Goodman Mfg ASPF Air Handlers manuals
Personal Care > Wheelchair
When we buy new device such as Goodman Mfg ASPF Air Handlers we often through away most of the documentation but the warranty.
Very often issues with Goodman Mfg ASPF Air Handlers begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Wheelchair Goodman Mfg ASPF Air Handlers is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Wheelchair on our side using links below.
Goodman Mfg ASPF Air Handlers Operating Instructions
16 pages 268.17 Kb
ASPFAIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION. ATTENTION INSTALLING PERSONNEL2 Important Safety InstructionsImportant Note to the Owner regarding Product Warranty 3 Shipping InspectionCodes & Regulations Replacement Parts Pre-Installation Instructions Location Ductwork 4 Electric Heat356810152021 CFM HEAT KIT NOMINAL kW 356810152021 CFM HEAT KIT NOMINAL kW HKR Installation Electrical Supply Wire and MOP5 HIGH VOLTAG E!Maximum Allowable Length in Feet to Limit Voltage Drop to 2%* Refrigerant LinesQuench all welded joints with water or a wet rag. For the correct tubing size, follow the specification for the condenser/heat pump. 6 CAUTION7 Downflow ConversionHorizontal ConversionASPF Model Insulation Kit 1830 DPIH36-42 3137 / 4260 DPIH48-61 Condensate Removal 8 CAUTIONIf secondary drain is not installed, the secondary access must be plugged. 9 Achieve 2% Low Leakage RateASPF Motor Start-Up Procedure Regular Maintenance ASPF Thermostat Connections 10 WARNINGCOOLING UNIT WITH OPTIONAL HEAT KITS OF 10 kW AND BELOW COOLING UNIT WITH OPTIONAL HEAT KITS OF 15 kW AND ABOVE AND ROOM THERMOSTAT WITH TWO STAGES OF HEAT 11 HEAT PUMP UNIT WITH OPTIONAL HEAT KITS OF 10 kW AND BELOW13 ASPF Wiring DiagramR 5 4 52 1 3 MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. 0140A00040-DPLM 6789 TR ONE (1) ELEMENT ROWS TWO (2) ELEMENT ROWS THREE (3) ELEMENT ROWS FOUR (4) ELEMENT ROWS COPPER POWER SUPPLY (USE RATING PLATE) USE MIN. 75 C FIELD WIREPLF 1 23 4 5 GRD 1234 5 678 9 21 43 5 NCGL LGN 3 1 2 4 W2RW1CG 4Y1 OY2 1DH 32 5 15 SPLIT SYSTEMSReplace or Clean Filter Compressor Motors Clean Outside Coil (Qualified Servicer Only) BEFORE CALLING YOUR SERVICER
Also you can find more Goodman Mfg manuals or manuals for other Personal Care.