3M 2210E manual Locating Ems Markers, Locating Markers while Tracing Cable Path

Models: 2210E

1 16
Download 16 pages 27.48 Kb
Page 12
Image 12
LOCATING EMS MARKERS

LOCATING EMS MARKERS

EMS markers may be detected and located using either the 3M Dynatel2205 or 2206 EMS Marker Locating Accessory. To attach the accessory, slide the Receiver horizontally into the EMS Marker Locating Accessory mounting slot. Make sure the locking button holds the Receiver securely in the slot. To separate the units, press the locking button down and slide the Receiver out of the EMS Marker Locating Accessory mounting slot.

Locating Markers while Tracing Cable Path

To detect markers while tracing the cable path, set the 2205 or 2206 accessory mode switch to the Alert position, and trace the cable path normally. The internal buzzer in the accessory will alert you to the proximity of a detected marker.

Locating Markers using the Receiver

If the buzzer response is too broad, the exact marker position may be pinpointed by using the Receiver.

Select 577 Hz or 33 kHz on the Accessory. Use a different frequency from the tracing signal.

Turn the Receiver ON and set the frequency to match the Accessory setting.

Note: The initial Receiver gain in Peak mode is optimized for interfacing with the 2205 or 2206 Accessory while searching for a marker. Press Locating Markers while Tracing Cable Path only when a marker is detected and the signal is too strong. To search for a new marker, reset the Receiver gain to the initial setting by turning its power OFF and back ON.

Refer to the EMS Marker Locating Accessory operating instructions for further information.

Page 11

Page 12
Image 12
3M 2210E manual Locating Ems Markers, Locating Markers while Tracing Cable Path, Locating Markers using the Receiver