Power Supply Module

10CHAPTER 2: SYSTEM DESCRIPTION

Power Supply Module

The front panel of the power supply module has three LEDs (Figure 5). Their

Visual indicators

descriptions, colors, and functions are shown in Table 2.

 

Figure 5 Power Supply Module Front Panel

Table 2 LED State Description

Condition

AC OK (green)

DC OK (green)

Fault (Red)

 

 

 

 

All OK

Lighted

Lighted

Off

Thermal alarm

Lighted

Off

Off

(Ambient)

 

 

 

Thermal alarm (fan fail)

Lighted

Off

Lighted

Blown AC fuse in unit

Lighted

Off

Lighted

Low or no AC > 15mS

Off

Off

Off

(single unit)

 

 

 

AC not present in any

Off

Off

Off

power supply module

 

 

 

Over Voltage Latched

Lighted

Off

Lighted

shutdown

 

 

 

Any internal failure

Lighted

Off

Lighted

 

 

 

 

System Controller

The PoE Power Rack has a system controller at the front of the chassis. Refer to

 

Figure 6.

 

Figure 6 Front Panel of the Controller

To indicate operational and alarm status, a green LED (RUN) and red LED (ALM) are located on the front panel of the PoE system controller. When the system has an alarm, such as input failure, input over-voltage or under-voltage, output over-voltage or under-voltage, power supply failure, or power supply self-protection, the red (ALM) LED will light. Once the alarm status is cleared, the LED goes off.

The system controller of the PoE Power Rack has two major functions: