368262-UIM-B-1008

LEFT SIDE

Vent Connection

 

 

Outlet

Electrical

Entry

Gas Pipe

Entry

Thermostat

Wiring

28.5”

29.5”

(For Cladded door add appoximately an additional .75”)

FRONT

Electrical

Entry

Vent

Connection

Outlet

Gas Pipe

Entry

33”

Thermostat

Wiring

A

RIGHT SIDE

23”

14”

1.5” 1”

.5” 24.38”

B

.5” 20”

4” Diameter

Vent Connection.5”

Outlet

B

C

24.25”

.5”

 

SUPPLY END

 

 

 

 

 

 

 

RETURN END

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 14: Dimensions

 

 

 

 

 

 

 

 

 

Table 3: Cabinet and Duct Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BTUH (kW)

 

Nominal

 

Cabinet

 

Cabinet Dimensions (Inches)

 

 

Approximate

 

 

 

 

 

Operating Weights

Input

 

CFM (m3/min)

 

Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

A (cm)

B

B (cm)

 

C

C (cm)

Lbs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60 (17.6)

 

1200 (34.0)

 

A

14 1/2

36.8

13 1/2

34.3

 

10.3

26.2

94

80 (23.4)

 

1200 (34.0)

 

B

17 1/2

44.4

16 1/2

41.9

 

11.8

29.9

103

80 (23.4)

 

1600 (45.3)

 

C

21

53.3

20

50.8

 

13.6

34.5

114

100 (29.3)

 

1600 (45.3)

 

C

21

53.3

20

50.8

 

13.6

34.5

118

100 (29.3)

 

2000 (56.6)

 

C

21

53.3

20

50.8

 

13.6

34.5

122

120 (35.1)

 

2000 (56.6)

 

C

21

53.3

20

50.8

 

15.8

40.1

129

SECTION III: FILTERS

FILTER INSTALLATION

All applications require the use of a field installed filter. All filters and mounting provision must be field supplied.

Filters must be installed external to the furnace cabinet. DO NOT

attempt to install filters inside the furnace.

Table 4: Recommended Filter Sizes (High Velocity 600 FPM)

CFM

Cabinet

Side

Bottom

(m³/min)

Size

(in)

(in)

1200 (34.0)

A

16 x 25

14 x 25

1200 (34.0)

B

16 x 25

16 x 25

1600 (45.3)

C

16 x 25

20 x 25

2000 (56.6)

C

(2) 16 x 25

20 x 25

NOTES:

1.Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters.

2.Do not exceed 1800 CFM using a single side return and a 16x25 filter. For CFM greater than 1800, you may use two side returns or one side and the bottom or one side return with a transition to allow use of a 20x25 filter.

SIDE RETURN

Locate the “L” shaped corner locators. These indicate the size of the cut- out to be made in the furnace side panel. Refer to Figure 15.

Front of

Furnace

Side of

Furnace

Corner

Markings

FIGURE 15: Side Return Cutout Markings

Install the side filter rack following the instructions provided with that accessory. If a filter(s) is provided at another location in the return air system, the ductwork may be directly attached to the furnace side panel.

Some accessories such as electronic air cleaners and pleated media may require a larger side opening. Follow the instructions supplied with that accessory for side opening requirements. Do not cut the opening larger than the dimensions shown in Figure 14.

Johnson Controls Unitary Products

9

Page 9
Image 9
Johnson Controls LP8C/LPLC*MP, YP8C/YPLC*MP, TP8C/TPLC*MP Section III Filters, Filter Installation, Side Return, Btuh kW