Johnson Controls TP8C/TPLC*MP, YP8C/YPLC*MP, LP8C/LPLC*MP Adjustment of FAN Control Settings, Eac

Models: YP8C/YPLC*MP TP8C/TPLC*MP LP8C/LPLC*MP CP8C/CPLC*MP

1 32
Download 32 pages 6.92 Kb
Page 26
Image 26

368262-UIM-B-1008

ADJUSTMENT OF FAN CONTROL SETTINGS

Cooling - The airflow delivered by the furnace during cooling operation can be adjusted to match the cooling capacity of the A/C condensing unit. This is done by moving the COOL and ADJ jumper on the control board to give the desired airflow.

The COOL jumper has four positions, which will deliver sufficient airflow in cooling mode for the cooling capacities shown in Table 13.

the ADJ jumper has three positions which can be used to make further adjustments to the cooling blower airflow.

Continuous Fan Operation - The airflow delivered by the furnace dur- ing continuous fan operation can be adjusted as desired. This is done my moving the control fan jumper on the control board to give the desired airflow.

The jumper has three positions. The "H" position delivers maximum air- flow, 100% of the blower capacity. Position "M" delivers approximately 70% of the blower capacity. And Position "L" delivers minimum airflow, approximately 40% of the blower capacity.

Humidifier

EAC

Terminals

Terminals

 

Zoning

Jumper

Heat Pump

Jumper

Cooling

Speed

Jumper

Humidistat

Jumper

Continuous

Fan Speed

Jumper

Test

Button

Diagnostic

Low

Last

Voltage

Error

Light

Terminals

Button

 

FIGURE 29: Furnace Control Board

26

Johnson Controls Unitary Products

Page 26
Image 26
Johnson Controls TP8C/TPLC*MP, YP8C/YPLC*MP, LP8C/LPLC*MP, CP8C/CPLC*MP Adjustment of FAN Control Settings, Eac