Polaris PG10* 50-130-2NV OR 2PV manuals
Household Appliance > Water Heater
When we buy new device such as Polaris PG10* 50-130-2NV OR 2PV we often through away most of the documentation but the warranty.
Very often issues with Polaris PG10* 50-130-2NV OR 2PV begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Water Heater Polaris PG10* 50-130-2NV OR 2PV is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Water Heater on our side using links below.
Polaris PG10* 50-130-2NV OR 2PV Installation Instructions
32 pages 5.13 Mb
Polaris Residential Gas Water Heater Installation Instructions and Use & Care Guide2 Your safety and the safety of others are very important.Important Instructions T able of Contents 3 INSTALLATION INSTRUCTIONSConsumer Information Installer and Owner Responsibilities Unpacking the Water HeaterRemoving Packaging Materials 4 Location RequirementsFigure 1: Garage Installation FIRE AND EXPLOSION HAZARDCan result in serious injury or death Site Location 5 CONDENSATE LINEFigure 2: Minimum Clearance Locations Condensate Trap AssemblyFigure 3A: 2 Condensation Trap Installation 100,000 - 150,000 BTU/Hr Models Clearances and AccessibilityFigure 3B: 3 Condensation Trap Installation 175,000 - 199,000(50 gal.) BTU/Hr Models Figure 3C: 3 Condensation Trap Installation 100 Gallon Models Condensate Drain Line 6 VENT PIPE SYSTEMFigure 4: Condensate Drain Venting 7 Vent Pipe MaterialFigure 5: Correct and Incorrect Pipe Fittings Vent Pipe Installation Vent Pipe Length 8 Vent Termination LocationsFigure 6: Minimum Clearances for Inlet/Outlet and Concentric Vent 9 INLET/OUTLET VENT TERMINATIONS (100,000 - 150,000 BTU/HR)Standard Horizontal Termination Alternative Horizontal TerminationFigure 7A: Standard Horizontal Termination (100,000 - 150,000 BTU/Hr Models) Figure 8A: Alternate Horizontal Termination (100,000 - 150,000 BTU/Hr Input Models) 10 VERTICAL TERMINATIONS (100,000 - 150,000 BTU/HR)Figure 9A: Vertical Termination (100,000 - 150,000 BTU/Hr Models) Venting Additional Polaris Units (100,000 - 150,000 BTU/hr Models) 11 CONCENTRIC VENT TERMINATIONS (100,000 - 150,000 BTU/HR)12 INLET/OUTLET VENT TERMINATIONS (175,000+ BTU/HR)Figure 8B: Alternative Horizontal Termination (175,000+ BTU/Hr or greater input models) Figure 7B: Standard Horizontal Termination (175,000+ BTU/Hr models) Standard Horizontal Termination Alternative Horizontal Termination 13 VERTICAL TERMINATIONS (175,000+ BTU/HR)Figure 9B: Vertical Termination (175,000+ BTU/Hr models) Venting Additional Polaris Units (175,000+ BTU/Hr Models) 14 CONCENTRIC VENT TERMINATIONS (175,000 + BTU/HR)Concentric Venting Multiple Water Heaters (All Models) Gas Input Rate 15 WATER PIPING SYSTEMPiping Installation Corrosion and Water QualityFigure 15: Typical One-Temperature System Piping Installation 16 Tempering Valve InstallationGeneral Information Closed System/Thermal Expansion Combination Space Heating/Potable Water System 17 Storage Tank Installation Solar InstallationFigure 17: Air Handler Piping Installation 18 Temperature and Pressure Relief Valve19 GAS SUPPLY AND PIPING21 ELECTRICAL CONNECTIONSFigure 20B: Electrical Connections (100 Gal.) Figure 20A: Electrical Connections (34/50 Gal.) Note: 22 WIRING DIAGRAMMODELS 130,000 BTU/Hr & Below MODELS 150,000 BTU/Hr & AboveGAS VALVE THERMOSTAT BOARD IGNITION CONTROL 120 VAC 24 VACGAS VALVE RELAY THERMOSTAT SENSOR-ECO GV THERMOSTAT DIAL TO 120/60 POWER SUPPLYSEN-1 LOWER FUSED DISCONNECT L1 NEUTRALPSI THERMOSTAT DIALIGNITER IGNITION CONTROL 120V/60Hz BLOWERTHERMOSTAT BOARDNEUTRAL (WHITE) L1 (BLACK) FUSED DISCONNECTED TO 120/60 POWER SUPPLY 120 VAC (BLACK & WHITE WIRES IN BOLD) 23 INSTALLATION CHECKLIST Water Heater Location RequirementsCondensate Line Vent Pipe System V ent T ermination Water System Piping Gas Supply and Piping Electrical Connections 24 OPERATING YOUR WATER HEATERL.P. (Propane) Models Water Heater OperationFigure 21: Sequence of Operation Thermostat Sensor 25 StackingWater Temperature RegulationFigure 22: Temperature Dial Emergency Shut Down 26 OPERATIONAL CONDITIONSFigure 23: Hand Hole Clean-out MAINTENANCEFigure 24 Water Heater Sounds Safety Shut-Off (Pressure Switch) Energy Cut-Off (ECO) Draining and Flushing Temperature and Pressure Relief Valve 27 MAINTENANCE OF YOUR WATER HEATER 3 Month InspectionGas Valve Removing the Gas Valve Replacing the Gas Valve 28 TROUBLESHOOTING Ignition Control Module (ICM) LED Error Codes: (Flashes visible through viewport in access door) 30 REPAIR PARTS LIST/DIAGRAMTOOLS REQUIRED FOR SERVICING Repair Parts ListALL MODELS EXCEPT 100 GALLON 31 REPAIR PARTS LIST/DIAGRAM100 GALLON MODELSTOOLS REQUIRED FOR SERVICING Repair Parts List 32 POLARIS MODELS & DIMENSIONS34/50 Gallon Units 100 Gallon Units
Also you can find more Polaris manuals or manuals for other Household Appliance.