Important Safety Information

60APPENDIX A: SAFETY INFORMATION

Important Safety Information

WARNING: Installation and removal of the unit must be carried out by qualified personnel only.

WARNING: If installing the Switch 4200 Series unit in a stack with SuperStack II or SuperStack 3 units that are narrower than the 4200 Series, the Switch 4200 Series unit must be installed below the narrower units.

WARNING: The unit must be earthed (grounded).

WARNING: Connect the unit to an earthed power supply to ensure compliance with safety standards.

WARNING: Power Cord Set:

This must be approved for the country where it is used:

U.S.A. and Canada

United Kingdom only

The cord set must be UL-approved and CSA certified.

The minimum specification for the flexible cord is: No. 18 AWG

Type SV or SJ 3-conductor

The cord set must have a rated current capacity of at least 10A.

The attachment plug must be an earth-grounding type with a NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A, 250V) configuration.

The supply plug must comply with BS1363 (3-pin 13 amp) and be fitted with a 5A fuse which complies with BS1362.

The mains cord must be <HAR> or <BASEC> marked and be of type H03VVF3GO.75 (minimum).

Europe only:

The supply plug must comply with CEE 7/7 (“SCHUKO”).

 

The mains cord must be <HAR> or <BASEC> marked and

 

be of type H03VVF3GO.75 (minimum).

Denmark

The supply plug must comply with section 107-2-D1,

 

standard DK2-1a or DK2-5a.

Switzerland

The supply plug must comply with SEV/ASE 1011.

WARNING: The appliance coupler (the connector to the unit and not the wall plug) must have a configuration for mating with an EN60320/IEC320 appliance inlet.