Manuals
/
Brands
/
Household Appliance
/
Furnace
/
Johnson Controls
/
Household Appliance
/
Furnace
Johnson Controls
CP8C/CPLC*MP, LP8C/LPLC*MP, TP8C/TPLC*MP, YP8C/YPLC*MP installation manual
Please, tick the box below to download manual:
Contents
Main
368262-UIM-B-1008
RESIDENTIAL GAS FURNACE WITH ECM MOTOR
INSTALLATION MANUAL
LIST OF SECTIONS
LIST OF FIGURES
LIST OF TABLES
SECTION I: SAFETY
368262-UIM-B-1008
SPECIFIC SAFETY RULES AND PRECAUTIONS
SAFETY REQUIREMENTS
368262-UIM-B-1008
Johnson Controls Unitary Products 3
COMBUSTION AIR QUALITY (LIST OF CONTAMINANTS)
CODES AND STANDARDS
INSPECTION
FURNACE LOCATION AND CLEARANCES
FOR FURNACES INSTALLED IN THE COMMON- WEALTH OF MASSACHUSETTS ONLY
Johnson Controls Unitary Products 5
SECTION II: DUCTWORK
DUCTWORK GENERAL INFORMATION
DUCT FLANGES
DUCTWORK INSTALLATION AND SUPPLY PLENUM CONNECTION - UPFLOW/HORIZONTAL
FLOOR BASE AND DUCTWORK INSTALLATION - DOWNFLOW
368262-UIM-B-1008
DOWNFLOW DUCT CONNECTORS
HORIZONTAL APPLICATION
RESIDENTIAL AND MODULAR HOME UPFLOW RETURN PLENUM CONNECTION
BOTTOM RETURN AND ATTIC INSTALLATIONS
Johnson Controls Unitary Products 7
DOWNFLOW APPLICATION
LEFT SIDE VENT RIGHT SIDE VENT
COIL INSTALLATION COIL/FURNACE ASSEMBLY - MC/FC/PC SERIES COILS
368262-UIM-B-1008
FURNACE ASSEMBLY - MC & FC SERIES COILS
Gas Furnace
Air flow
Mounting Plate
SECTION III: FILTERS
FILTER INSTALLATION
SIDE RETURN
LEFT SIDE RIGHT SIDE
SUPPLYEND
SECTION IV: GAS PIPING
GAS PIPING INSTALLATION
Inlet Pressure Tap
Outlet Pressure Tap
On/Off Knob
SECTION V: ELECTRICAL POWER
ELECTRICAL POWER CONNECTIONS
12 Johnson Controls Unitary Products
SUPPLY VOLTAGE CONNECTIONS
LOW VOLTAGE CONTROL WIRING CONNECTIONS
AIR CONDITIONER CONNECTIONS
*PP11C70224
AIR CONDITIONER
*PP32U70124
*DN22U00124
FIGURE 20: Thermostat Chart - Two Stage Air Conditioner Variable Speed or PSC Modulating Furnace
*PP11C70224
*DP32H70124
N/A
FIGURE 22: Thermostat Chart - Single Stage Heat Pump Variable Speed or PSC Modulating Furnace
*BP21H50124 *BN21H00124 *DP21H40124 *DN21H00124
*DN22U00124
FIGURE 23: Thermostat Chart - Single Stage Heat Pump Variable Speed or PSC Modulating Furnace
*DP32H70124
*BP21H50124 *BN21H00124 *DP21H40124 *DN21H00124
*DN22U00124
SINGLE STAGE HEAT PUMP
FIGURE 24: Thermostat Chart - Two Stage Heat Pump Variable Speed or PSC Modulating Furnace
HEAT PUMP
OD MODELS
*PP32U70124
*DN22H00124 *DP22U70124
SECTION VI: VENT SYSTEM
VENT CONNECTIONS
CATEGORY 1 - 450 F. MAX. VENT TEMP.
VENTING
VENTING INTO AN EXISTING CHIMNEY
20 Johnson Controls Unitary Products
FAN-ASSISTED COMBUSTION SYSTEM
Ambient Combustion Air Supply
Combustion Air Source From Outdoors
Dampers, Louvers and Grilles (Canada Only)
Johnson Controls Unitary Products 21
Air Supply Openings and Ducts
Combustion Air Source from Outdoors
Ventilated Combustion Air
Vent and Supply (Outside) Air Safety Check Procedure
SECTION VII: START-UP AND ADJUSTMENTS
NOx SCREEN REMOVAL (Lo-NOx Models Only)
GAS PIPING LEAK CHECK
Johnson Controls Unitary Products 23
SETUP TEST MODE
CALCULATING THE FURNACE INPUT (NATURAL GAS)
HIGH ALTITUDE NATURAL GAS ORIFICE CONVERSION
Page
Johnson Controls Unitary Products 25
ADJUSTMENT OF MANIFOLD GAS PRESSURE
Turn gas off at the ball valve or gas cock on gas supply line before the gas valve.
ADJUSTMENT OF TEMPERATURE RISE
368262-UIM-B-1008
26 Johnson Controls Unitary Products
ADJUSTMENT OF FAN CONTROL SETTINGS
Page
28 Johnson Controls Unitary Products
Delay Taps Selection
Humidistat
SECTION VIII: SAFETY CONTROLS
CONTROL CIRCUIT FUSE
BLOWER DOOR SAFETY SWITCH
ROLLOUT SWITCH CONTROLS
PRESSURE CONTROLS
SECTION IX: NORMAL OPERATION AND DIAGNOSTICS
NORMAL OPERATION SEQUENCE
FURNACE CONTROL DIAGNOSTICS
30 Johnson Controls Unitary Products
DIAGNOSTIC FAULT CODE STORAGE AND RETRIEVAL
SECTION X: REPLACEMENT PARTS LIST
REPLACEMENT PART CONTACT INFORMATION