In order to comply with the 10BASE-T standard, ports designed for workstation connections have been marked with the graphical symbol ‘x’. This denotes a crossover in the port’s internal wiring, for example 1x, 2x, 3x...

Hub Connections

If you have additional hubs you want to connect using 10BASE-2 (Coax), you need:

One 10BASE-2 50 Ohm cable for each additional hub. The minimum cable length you can use is 0.5 meters (1.6 feet). The maximum segment length you can have is 185 meters (607 feet).

One 10BASE-2 ‘Y’ piece for each hub. You can use ‘T’ pieces but ‘Y’ pieces provide adequate clearance of the other ports.

Two 10BASE-2 50 Ohm terminators (end pieces).

If you have additional hubs you want to connect using 10BASE-T, you need:

One ‘Straight-through’ 10BASE-T cable for each additional hub.

Positioning the OfficeConnect Hub

2-5

Positioning the OfficeConnect Hub

When installing your OfficeConnect hub, ensure:

It is out of direct sunlight and away from sources of heat.

Cabling is away from power lines and fluorescent lighting fixtures, and sources of electrical noise such as radios, transmitters and broadband amplifiers.

Water or moisture cannot enter the case of the unit.

Air flow around the unit and through the vents in the side of the case is not restricted. We recommend you provide a minimum of 25.4 mm (1 in) clearance.