Cable Requirement

The Ethernet ports on the access point cannot accept a Category 5 cable that has an uneven sheath such as the one shown in the figure below. The RJ-45 connector on the cable will not seat properly in the receptacle on the access point. Use a Category 5 cable with an even sheath instead.

Uneven sheath

Suspended Ceiling — Flush Ceiling Tiles

This procedure applies to T-bars that are 23.9 mm (15/16 inches) wide. For a 14.2-mm (9/16-inch) or 15.9-mm (5/8-inch) T-bar, go to “Suspended Ceiling Installation — Drop Ceiling Tiles” on page 8.

Mobility

MountingMou tingtemplate

MountingMountingbracket

AP3750 access point

 

 

point

template

bracket

1Use the mounting template to cut a hole for the Category 5 cable.

2Remove the mounting bracket from the access point.