Johnson Controls CP8C/CPLC*MP, YP8C/YPLC*MP, LP8C/LPLC*MP, TP8C/TPLC*MP UIM-B-1008

Models: YP8C/YPLC*MP TP8C/TPLC*MP LP8C/LPLC*MP CP8C/CPLC*MP

1 32
Download 32 pages 6.92 Kb
Page 15
Image 15

368262-UIM-B-1008

THERMOSTAT

*PP11C70224

 

ID MODELS

 

 

 

TP(8,L)C

 

 

 

 

YP(8,L)C

 

 

 

 

CP(8,L)C

 

 

 

 

LP(8,L)C

 

 

 

 

 

 

 

 

 

 

 

MODULATING

 

 

TWO STAGE

 

 

 

AIR

 

FURNACE

 

 

 

 

 

CONDITIONER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

Full Stage Compressor

RH

24 – Volt Hot

(Heat XFMR)

G

Fan

RC

24 – Volt Hot

(Cool XFMR)

 

W

 

 

 

 

Full Stage Heat

 

 

 

 

 

 

 

 

 

HM1

 

 

 

 

Humidistat

 

 

 

 

 

 

 

 

 

 

 

 

 

2

External Humidistat

 

 

 

(Optional)

 

 

 

 

 

 

 

 

Open on Humidity Rise

 

 

 

 

 

 

 

MODULATING

FURNACE CONTROL

C

24 – Volt Common

Y1

Single

Stage Compressor

R

24 – Volt Hot

G

Fan

W

Modulating Heat

Y/Y2

Second or Full

Stage Compressor

O

Reversing Valve

Energized in Cool

LO COMP

Single Stage

Compressor (OUT)

HI COMP

Second Stage

Compressor (OUT)

DHUM

Dehumidification-

Open on Humidity Rise

1

C

24 – Volt Common

Y1

First Stage Compressor

R

24 – Volt Hot

Y2

Second Stage

Compressor

Clipping Jumper W914 for electric heat on thermostat is not necessary

2Part Number:

S1-2HU16700124

Move HUMIDISTAT

jumper to “YES”

if humidistat is to be used.

Part Numbers:

1

SAP = Legacy

FIGURE 21: Thermostat Chart - Two Stage Air Conditioner with Single Stage Thermostat – Variable Speed or PSC Modulating Furnace

Johnson Controls Unitary Products

15

Page 15
Image 15
Johnson Controls CP8C/CPLC*MP, YP8C/YPLC*MP, LP8C/LPLC*MP, TP8C/TPLC*MP installation manual UIM-B-1008