York D2EG 060 manuals
Household Appliance > Air Conditioner
When we buy new device such as York D2EG 060 we often through away most of the documentation but the warranty.
Very often issues with York D2EG 060 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Air Conditioner York D2EG 060 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Air Conditioner on our side using links below.
York D2EG 060 Installation Instructions
20 pages 765.22 Kb
SUNLINE PLUS GAS / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS INST ALLATION INSTRUCTION 2 TABLE OF CONTENTSINSTALLATION OPERATION START-UP MAINTENANCE & TROUBLESHOOTING TABLES FIGURES LIMITATIONS LOCATION FIG. 1 - CENTER OF GRAVITY RIGGING AND HANDLING CLEARANCES DUCTWORK 3 INSTALLATIONTABLE 1 - UNIT APPLICATION DATA FILTERS CONDENSATE DRAIN TABLE 2 - GAS HEAT APPLICATION DATA SERVICE ACCESS 4 THERMOSTAT POWER AND CONTROL WIRING BLOWER SPEED SELECTION COMPRESSORS COMBUSTION DISCHARGE FIG. 2 - RECOMMENDED DRAIN PIPING 5 DISCONNECT SWITCH BRACKET FOR UNITS WITH OPTIONAL BELT-DRIVE BRACKETTABLE 3 - PIPE SIZING GAS PIPING FIG. 3 - TYPICAL FIELD WIRINGUnitary Products Group 5 Length in Feet Nominal Iron Pipe Size 1/2 in. 3/4 in. 1 in. 1-1/4 in.CONTROL WIRING COOLING / HEATING (24 VOLT THERMOSTAT)T E R M I N A L S U N I T T E R M I N A L S T R I P T B 1 2 4 V O L T T R A N S F O R M E R COOLING / HEATING (ELECTRONIC THERMOSTAT) 2 3 6 GAS CONNECTIONL.P./PROPANE UNITS, TANKS AND PIPING LOW NOx APPLICATION FIG. 4 - EXTERNAL SUPPLY CONNECTION EXTERNAL SHUT-OFF FIG. 5 - BOTTOM SUPPLY CONNECTION EXTERNAL SHUT-OFF VENT AND COMBUSTION AIR HOODS OPTIONAL ECONOMIZER RAIN HOOD FIG. 7 - ECONOMIZER RAIN HOOD ASSEMBLY (OPTION) 7 13 OPERATIONSAFETY CONTROLS (Heating) HEAT ANTICIPATOR SETPOINTS FIG. 11 - GAS VALVES PRE-START CHECK LIST TABLE 12 - LIMIT CONTROL SETTING OPERATING INSTRUCTIONS POST-START CHECK LIST (GAS) MANIFOLD GAS PRESSURE ADJUSTMENT 14 START-UP15 PILOT CHECKOUTBURNER INSTRUCTIONS FIG. 14 - BELT ADJUSTMENT FIG. 13 - TYPICAL FLAME APPEARANCE BURNER AIR SHUTTER ADJUSTMENT SUPPLY AIR AIR BLOWER AND TEMPERATURE RISE ADJUSTMENTS FIG. 12 - PROPER FLAME ADJUSTMENT TABLE 13 - BELT-DRIVE SUPPLY AIR 16 CHECKING GAS INPUTTABLE 14 - GAS RATE - CUBIC FEET PER HOUR FIG. 15 - PRESSURE DROP ACROSS A DRY EVAPORATOR COIL VS SUPPLY AIR CFM, WITHOUT AIR FILTERS 17 MAINTENANCENORMAL MAINTENANCE CLEANING FLUE PASSAGES AND HEATING ELEMENTS 18 TROUBLESHOOTING19 TROUBLESHOOTING - Continued.
Also you can find more York manuals or manuals for other Household Appliance.