Polaris PR 199-50 3NV OR 3PV INLET/OUTLET VENT TERMINATIONS 175,000+ BTU/HR, Gallon Model Shown

Models: PG10* 50-175-3NV OR 3PV PR 199-50 3NV OR 3PV PG10* 34-150-2NV OR 2PV PR 100-34 2NV OR 2PV PG10* 100-199-3NV OR 3PV PG10* 34-100-2NV OR 2PV PR 130-50 2NV OR 2PV PR 130-34 2NV OR 2PV PG10* 34-130-2NV OR 2PV PG10* 50-130-2NV OR 2PV PR 175-50 3NV OR 3PV PR 150-34 2NV OR 2PV PG10* 50-199-3NV OR 3PV PR 199-100-3NV OR 3PV

1 32
Download 32 pages 63.46 Kb
Page 12
Image 12
INLET/OUTLET VENT TERMINATIONS (175,000+ BTU/HR)

INLET/OUTLET VENT TERMINATIONS (175,000+ BTU/HR)

Standard Horizontal Termination

The standard horizontal air inlet termination is a 3 inch pipe which terminates at the exterior wall and utilizes a coupling to prevent the pipe from being pushed back into the structure. The standard horizontal exhaust outlet termi- nation is a 3 inch pipe which terminates 12 inches from the outside wall. The air inlet must be located with respect to the exhaust outlet as shown in figure 7B (bottom).

Install a 3 inch coupling at the outside wall on both the inlet and exhaust to prevent the terminations from being pushed inward.

Install a drain tee assembly and trap in the inlet vent as close to the water heater as possible. This is to drain any water that may be in the combustion air pipe and prevent it from entering the blower. Connect the trap drain line to a suitable drain or downstream of the condensate trap of the water heater.

Note: See “Venting Additional Polaris® Units” on Page 13 for correct terminations if installing more than one Polaris® gas water heater.

Alternative Horizontal Termination

The combustion air and exhaust terminations may be raised up to 24 inches above the wall penetrations if required for anticipated snow levels (see figure 8B). The two elbows shown in figure 8B are considered part of the termination and should not be included when determining the maximum allowable vent pipe length.

Note: See “Venting Additional Polaris® Units” on Page 13 for correct terminations if installing more than one Polaris® gas water heater.

Figure 8B: Alternative Horizontal Termination (175,000+ BTU/Hr or greater input models)

Figure 7B: Standard Horizontal Termination (175,000+ BTU/Hr models)

*100 Gallon Model Shown.

12

Page 12
Image 12
Polaris PR 199-50 3NV OR 3PV INLET/OUTLET VENT TERMINATIONS 175,000+ BTU/HR, Standard Horizontal Termination