC DIAGRAM (NATURAL GAS & PROPANE) COMPONENT TEST CCooling/Heat Pump 2 seconds. 11.Cooling/Heat Pump BLOWER-OFF DELAY is 90 seconds. 12.IGNITION-LOCKOUT will occur after four consecutive reset after three hours. 13.Control must be grounded at pin 10 of 12-pin connector. applications. Insulate connector if not available. 17 Table 9Altitude Derate Multiplier for U.S.A.21 Table 11Gas Rate (Cu Ft/Hr)Fig. 19Redundant Automatic Gas Control Valve Fig. 20Burner Flame ON/OFF SWITCH INLET PRESSURE TAP MANIFOLD PRESSURE TAP LOW-FIRE ADJUSTMENT ALLEN SCREW (UNDER CAP) HIGH-FIRE ADJUSTMENT ALLEN SCREW (UNDER CAP) BURNER FLAME BURNER MANIFOLD 22 Table 12Speed SelectionFig. 21Amp Draw Check With Ammeter 24 SERVICE TRAINING
Also you can find more Carrier manuals or manuals for other Household Appliance.